The General Electric IC200BEM104 is a VersaMax Actuator-Sensor Interface (ASI) Network Master Module designed to integrate seamlessly into the VersaMax modular control system. This specialized communication module functions as an AS-Interface master, providing efficient, cost-effective data exchange between the programmable controller and lower-level binary actuators and sensors in industrial automation architectures.

Engineered to support industrial networking standards, the IC200BEM104 simplifies system wiring by multiplexing power and data over a single unshielded two-conductor cable. It streamlines machine-level communication, reduces installation time, and enhances diagnostic capabilities across discrete automation tasks.

Features

  • Conforms to the AS-Interface Specification for standard master protocol operations
  • Supports communication with up to 31 slave devices on a single AS-Interface network loop
  • Exchanges up to 4 bits of input data and 4 bits of output data per individual slave address
  • Integrates directly into the VersaMax rack system without requiring complex custom backplane configuration
  • Provides status LEDs for clear indication of module health, network status, and power conditions

Applications

  • Discrete manufacturing and assembly lines
  • Conveyor and material handling systems
  • Packaging and labeling machinery
  • Decentralized machine safety and sensor monitoring

Technical Specifications

Parameter Specification
Manufacturer General Electric
Catalog Number / SKU IC200BEM104
Product Family VersaMax
Module Type ASI Network Master Module
Maximum Slave Capacity Up to 31 AS-Interface slaves
Data Exchange Capacity 4 bits input / 4 bits output per slave address
Country of Origin United States

Connections / Interfaces

The module features front-facing terminal connections designed for direct termination of the AS-Interface two-wire bus cable, alongside internal backplane interfaces that connect directly to the VersaMax CPU and power supply carrier bases. Integrated diagnostic LEDs give operators immediate feedback regarding network traffic, power supply status, and slave communication errors.

Installation Guidelines

The IC200BEM104 mounts directly onto a standard VersaMax carrier base alongside other rack modules. Ensure that system power is disconnected before installing or removing the module. Connect the AS-Interface network cable to the designated terminals, observing correct polarity and shielding practices as outlined in the hardware manual to maintain signal integrity in electrically noisy environments.

FAQ

What system is the IC200BEM104 designed for?

The IC200BEM104 is specifically designed for the General Electric VersaMax modular control platform.

How many slave devices does this AS-Interface master support?

This module supports communication with up to 31 AS-Interface slave devices on the network loop.

What is the data exchange capacity per slave address?

The module exchanges up to 4 bits of input data and 4 bits of output data for each connected slave address.

How does the module connect to the network?

It connects via dedicated front terminals to the standard unshielded two-conductor AS-Interface cable, simplifying field device wiring.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 14 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.