Product Description

Description

The Emerson PR9350/02 is a surface contact inductive sensor designed for critical turbomachinery applications such as steam, gas, and hydro turbines, compressors, pumps, and fans. This heavy-duty displacement transducer measures radial and axial shaft dynamic displacement, position, and eccentricity under tough environmental conditions. Operating on a carrier frequency principle with center-tapped windings, the PR9350/02 provides stable position tracking and high precision for industrial machinery protection and condition monitoring.

Features

  • Surface contact inductive design optimized for shaft displacement and eccentricity tracking 
  • Robust construction tailored to survive demanding and tough industrial environments 
  • Supplied with a matching solenoid plunger featuring an integrated M3 threaded rod 
  • Equipped with a reliable electrical interface utilizing an ITT Cannon connector 

Applications

  • Radial and axial shaft dynamic displacement measurement 
  • Turbomachinery shaft position and eccentricity monitoring 
  • Critical protection loops for gas, steam, and hydro turbines 
  • Structural or displacement monitoring on large industrial compressors, pumps, and fans 

Ordering Information

Model Number Range Sensitivity Linearity Error
PR9350/02 +25 mm 270 mV/V 3.5%

Technical Specifications

Performance & Dynamic Performance

Parameter Specification
Measurement Range +25 mm 
Sensitivity 270 mV/V 
Linearity Error 3.5% 

Electrical Specifications

Parameter Specification
Supply Voltage 5 Vrms 
Carrier Frequency 3 to 5 kHz 
Capacitance 250 pF (each winding) 

Environmental Specifications

Parameter Specification
Operating Temperature Range -20 to 100 degC (-4 to 212 Fahrenheit) 
Temperature Error <3% 

Physical & Mechanical Specifications

Parameter Specification
Manufacturer Emerson 
Weight 255 grams 
Dimension A 108 mm 
Dimension B 127 mm 
Dimension C (with core slug in nominal center or zero position) 65.4 mm 
Dimension D 76.2 mm 
Dimension E 123.2 mm 
Dimension F 25.4 mm 
Maximal Diameter 25 mm 
Fixing Holes M4 
Plunger Thread M3 

Connections/Interfaces

Connector / Terminal Function
Cannon Connector CA06COME10SL3S44 Electrical interface connection mapping to internal center tapped windings 

Installation Guidelines

  • Use the integrated M4 fixing holes to securely mount the housing block to a stable reference point on the machine casing.
  • Ensure proper mechanical alignment of the solenoid plunger with the M3 threaded rod during setup.
  • Align the core slug to match dimension C (65.4 mm) relative to the sensor frame to reference the true nominal center or zero position.
  • Verify that the carrier frequency of the driver electronics is configured between 3 and 5 kHz to preserve sensitivity and accuracy requirements.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What components are included as standard accessories with the device?
The device includes a solenoid plunger equipped with an M3 threaded rod, along with an ITT Cannon connector (model CA06COME10SL3S44).
What is the certified operating temperature range for the sensor?
The operating temperature range for the device spans from -20 degC to 100 degC (-4 to 212 Fahrenheit).
What electrical carrier frequency range is required to operate this sensor?
The sensor requires an electrical supply with a carrier frequency between 3 and 5 kHz.
Reviews

PR9350/02

Stock &amp; lead time on request

Call
1 of 3

Emerson PR9350/02 AMS Inductive Sensor

Only 2 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: PR9350/02

  • Country of origin:United States

  • Product Type: Inductive Sensor

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 255g

  • Dimensions: 108 mm x 127 mm x 65.4 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Emerson PR9350/02 is a surface contact inductive sensor designed for critical turbomachinery applications such as steam, gas, and hydro turbines, compressors, pumps, and fans. This heavy-duty displacement transducer measures radial and axial shaft dynamic displacement, position, and eccentricity under tough environmental conditions. Operating on a carrier frequency principle with center-tapped windings, the PR9350/02 provides stable position tracking and high precision for industrial machinery protection and condition monitoring.

Features

  • Surface contact inductive design optimized for shaft displacement and eccentricity tracking 
  • Robust construction tailored to survive demanding and tough industrial environments 
  • Supplied with a matching solenoid plunger featuring an integrated M3 threaded rod 
  • Equipped with a reliable electrical interface utilizing an ITT Cannon connector 

Applications

  • Radial and axial shaft dynamic displacement measurement 
  • Turbomachinery shaft position and eccentricity monitoring 
  • Critical protection loops for gas, steam, and hydro turbines 
  • Structural or displacement monitoring on large industrial compressors, pumps, and fans 

Ordering Information

Model Number Range Sensitivity Linearity Error
PR9350/02 +25 mm 270 mV/V 3.5%

Technical Specifications

Performance & Dynamic Performance

Parameter Specification
Measurement Range +25 mm 
Sensitivity 270 mV/V 
Linearity Error 3.5% 

Electrical Specifications

Parameter Specification
Supply Voltage 5 Vrms 
Carrier Frequency 3 to 5 kHz 
Capacitance 250 pF (each winding) 

Environmental Specifications

Parameter Specification
Operating Temperature Range -20 to 100 degC (-4 to 212 Fahrenheit) 
Temperature Error <3% 

Physical & Mechanical Specifications

Parameter Specification
Manufacturer Emerson 
Weight 255 grams 
Dimension A 108 mm 
Dimension B 127 mm 
Dimension C (with core slug in nominal center or zero position) 65.4 mm 
Dimension D 76.2 mm 
Dimension E 123.2 mm 
Dimension F 25.4 mm 
Maximal Diameter 25 mm 
Fixing Holes M4 
Plunger Thread M3 

Connections/Interfaces

Connector / Terminal Function
Cannon Connector CA06COME10SL3S44 Electrical interface connection mapping to internal center tapped windings 

Installation Guidelines

  • Use the integrated M4 fixing holes to securely mount the housing block to a stable reference point on the machine casing.
  • Ensure proper mechanical alignment of the solenoid plunger with the M3 threaded rod during setup.
  • Align the core slug to match dimension C (65.4 mm) relative to the sensor frame to reference the true nominal center or zero position.
  • Verify that the carrier frequency of the driver electronics is configured between 3 and 5 kHz to preserve sensitivity and accuracy requirements.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson PR9350/02 AMS Inductive Sensor

What components are included as standard accessories with the device?

The device includes a solenoid plunger equipped with an M3 threaded rod, along with an ITT Cannon connector (model CA06COME10SL3S44).

What is the certified operating temperature range for the sensor?

The operating temperature range for the device spans from -20 degC to 100 degC (-4 to 212 Fahrenheit).

What electrical carrier frequency range is required to operate this sensor?

The sensor requires an electrical supply with a carrier frequency between 3 and 5 kHz.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...