The Emerson PR9350/02 is a surface contact inductive sensor designed for critical turbomachinery applications such as steam, gas, and hydro turbines, compressors, pumps, and fans. This heavy-duty displacement transducer measures radial and axial shaft dynamic displacement, position, and eccentricity under tough environmental conditions. Operating on a carrier frequency principle with center-tapped windings, the PR9350/02 provides stable position tracking and high precision for industrial machinery protection and condition monitoring.
| Model Number | Range | Sensitivity | Linearity Error |
|---|---|---|---|
| PR9350/02 | +25 mm | 270 mV/V | 3.5% |
| Parameter | Specification |
|---|---|
| Measurement Range | +25 mm |
| Sensitivity | 270 mV/V |
| Linearity Error | 3.5% |
| Parameter | Specification |
|---|---|
| Supply Voltage | 5 Vrms |
| Carrier Frequency | 3 to 5 kHz |
| Capacitance | 250 pF (each winding) |
| Parameter | Specification |
|---|---|
| Operating Temperature Range | -20 to 100 degC (-4 to 212 Fahrenheit) |
| Temperature Error | <3% |
| Parameter | Specification |
|---|---|
| Manufacturer | Emerson |
| Weight | 255 grams |
| Dimension A | 108 mm |
| Dimension B | 127 mm |
| Dimension C (with core slug in nominal center or zero position) | 65.4 mm |
| Dimension D | 76.2 mm |
| Dimension E | 123.2 mm |
| Dimension F | 25.4 mm |
| Maximal Diameter | 25 mm |
| Fixing Holes | M4 |
| Plunger Thread | M3 |
| Connector / Terminal | Function |
|---|---|
| Cannon Connector CA06COME10SL3S44 | Electrical interface connection mapping to internal center tapped windings |
Global Express Shipping
Returns & Warranty



The Emerson PR9350/02 is a surface contact inductive sensor designed for critical turbomachinery applications such as steam, gas, and hydro turbines, compressors, pumps, and fans. This heavy-duty displacement transducer measures radial and axial shaft dynamic displacement, position, and eccentricity under tough environmental conditions. Operating on a carrier frequency principle with center-tapped windings, the PR9350/02 provides stable position tracking and high precision for industrial machinery protection and condition monitoring.
| Model Number | Range | Sensitivity | Linearity Error |
|---|---|---|---|
| PR9350/02 | +25 mm | 270 mV/V | 3.5% |
| Parameter | Specification |
|---|---|
| Measurement Range | +25 mm |
| Sensitivity | 270 mV/V |
| Linearity Error | 3.5% |
| Parameter | Specification |
|---|---|
| Supply Voltage | 5 Vrms |
| Carrier Frequency | 3 to 5 kHz |
| Capacitance | 250 pF (each winding) |
| Parameter | Specification |
|---|---|
| Operating Temperature Range | -20 to 100 degC (-4 to 212 Fahrenheit) |
| Temperature Error | <3% |
| Parameter | Specification |
|---|---|
| Manufacturer | Emerson |
| Weight | 255 grams |
| Dimension A | 108 mm |
| Dimension B | 127 mm |
| Dimension C (with core slug in nominal center or zero position) | 65.4 mm |
| Dimension D | 76.2 mm |
| Dimension E | 123.2 mm |
| Dimension F | 25.4 mm |
| Maximal Diameter | 25 mm |
| Fixing Holes | M4 |
| Plunger Thread | M3 |
| Connector / Terminal | Function |
|---|---|
| Cannon Connector CA06COME10SL3S44 | Electrical interface connection mapping to internal center tapped windings |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|