Emerson

Emerson PR6426/000-131 CON041/916-200 Eddy Current Sensor System

SKU PR6426/000-131 CON041/916-200

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Emerson

  • Product No.: PR6426/000-131 CON041/916-200

  • Country of origin:United States

  • Product Type: Eddy Current Sensor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 960g

  • Dimensions: 4.1cm x 15.9cm x 10.8cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Emerson PR6426/000-131 non-contact eddy current sensor operates in combination with the CON041/916-200 signal converter to form a proximity measurement system for heavy industrial turbomachinery. Engineered for deployment on steam, gas, and hydro turbines, as well as compressors, pumps, and fans, this assembly measures radial and axial shaft displacement, position, eccentricity, and motion. The PR6426/000-131 sensor monitors physical shaft proximity without direct contact, while the CON041/916-200 converter processes these variables into normalized electrical outputs suitable for continuous machinery protection networks.

Features

  • Non-contact eddy current measurement mechanism for detailed shaft dynamics and displacement tracking 
  • High-pressure durability with a sensor head rated to withstand up to 6,500 hpa 
  • Extended measurement range up to 20.0mm when paired with the designated configuration converter 
  • Rugged physical construction featuring a stainless steel sleeve and high-temperature PTFE cable insulation 
  • Fast loop processing execution defined by a signal rise time under 15 microseconds 

Applications

  • Radial and axial shaft dynamic displacement logging 
  • Industrial turbomachinery position, motion, and eccentricity monitoring 
  • Machinery protection monitoring across turbines, compressors, and large industrial fans 

Ordering Information

Model Number Sensor Type Measuring Range Linearity Error
CON041/916-200 PR6426 20.0mm (Extended Range) <= 2.5% 

Technical Specifications

Dynamic & Performance Specifications

Parameter Specification
Frequency Range (-3 dB) 0 to 20,000 Hz 
Rise Time <15 us 
Sensor Sensitivity 2 V/mm (50.8 mV/mil) <= +/-1.5% max 
Air Gap (Center) Approx. 5.5 mm (0.22") Nominal 
Long Term Drift <0.3% 
Maximum Surface Speed 2,500 m/s (98,425 ips) 
Target / Surface Material Ferromagnetic Steel (42 Cr Mo 4 Standard) 
Target Shaft Diameter >= 200 mm (7.87") 

Electrical & Power Specifications

Parameter Specification
Supply Voltage Range (-24V Configuration) -23V to -32V (Output Range: -4V to -20V) 
Supply Voltage Range (-2V Configuration) -21V to -32V (Output Range: -2V to -18V) 

Environmental Specifications

Parameter Specification
Converter Operating Temperature Range -30 to 100 degC (-22 to 212 Fahrenheit) 
Sensor Operating Temperature Range -35 to 175 degC (-31 to 347 Fahrenheit) 
Sensor Temperature Excursions (<4 Hours) 200 degC (392 Fahrenheit) 
Maximum Cable Temperature 200 degC (392 Fahrenheit) 
Converter Shock and Vibration 5g @ 60Hz @ 25 degC (77 Fahrenheit) 
Sensor Shock and Vibration 5g (49.05 m/s2) @ 60Hz @ 25 degC (77 Fahrenheit) 
Converter Protection Class IP20 

Physical Specifications

Parameter Specification
Manufacturer Emerson 
Converter Housing Material PA 6.6 
Converter Weight ~60 grams (2.12 oz) 
Sensor Sleeve Material Stainless Steel 
Sensor Cable Material PTFE 
Sensor Weight (with 1M Cable, No Armor) ~800 grams (28.22 oz) 

Connections/Interfaces

Connector / Terminal Function
Transducer Input Connection Self-Locking Lemo-Plug 
Supply / Output Connection Screw Terminal Type (Max. 1.5mm2, wire-end sleeves) 

Installation Guidelines

  • Install the signal converter module on a standard DIN rail carrier inside the enclosure.
  • Maintain a clear zone of at least 80 mm diameter free of ferrous material around the 32mm sensor head to avoid field distortion.
  • Observe a minimum cable bending radius of 35 mm for armored cable paths, or 25 mm for non-armored variants.
  • Calibrate the initial sensor position to a nominal center air gap of approximately 5.5 mm.

Compliance and Certifications

  • CE: 2014/30/EU (EN 61326-1), 2014/34/EU, 2011/65/EU (DIN EN 50581) 
  • ATEX: EN 60079-0, EN 60079-11; II 2 G Ex ia IIC T4 Gb (-20 degC <= Ta <= 80 degC) 
  • IEC-Ex: IEC 60079-0, IEC 60079-11, IEC 60079-26; Ex ia IIC T4 Gb (-20 degC <= Ta <= 80 degC) 
  • CSA: CAN/CSA-C22.2 NO. 0-M91, NO. 157-92, NO. 213-M1987, CAN/CSA-E60079-15-02, NO. 25-1966, NO. 61010-1-04; ANSI/UL Standard 913-2004, ANSI/UL Standard 1604-1995, UL 60079-15 2002, UL 61010-1 
  • Hazardous Area Entry: Intrinsic Safety (Ex ia IIC T4 Gb / Class I Division 1 Groups A, B, C, D T4); Non-sparking (Class I Division 2 Groups A, B, C, D / Ex nA II T3..T4 / AEx nA II T3..T4) 

FAQ

What is the maximum linear measuring range achievable with this specific sensor system combination?

When the 32mm sensor is paired with this specific converter configuration, it provides an extended linear measurement range of 20.0mm.

What is the minimum bending radius allowed for the sensor cable during installation?

The minimum allowed static bending radius is 35 mm for armored cable options and 25 mm for non-armored configurations.

What are the ambient temperature parameters certified under the intrinsic safety classifications?

For ATEX and IEC-Ex intrinsic safety zones, the device is certified for operation within an ambient temperature range of -20 degC to 80 degC.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson PR6426/000-131 CON041/916-200 Eddy Current Sensor System

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.

Magnetic Flowmeters: Commissioning and Diagnostics

A field-focused checklist for selecting, installing, commissioning, and diagnosing magnetic flowmeters, with emphasis on conductivity, full-pipe conditions, grounding, wiring, zero checks, and PLC...