General Electric DS200TCDAH1BHE Mark V Digital I/O Board
SKU DS200TCDAH1BHE
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
General Electric
Product No.:
DS200TCDAH1BHE
Country of origin:United States
Product Type:
Digital I/O Board
Payment:
T/T, Western Union
Weight:
450g
Dimensions:
280 mm x 220 mm x 30 mm (H x W x D)
Shipping port:
Xiamen
Warranty:
12 months
Description
The General Electric DS200TCDAH1BHE is a Digital I/O Board developed for use in the GE Speedtronic Mark V Series turbine control systems. The DS200TCDAH1BHE processes and routes digital signals, handling contact input signals from the DTBA and DTBB terminal boards as well as contact output signals (relay/solenoid) from the TCRA boards. These signals are conditioned, time-tagged upon state changes, and transmitted over the IONET communication network to the TCQC board in cores and (if is installed) and the CTBA terminal board in . Designed for steam, gas, or wind turbine control and management applications, the board is typically installed in digital I/O cores , , and .
Features
Processes contact inputs from DTBA and DTBB terminal boards via JR and JQ connectors.
Conditions input signals and applies time-tags to state changes.
Processes contact output (relay/solenoid) signals from TCRA boards.
Transmits conditioned digital signals across the IONET network via JX1 and JX2 connectors.
Supports software-based contact signal inversion using I/O configuration constants.
Equipped with eight hardware jumpers for configuration, testing, and network setting.
Features an on-board block of 10 LEDs and a side LED for diagnostic indications.
Includes dedicated test points for manual signal probing and circuit diagnostics.
Applications
GE Speedtronic Mark V Gas Turbine Control Systems
GE Speedtronic Mark V Steam Turbine Control Systems
GE Wind Turbine Control Management Systems
Technical Specifications
Parameter
Value
Manufacturer
General Electric
Country of Manufacture
United States (USA)
Part Number
DS200TCDAH1BHE
Functional Abbreviation
TCDA
Product Type
Digital I/O Board
Series
Mark V
Coating Style
Conformal (H1)
Revision Quantity
3 Revisions (B, H, E)
System Location Cores
, ,
Diagnostic Elements
1 side LED, 1 block of 10 LEDs, test points
Connections/Interfaces
Connector Pin
Function
JP
Distributes power from TCPS board in , , and cores to , , and cores
JQ
Connects to JQR socket on DTBA board; carries contact input signals to the board
JR
Connects to JRR socket on DTBB board; carries contact input signals to the board
JO1
Writes contact output (relay/solenoid) signals to TCRA board in location four
JO2
Writes contact output (relay/solenoid) signals to TCRA board in location five
JX1
Shielded twisted pair connector for IONET signals
JX2
Shielded twisted pair connector for IONET signals
Installation Guidelines
IONET Termination: Set jumpers J2 and J3 to control IONET termination resistors based on network topology requirements.
Board Identification: Configure jumpers J4, J5, and J6 to set the unique IONET ID for proper network addressing and communication.
System Functions: Set jumper J7 to enable or disable the stall timer function according to specific system control needs.
Factory Settings: Keep jumpers J1 and J8 in their default factory positions unless executing specific test procedures.
Signal Probing: Utilize calibrated test probes compatible with the board test points when analyzing circuit voltage or verifying input/output signals.
Thermal Protection: Maintain adequate enclosure cooling, as thermal trip protection automatically shuts down the drive system upon detecting an interior over-temperature condition.
FAQ
What is the General Electric DS200TCDAH1BHE used for?
The General Electric DS200TCDAH1BHE is a Digital I/O Board used to process and route contact input and output signals within GE Speedtronic Mark V turbine control systems.
Which terminal boards connect to the DS200TCDAH1BHE for input signals?
The board receives contact input signals from the DTBA and DTBB terminal boards via the JQ and JR connectors.
What are the jumper functions on the DS200TCDAH1BHE?
Jumpers J2 and J3 control IONET termination resistors, J4 through J6 set the board IONET ID, J7 enables the stall timer, and J1 and J8 are reserved for factory testing.
How does the DS200TCDAH1BHE transmit conditioned data across the system?
The board transmits conditioned and time-tagged contact input signals over the IONET communication network using the shielded twisted pair JX1 and JX2 connectors.
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.