Description

The GE Multilin 745-W3-P511-G51-HI-R-E is a digital, three-winding transformer protection system engineered for the primary protection, management, and control of power transformers. This high-performance device delivers comprehensive multi-winding differential protection, adaptive harmonic restraint, and extensive overcurrent protection elements within a rugged draw-out construction. It features advanced internal logic and precise high-accuracy metering to eliminate the need for extra external components or auxiliary transducers. The unit is configured with 5 A phase current inputs and 5 A ground current inputs across its winding interfaces to match specific system requirements. Outfitted with high-speed processing, comprehensive data logging, and flexible communication ports, the device interfaces seamlessly with distributed control systems (DCS) and SCADA automation architectures to monitor asset health and maintain system integrity.

Features

  • Comprehensive three-winding transformer differential protection with percentage restraint and adaptive harmonic blocking.
  • Draw-out chassis construction allowing quick unit replacement and drastically reduced system maintenance downtime.
  • Integrated high-accuracy metering functions for current, voltage, power, and frequency parameters without auxiliary equipment.
  • Advanced fault diagnostics incorporating precise sequence-of-events reporting, oscillography, and waveform capture.
  • Multiple user-programmable analog and digital inputs/outputs for extensive control and interlocking logic schemes.
  • High-speed communications supporting industrial protocols for integration into SCADA networks.
  • FlexLogic programming capabilities allowing users to customize control sequences and interlocking logic without extra hardware.
  • Front-panel enhanced user interface with an informative LCD screen and tactile keypad for straightforward configuration and diagnostic readout.

Applications

  • Primary protection and control for three-winding power transformers in utility and industrial substations.
  • Main or backup differential and overcurrent protection for auto-transformers and multi-winding generation transformers.
  • Comprehensive asset monitoring, load profiling, and transformer thermal overload tracking in power networks.
  • Advanced power system automation requiring high-speed network reporting and protective relay interlocking.

Ordering Information

Selection Code Technical Specification Description
745 Base model for Transformer Protection System
W3 Three-Winding Transformer Protection
P511 5 A Phase Current Inputs (Winding 1, Winding 2, Winding 3)
G51 5 A Ground Current Inputs (Winding 1, Winding 2)
HI 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz Power Supply
R Red Breaker Closed LED Indicator
E Enhanced Display, Larger LCD, and Improved Keypad

 

Technical Specifications

Parameter Specification
Manufacturer GE Multilin (GE Vernova)
Transformer Windings (W3) 3 Windings
Phase Current Inputs (P511) 5 A for all three windings
Ground Current Inputs (G51) 5 A for Winding 1 and Winding 2
Power Supply Option (HI) 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz
Breaker Status LED (R) Red breaker closed LED indicator
User Interface (E) Enhanced display, larger LCD, and improved keypad layout

Installation Guidelines

  • Chassis Mounting: Securely mount the draw-out chassis into the instrument panel cutout using standard hardware guidelines designated for the unit frame.
  • Grounding Protocols: Connect a dedicated, low-impedance grounding copper wire directly to the chassis ground terminal to mitigate electrical noise and protect sensitive circuitry.
  • Wiring Requirements: Route current transformer (CT) and voltage transformer (VT) connections isolated from low-voltage signal wiring and communication lines to mitigate EMI/RFI issues.
  • CT Circuit Integrity: Ensure all phase and ground current transformer secondary circuits are fully verified and safely terminated to the correct rear blocks prior to operational power-up.

FAQ

What is the function of the W3 designation in the relay model code?

The W3 designation specifies that the device is configured to support comprehensive primary differential and overcurrent protection for a three-winding power transformer.

What input current ratings do the P511 and G51 options provide?

The P511 option provides 5 A phase current inputs for all three transformer windings, while the G51 option provides 5 A ground current inputs for Winding 1 and Winding 2.

What source voltage limits are supported by the HI power supply option?

The HI power supply option operates safely over an input range of 88 to 300 VDC and 70 to 265 VAC at a frequency of 48 to 62 Hz.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.