General Electric

General Electric IC600RB752 Series Six Device Switch Module

SKU IC600RB752

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric
  • Product No.: IC600RB752
  • Origin United States
  • Product Type: Device Switch Module
  • Payment: T/T, Western Union
  • Weight: 1.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

General Electric IC600RB752 Series Six Device Switch Module

Quantity

Product Description

Description

The General Electric IC600RB752 is a specialized Device Switch Module designed for use within Series Six Redundant Processor Unit (RPU) PLC systems. This module features 12 Form C reed relays, enabling external peripherals such as printers, CRTs, and host computers to be shared seamlessly between primary and backup CPUs connected to the RPU. Accessible via a front-mounted 36-point connector, the module isolates the CPU and I/O switch modules, interfacing them securely to the Data Control Module and associated memory.

Equipped with an integrated watchdog timer and a seven-segment status display, the IC600RB752 provides immediate visual feedback for system configuration and error conditions. On-board option jumpers allow technicians to configure data transfer requirements and operational parameters to suit specific redundant automation architectures.

Features

  • 12 independent Form C reed relays for peripheral and communication line sharing
  • Front-mounted 36-point connector for secure external signal termination
  • Seven-segment LED status display for system configuration and error diagnostics
  • Watchdog timer monitoring with external error indication
  • Configurable on-board option jumpers for customized data transfer selection
  • UL listed under Standard No. 508 for industrial control equipment

Applications

  • Redundant Series Six PLC processor architectures
  • Sharing external peripherals (CRTs, printers, modems) between Master and Backup CPUs
  • Switching communication lines between redundant host computers or modems
  • Routing analog signals between redundant Master and Backup I/O chains

Technical Specifications

Parameter Specification
Manufacturer General Electric
Product Series Series Six (Redundant Processor Unit)
Catalog Number / SKU IC600RB752
Module Type Device Switch Module (Circuit Board)
Relay Type 12 Form C Reed Relays
Relay Contact Ratings 250 mA maximum current, 25V DC or AC maximum voltage, 5 ms max switch bounce (resistive loads only)
Power Requirements 5V DC, 1.5 A (supplied by RPU power supply)
Operating Temperature 0 degC to 60 degC (outside of rack)
Storage Temperature -40 degC to +70 degC
Operating Humidity 5% to 95% non-condensing
Certifications UL Listed (Standard No. 508)
Country of Origin United States

Connections / Interfaces

  • 36-Point Connector: Front-facing connector providing terminal access to all 12 Form C relay contacts (Normally Open, Normally Closed, and Common for each channel).
  • Status Indicators: Seven-segment LED display indicating operating modes, normal operation states, and RPU error codes (codes 0-9). Individual LEDs indicate active Master CPU status for CPU1 and CPU2.
  • Jumper Blocks: Internal jumpers for selecting scan times, register transfer parameters, and backup bit mapping.

Installation Guidelines

The IC600RB752 circuit board is designed to install in the eighth slot from the left of the Redundant Processor Unit (RPU) rack. Use the extraction/insertion tool supplied with the RPU to seat the module firmly into place. Before mounting the faceplate, complete all necessary wiring to the 36-point connector. Secure the faceplate assembly to the rack using the top and bottom thumbscrews. Ensure the RPU RUN/HOLD switch on the main power supply is set to the HOLD position prior to installation or replacement to prevent equipment damage or unintended system shutdown.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the General Electric IC600RB752 module?
The General Electric IC600RB752 is a specialized Device Switch Module designed for Series Six Redundant Processor Unit PLC systems. It utilizes 12 independent Form C reed relays to allow external peripherals like printers and CRTs to be shared seamlessly between primary and backup CPUs. This module ensures secure isolation between the CPU and I/O switch modules within redundant architectures.
What relay specifications and contact ratings does the General Electric IC600RB752 feature?
The General Electric IC600RB752 features 12 Form C reed relays rated for a maximum current of 250 mA and a maximum voltage of 25V DC or AC. These relay contacts support resistive loads only and have a maximum switch bounce of 5 milliseconds. All 12 relay channels are accessible via a front-mounted 36-point connector for secure signal termination.
How does the General Electric IC600RB752 provide status monitoring and diagnostics?
The General Electric IC600RB752 is equipped with an integrated watchdog timer and a seven-segment LED status display for immediate visual feedback. The display indicates operating modes, normal operation states, and RPU error codes ranging from 0 to 9. Additionally, individual LEDs on the module clearly indicate the active Master CPU status for both CPU1 and CPU2.
What are the power requirements and physical installation guidelines for the General Electric IC600RB752?
The General Electric IC600RB752 requires a 5V DC power supply drawing 1.5 A, which is supplied directly by the RPU power supply. Technicians must install this circuit board in the eighth slot from the left of the RPU rack using the supplied extraction and insertion tool. Before installation, ensure the RPU power supply RUN/HOLD switch is set to the HOLD position to prevent equipment damage.
Reviews

IC600RB752

Stock & lead time on request

Call
1 of 1

General Electric IC600RB752 Series Six Device Switch Module

Only 17 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC600RB752

  • Country of origin:United States

  • Product Type: Device Switch Module

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The General Electric IC600RB752 is a specialized Device Switch Module designed for use within Series Six Redundant Processor Unit (RPU) PLC systems. This module features 12 Form C reed relays, enabling external peripherals such as printers, CRTs, and host computers to be shared seamlessly between primary and backup CPUs connected to the RPU. Accessible via a front-mounted 36-point connector, the module isolates the CPU and I/O switch modules, interfacing them securely to the Data Control Module and associated memory.

