HIMA

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

SKU F3331

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: HIMA

  • Product No.: F3331

  • Country of origin:Germany

  • Product Type: Safety Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 140g

  • Dimensions: 2cm x 19cm x 12.8cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The F 3331 (F3331) is a high-reliability, 8-fold safety-related output module engineered by HIMA for use in critical control systems requiring Requirement Class AK 1 through 6. This module is a cornerstone in Safety Instrumented Systems (SIS) within the chemical processing, subsea, and pharmaceutical industries, where safe isolation and integrated shutdown capabilities are paramount. The F 3331 supports resistive and inductive loads up to 500 mA (12 W) and is specifically designed to prevent unintended output signals in the event of an L- supply break. By providing continuous automated testing and line monitoring, it ensures that your safety loops remain functional, significantly reducing the Risk Priority Number (RPN) of your automated assets.

Technical Configuration

The F 3331 is designed with a "testable" architecture, meaning it performs self-diagnostics without interrupting the process logic. Its safety DNA is built around three core pillars:

  • Integrated Safety Shutdown: Hardware-level circuitry ensures the module can reach a de-energized state upon demand or internal fault detection.

  • Comprehensive Test Routines: The module executes a "walking-bit test" to check for cross-talking and switching capability, alongside a read-back feature that monitors output signals (0-signal threshold ≤ 6.5 V).

  • Line Monitoring: The module actively supervises the connection to the field device, detecting short circuits (tripping between 0.75 and 1.5 A) and line breaks (monitoring current between 0.5 and 9.5 mA).

Technical Specifications

Attribute Specification
Model F 3331
Brand HIMA
Output Channels 8 Channels, Testable
Safety Requirement Class AK 1 to 6
Load Capacity (Resistive/Inductive) Up to 500 mA (12 W)
Lamp Load Capacity Up to 4 W
Internal Voltage Drop Max. 2 V at 500 mA
Short Circuit Protection Integrated (0.75 to 1.5 A)
Test Signal Duration Max. 200 microseconds
Space Requirement 4 TE
Power Consumption (5V DC) 130 mA
Power Consumption (24V DC) 180 mA (plus load current)
Operating Temp 0 to 60 deg C

Technical FAQs

How does the module handle a "0 signal" fault?

The read-back operating point for a 0-signal is ≤ 6.5 V. It is important to note that if a fault causes the voltage to rise but stay below this 6.5 V threshold, the system will not detect it as a high-level fault.

What happens if there is a break in the L- supply?

The F 3331 is designed so that no output signal is possible if the L- supply is broken, ensuring a fail-safe condition.

Is there a limit to the length of the field wiring?

Yes, the admissible line resistance (combined in and out) is a maximum of 11 Ohm. Exceeding this resistance can interfere with the module's ability to accurately monitor line breaks and short circuits.


Engineering & Installation Guide

  • Load Balancing and Heat Management: While the module is rated for 500 mA per channel, the total power dissipation at 24 VDC can reach 180 mA plus the combined load. Ensure the cabinet has adequate convection cooling, as excessive ambient heat (above 60 deg C) can shift component tolerances and affect the undervoltage tripping point (standardly ≤ 16 V).

  • Inductive Load Protection: For inductive loads, although the module is rated for 12 W, we recommend installing external flyback diodes at the load side for high-cycle applications to further protect the integrated safety shutdown circuitry from back-EMF spikes.

  • Test Signal Transparency: The test signal duration is extremely short (max. 200 microseconds). While this is transparent to most industrial actuators and lamps, ensure that any downstream high-speed electronic interfaces are compatible with this transient diagnostic pulse to avoid "flicker" or false triggering.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

HIMA H41q/H51q F 3331 8-Channel Safety Output Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Germany
Power source
DC Power

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...