1 of 3

GE IS200WEORG1A Mark VIe Speedtronic Wind Turbine Output Board

GE IS200WEORG1A Mark VIe Speedtronic Wind Turbine Output Board

Only 5 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS200WEORG1A

  • Country of origin:United States

  • Product Type: Wind Turbine Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 380g

  • Dimensions: 28cm x 12.6cm x 3.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The IS200WEORG1A is a specialized wind turbine output board designed by GE Energy for integration within the Mark VIe Speedtronic turbine control platform. Operating explicitly as an output and power transfer assembly within wind turbine drive systems, this component distributes local signal paths and conditions auxiliary power lines. The IS200WEORG1A features integrated high-voltage overcurrent protection circuits, heavy-duty filtering components, and clear component designation layout structures to interface directly with wind turbine drive operations.

Features

  • High-Temperature Filtering Subsystem: Equipped with two Nichicon 270uF 150 Celsius electrolytic capacitors to maintain electrical line stability in high-temperature environments.
  • Overvoltage Transient Protection: Includes an orange-coated 3kV single-layer ceramic capacitor positioned near the primary filter elements to buffer voltage spikes.
  • Dual-Tier Overcurrent Protection: Populated with five heavy-duty circuit protection fuses, divided between 250V rated lines and 3 dedicated 600V protection circuits.
  • Precision Power Transfer Balancing: Integrates onboard transformers engineered to safely isolate and transfer power lines to auxiliary system boards.
  • Onboard Jumper Control: Features accessible jumper links labeled J4 and J5 to allow tailored circuit configurations by the system field engineer.

Applications

  • Mark VIe Wind turbine drive assembly monitoring
  • Power distribution and output isolation networks within alternative energy setups
  • Auxiliary power routing and control cabinets

Technical Specifications

Item Description / Value
Manufacturer GE Energy
Series Mark VIe Speedtronic
Part Number IS200WEORG1A
Functional Acronym WEOR
Functional Description GE Printed Circuit Board
PCB Coating Normal Coating
Functional Revision 1 A
High-Current Resistor Specifications 100 Ohm (Resistors 1, 2, 3, 5, 8, and 9)
Total Resistors 15 total
High-Temperature Capacitors (C1, C3) Nichicon 270uF, 150 Celsius
Surge Capacitor (C2) 3kV Single Layer Ceramic
Maximum Source Supply Label FROM 230L-N SOURCE 250VA MAX

Installation Guidelines

  • Crimp Clearance Standards: Maintain the specified factory crimp clearances between the high-power resistors (R1, R2, R3, R5, R9) and the underlying circuit surface to ensure heat dissipation and electrical isolation.
  • Chassis Attachment: Utilize the 5 factory-drilled mounting holes along the board framework to securely anchor the unit onto the enclosure panel plate.
  • Handling Protocols: Always discharge static build-up and utilize an ESD-safe matting surface before manipulating configuration jumpers J4 or J5.

What is the purpose of the specific crimp clearance layout on the device?

Crimp clearance defines the exact safety spacing between the base of high-power resistors and the board surface to maintain optimal thermal isolation and prevent arc-over conditions.

How many high-voltage protection fuses are located on this assembly?

The board features a total of five fuses, which include three 600V rated fuses alongside 250V rated circuit protection elements.

Are the power isolation circuits on this board capable of interfacing with external cards?

Yes, the device contains onboard power transformers specifically designed to securely step or transfer electrical loads from this module to auxiliary target boards.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Recently Viewed Products

Technical knowledge

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...