Equipped with an integrated watchdog timer and a seven-segment status display, the IC600RB752 provides immediate visual feedback for system configuration and error conditions. On-board option jumpers allow technicians to configure data transfer requirements and operational parameters to suit specific redundant automation architectures.

Features

  • 12 independent Form C reed relays for peripheral and communication line sharing
  • Front-mounted 36-point connector for secure external signal termination
  • Seven-segment LED status display for system configuration and error diagnostics
  • Watchdog timer monitoring with external error indication
  • Configurable on-board option jumpers for customized data transfer selection
  • UL listed under Standard No. 508 for industrial control equipment

Applications

  • Redundant Series Six PLC processor architectures
  • Sharing external peripherals (CRTs, printers, modems) between Master and Backup CPUs
  • Switching communication lines between redundant host computers or modems
  • Routing analog signals between redundant Master and Backup I/O chains

Technical Specifications

Parameter Specification
Manufacturer General Electric
Product Series Series Six (Redundant Processor Unit)
Catalog Number / SKU IC600RB752
Module Type Device Switch Module (Circuit Board)
Relay Type 12 Form C Reed Relays
Relay Contact Ratings 250 mA maximum current, 25V DC or AC maximum voltage, 5 ms max switch bounce (resistive loads only)
Power Requirements 5V DC, 1.5 A (supplied by RPU power supply)
Operating Temperature 0 degC to 60 degC (outside of rack)
Storage Temperature -40 degC to +70 degC
Operating Humidity 5% to 95% non-condensing
Certifications UL Listed (Standard No. 508)
Country of Origin United States

Connections / Interfaces

  • 36-Point Connector: Front-facing connector providing terminal access to all 12 Form C relay contacts (Normally Open, Normally Closed, and Common for each channel).
  • Status Indicators: Seven-segment LED display indicating operating modes, normal operation states, and RPU error codes (codes 0-9). Individual LEDs indicate active Master CPU status for CPU1 and CPU2.
  • Jumper Blocks: Internal jumpers for selecting scan times, register transfer parameters, and backup bit mapping.

Installation Guidelines

The IC600RB752 circuit board is designed to install in the eighth slot from the left of the Redundant Processor Unit (RPU) rack. Use the extraction/insertion tool supplied with the RPU to seat the module firmly into place. Before mounting the faceplate, complete all necessary wiring to the 36-point connector. Secure the faceplate assembly to the rack using the top and bottom thumbscrews. Ensure the RPU RUN/HOLD switch on the main power supply is set to the HOLD position prior to installation or replacement to prevent equipment damage or unintended system shutdown.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

General Electric IC600RB752 Series Six Device Switch Module

What is the primary function of the General Electric IC600RB752 module?

The General Electric IC600RB752 is a specialized Device Switch Module designed for Series Six Redundant Processor Unit PLC systems. It utilizes 12 independent Form C reed relays to allow external peripherals like printers and CRTs to be shared seamlessly between primary and backup CPUs. This module ensures secure isolation between the CPU and I/O switch modules within redundant architectures.

What relay specifications and contact ratings does the General Electric IC600RB752 feature?

The General Electric IC600RB752 features 12 Form C reed relays rated for a maximum current of 250 mA and a maximum voltage of 25V DC or AC. These relay contacts support resistive loads only and have a maximum switch bounce of 5 milliseconds. All 12 relay channels are accessible via a front-mounted 36-point connector for secure signal termination.

How does the General Electric IC600RB752 provide status monitoring and diagnostics?

The General Electric IC600RB752 is equipped with an integrated watchdog timer and a seven-segment LED status display for immediate visual feedback. The display indicates operating modes, normal operation states, and RPU error codes ranging from 0 to 9. Additionally, individual LEDs on the module clearly indicate the active Master CPU status for both CPU1 and CPU2.

What are the power requirements and physical installation guidelines for the General Electric IC600RB752?

The General Electric IC600RB752 requires a 5V DC power supply drawing 1.5 A, which is supplied directly by the RPU power supply. Technicians must install this circuit board in the eighth slot from the left of the RPU rack using the supplied extraction and insertion tool. Before installation, ensure the RPU power supply RUN/HOLD switch is set to the HOLD position to prevent equipment damage.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.