Product Overview

The IC670CHS002 (IC670-CHS-002) is a high-density, box-style terminal block connector base designed for the GE Fanuc Field Control I/O system. This base serves as the critical physical and electrical interface between the field wiring and the I/O modules, providing a robust termination point for industrial sensors and actuators. Engineered for high-availability environments, the IC670CHS002 allows for "Permanent Wiring," which enables maintenance teams to replace I/O modules without disconnecting any field wires, significantly reducing Mean Time to Repair (MTTR). Its compact, rugged design is ideal for distributed I/O architectures in power generation, material handling, and large-scale manufacturing where reliable signal integrity is paramount.

Technical Configuration

The IC670CHS002 features a 36-terminal box-style connector, optimized for organized and secure wire management. It is designed to be mounted on a standard DIN rail or directly to a backpanel within an enclosure. The base includes an internal bus interface that links the I/O module to the Bus Interface Unit (BIU), facilitating seamless data exchange. This specific model supports a wide range of digital and analog Field Control modules, providing the mechanical support and electrical isolation necessary for stable operation in electrically noisy industrial environments.

Technical Specifications

Attribute Specification
Model IC670CHS002
Brand GE Fanuc / Emerson
Series Field Control I/O
Type Terminal Block Connector Base (Box Style)
Number of Terminals 36
Mounting Type DIN Rail or Backpanel
Wire Gauge 14 AWG to 22 AWG (Typical)
Voltage Rating Up to 250 VAC / VDC
Current Rating 2 Amps per terminal (Max)
Dimensions 13.5 x 4.5 x 5.2 cm
Weight 0.28 kg

Technical FAQs

What is the difference between the IC670CHS002 and the IC670CHS001?

The IC670CHS002 is a box-style terminal block, which provides a more enclosed and protected termination environment compared to the IC670CHS001 barrier-style base. The box style is often preferred for finer gauge wiring and high-density signal layouts.

Can I use this base with any Field Control I/O module?

The IC670CHS002 is compatible with the majority of Field Control digital and analog I/O modules. However, you must verify that the specific module’s pinout matches the 36-terminal configuration of this base and that the mechanical keying is properly aligned.

How does this base support system maintenance?

Because the field wiring is terminated at the base rather than the module, the I/O module can be unplugged and replaced while the wiring remains intact. This eliminates the risk of wiring errors during a module swap.


Engineering & Installation Guide

  • Wiring Discipline: When terminating wires into the 36-terminal box, ensure that each wire is stripped to the correct length (approx. 8 mm) to avoid exposed conductors or poor contact. Use ferrules for stranded wire to prevent fraying and potential short circuits between adjacent terminals.

  • Mechanical Keying: Each Field Control module and base set should be keyed to prevent the wrong module type from being inserted. Before snapping the I/O module into the IC670CHS002, check that the plastic keying tabs are set correctly to match the module’s function (e.g., Digital Input vs. Analog Output).

  • Grounding for Analog Signals: If using this base for analog modules, ensure the cable shields are properly landed on the designated ground terminals. To prevent ground loops, terminate the shield at the base end only and keep the field-side shield floating.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.