General Electric

GE Fanuc VersaMax IC200ALG620 4-Channel RTD Input Module

SKU IC200ALG620

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: IC200ALG620

  • Country of origin:United States

  • Product Type: RTD Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The IC200ALG620 (IC200-ALG-620) is a high-precision, 4-channel analog input module designed specifically for Resistance Temperature Detectors (RTD). Part of the GE VersaMax I/O family, this module provides direct interfacing for temperature sensors without the need for external signal transmitters. It is engineered to support a wide array of RTD types, including Platinum, Nickel, and Copper sensors, as well as resistance inputs. With its 16-bit resolution, the IC200ALG620 is an essential component for high-accuracy thermal monitoring in climate control systems, chemical reactor vessels, and food processing pasteurization loops. Its compact, modular design allows for decentralized placement, reducing expensive specialized wiring runs by digitizing temperature data close to the source.

Technical Configuration

The module supports 2-wire, 3-wire, and 4-wire RTD configurations, providing maximum flexibility for different lead-wire compensation requirements. It features a 16-bit A/D converter that delivers exceptional granularity, allowing the controller to detect minute thermal shifts. The VersaMax architecture enables the electronics to reside on a terminal base (sold separately), which supports "Permanent Wiring"—meaning the module can be hot-swapped without disturbing the sensor field wiring. The IC200ALG620 includes internal diagnostics to detect "Open Wire" or "Short Circuit" conditions on a per-channel basis, with front-facing LED indicators for "OK" and "User Power" status.

Technical Specifications

Attribute Specification
Model IC200ALG620
Brand GE Fanuc / Emerson
Series VersaMax Analog I/O
Input Type RTD (Pt, Ni, Cu) / Resistance
Number of Channels 4
Resolution 16-bit
RTD Types Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Cu10
Resistance Range 0 to 500 Ohms / 0 to 3000 Ohms
Accuracy +/- 0.1% to 0.5% (depending on sensor type)
Update Rate 20 ms to 80 ms per channel (configurable)
External Power Supply 24 VDC (+/- 15%)
Weight Approx. 0.13 kg

Technical FAQs

Does this module support both Celsius and Fahrenheit?

The module reports data in counts or tenths of a degree. The conversion to Celsius or Fahrenheit is typically handled in the PLC hardware configuration (Proficy Machine Edition) or via a scaling block in the logic.

What is the benefit of using 3-wire or 4-wire wiring?

2-wire setups are prone to errors caused by the resistance of the lead wires. 3-wire wiring (the industrial standard) compensates for lead resistance, while 4-wire wiring provides the highest precision by completely eliminating lead-wire resistance effects from the measurement.

Can I mix different RTD types on the same module?

Yes. Through the software configuration, each of the four channels can be independently set to a different RTD type (e.g., Channel 1 as Pt100, Channel 2 as a 0-500 Ohm resistance input).


Engineering & Installation Guide

  • Terminal Base Selection: This module requires a terminal base such as the IC200TBT002 (Barrier style) or IC200TBP002 (Spring style). Ensure the base is correctly keyed to the "Analog" position to prevent incorrect module insertion.

  • Lead-Wire Compensation: For 3-wire and 4-wire installations, ensure all lead wires are of the same gauge and length. Significant differences in wire resistance between the "Excitation" and "Sense" lines can introduce a temperature offset that the module cannot automatically cancel out.

  • Shielding for Low-Voltage Signals: RTD signals are millivolt-level and highly sensitive to noise. Always use shielded twisted-pair cable. Terminate the shield at the PLC terminal base ground and never ground the shield at the sensor end to avoid ground loops that could cause "Signal Wander."

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.