Description

The GE Multilin UR-8AH is an analog AC measurement interface module developed for the Universal Relays platform that provides three 1A/5A Phase CTs, one 1A/5A Ground CT, and 4 VTs to step down primary electrical grid signals into precise secondary values. This configuration allows the hosting relay chassis to sample, meter, and monitor crucial utility parameters including current, voltage, active power, energy, frequency, and circuit demand factors.

The primary function of the UR-8AH is to act as an isolated instrument transformer interface, converting high-magnitude high-voltage system lines into lower operational signals that can be recognized and modulated by the internal processing logic. As a legacy hardware option, it is engineered to operate on legacy equipment tiers carrying firmware version 3.5x or earlier, establishing standard 4CT/4VT matching layouts. This module provides critical safety isolation between secondary instrument circuits and ground, delivering accurate data streams used by protection loops to isolate faulted primary components. All parameter adjustments, calibration thresholds, and trend logs are interfaced using General Electric Multilin's EnerVista UR workstation software.

Features

  • Standard 4CT/4VT Interface Layout: Features three 1A/5A phase current inputs, one 1A/5A ground current input, and 4 voltage transformer paths.
  • Legacy Firmware Support: Optimized for legacy UR installations running firmware version 3.5x or lower.
  • High-Accuracy Parameter Metering: Delivers secondary sensing resolution for voltage, current, power, energy, and grid frequency metrics.
  • EnerVista Software Configuration: Combines with EnerVista UR interfaces for streamlined data export, trending, and graphical parameter review.

Applications

  • Substation Feeder Monitoring: Deployed inside traditional utility panels to capture current and voltage waveforms across key distribution circuits.
  • Legacy Protective Relay Upgrades: Installed within retrofitted configurations to replace faulty analog acquisition cards in legacy UR relay groups.
  • Industrial Electrical Plant Safeguards: Measures transformer and large electrical distribution loops to supply continuous utility data to central automation networks.

Technical Specifications

Parameter Specification
Manufacturer GE Multilin
Model UR-8AH
Product Series UR Series (Universal Relay)
Module Type CT/VT Module
Phase Current Transformer Channels 3 Channels (1A/5A Dual Rated)
Ground Current Transformer Channels 1 Channel (1A/5A Dual Rated)
Voltage Transformer Channels 4 Channels (VTs)
Firmware Compatibility Version 3.5x or earlier
Configuration Tool EnerVista UR
Manufacturing Location Ontario, Canada
Dimensions approx. 15cm L x 18cm W x 4cm H
Weight 2 lb, 9 oz (approx. 1.16 kg)

Installation Guidelines

  • Primary Circuit Isolation: Prior to removing or installing the module, disconnect and isolate all primary and secondary power lines from the relay case. Short-circuit all external CT secondary lines to avoid high-voltage transients.
  • Electrostatic Grounding Procedures: Technicians must utilize a grounded ESD wrist strap when inserting or removing this analog instrumentation card to safeguard embedded analog-to-digital processing components.
  • CPU Hardware Co-linking: Ensure this legacy card is paired with compatible legacy processing components such as the UR-9A, UR-9C, or UR-9D CPU cards.
  • Chassis Attachment: Slide the assembly straight along the dedicated enclosure chassis guide slots until the analog terminal headers align properly with the rear backplane assembly. Fasten faceplate locking screws tightly.

FAQ

What firmware range is supported by the UR-8AH module configuration?

This legacy analog interface card is designed to accept and operate with relay firmware version 3.5x or earlier.

Which specific CPU models should be paired with the UR-8AH analog card?

The module should be matched with legacy version Multilin CPU cards, including the UR-9A, UR-9C, or UR-9D modules.

What is the secondary current input rating for the CT paths on this module?

The current transformer input ports are dual-rated, accepting either a 1A or 5A secondary instrument connection.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Canada

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.