1 of 3

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

Only 10 item(s) left in stock
  • Manufacturer: HIMA

  • Product No.: F3331

  • Country of origin:Germany

  • Product Type: Safety Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 140g

  • Dimensions: 2cm x 19cm x 12.8cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The F 3331 (F3331) is a high-reliability, 8-fold safety-related output module engineered by HIMA for use in critical control systems requiring Requirement Class AK 1 through 6. This module is a cornerstone in Safety Instrumented Systems (SIS) within the chemical processing, subsea, and pharmaceutical industries, where safe isolation and integrated shutdown capabilities are paramount. The F 3331 supports resistive and inductive loads up to 500 mA (12 W) and is specifically designed to prevent unintended output signals in the event of an L- supply break. By providing continuous automated testing and line monitoring, it ensures that your safety loops remain functional, significantly reducing the Risk Priority Number (RPN) of your automated assets.

Technical Configuration

The F 3331 is designed with a "testable" architecture, meaning it performs self-diagnostics without interrupting the process logic. Its safety DNA is built around three core pillars:

  • Integrated Safety Shutdown: Hardware-level circuitry ensures the module can reach a de-energized state upon demand or internal fault detection.

  • Comprehensive Test Routines: The module executes a "walking-bit test" to check for cross-talking and switching capability, alongside a read-back feature that monitors output signals (0-signal threshold ≤ 6.5 V).

  • Line Monitoring: The module actively supervises the connection to the field device, detecting short circuits (tripping between 0.75 and 1.5 A) and line breaks (monitoring current between 0.5 and 9.5 mA).

Technical Specifications

Attribute Specification
Model F 3331
Brand HIMA
Output Channels 8 Channels, Testable
Safety Requirement Class AK 1 to 6
Load Capacity (Resistive/Inductive) Up to 500 mA (12 W)
Lamp Load Capacity Up to 4 W
Internal Voltage Drop Max. 2 V at 500 mA
Short Circuit Protection Integrated (0.75 to 1.5 A)
Test Signal Duration Max. 200 microseconds
Space Requirement 4 TE
Power Consumption (5V DC) 130 mA
Power Consumption (24V DC) 180 mA (plus load current)
Operating Temp 0 to 60 deg C

Technical FAQs

How does the module handle a "0 signal" fault?

The read-back operating point for a 0-signal is ≤ 6.5 V. It is important to note that if a fault causes the voltage to rise but stay below this 6.5 V threshold, the system will not detect it as a high-level fault.

What happens if there is a break in the L- supply?

The F 3331 is designed so that no output signal is possible if the L- supply is broken, ensuring a fail-safe condition.

Is there a limit to the length of the field wiring?

Yes, the admissible line resistance (combined in and out) is a maximum of 11 Ohm. Exceeding this resistance can interfere with the module's ability to accurately monitor line breaks and short circuits.


Engineering & Installation Guide

  • Load Balancing and Heat Management: While the module is rated for 500 mA per channel, the total power dissipation at 24 VDC can reach 180 mA plus the combined load. Ensure the cabinet has adequate convection cooling, as excessive ambient heat (above 60 deg C) can shift component tolerances and affect the undervoltage tripping point (standardly ≤ 16 V).

  • Inductive Load Protection: For inductive loads, although the module is rated for 12 W, we recommend installing external flyback diodes at the load side for high-cycle applications to further protect the integrated safety shutdown circuitry from back-EMF spikes.

  • Test Signal Transparency: The test signal duration is extremely short (max. 200 microseconds). While this is transparent to most industrial actuators and lamps, ensure that any downstream high-speed electronic interfaces are compatible with this transient diagnostic pulse to avoid "flicker" or false triggering.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

正在加载 PDF,请稍候…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...