HIMA

HIMA H41q/H51q B9361 / B 9361 Assembly Kit

SKU B9361

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: HIMA
  • Product No.: B9361
  • Origin Germany
  • Product Type: Assembly Kit
  • Payment: T/T, Western Union
  • Weight: 8.5 kg
  • Dimensions: 222 mm x 248 mm x 483 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

The HIMA B 9361 is an assembly kit providing an additional 5 V power supply (loadable up to 18 A) for HIMA H51q safety systems. The B 9361 is utilized when the built-in power supply modules within the central rack are insufficient to supply the 5 V circuits (for example, when current requirement I > 18 A for three power supply modules F 7126 in a redundant control setup). Built around a 19-inch K 1408 central rack (5 units high) with an integrated cable tray, the B 9361 includes an F 7126 power supply module (24 V / 5 V, 10 A), an F 7131 power supply monitoring module, and rear-mounted decoupling, fusing, and fan monitoring units (Z 6011, Z 6012, and Z 6013). High availability is ensured as two out of three power supply modules can maintain the 5 V supply.

Features

  • Built around a 19-inch K 1408 central rack (5 units high, 5U) with integrated cable tray
  • Provides an additional 5 V power supply loadable up to 18 A for H51q systems
  • Equipped with 1 x F 7126 power supply module (24 V / 5 V DC, 10 A) in base kit
  • Option to expand with up to 2 x additional F 7126 power supply modules (PS2, PS3) operating with 5 V outputs in parallel
  • Equipped with 1 x F 7131 power supply monitoring module
  • Includes 14 socket connectors for installing standard F-type modules of the HIMA Planar System
  • Rear-mounted Z 6011 modules for decoupling and fusing to feed power supply modules
  • Rear-mounted Z 6012 fan module featuring fan run monitoring and fuse monitoring
  • Rear-mounted Z 6013 modules for decoupling and fusing of supply voltage for Z 6012
  • Redundant supply availability where 2 out of 3 power supply modules guarantee the 5 V supply

Applications

  • Additional 5 V DC power expansion for HIMA H51q safety control systems
  • Integration and housing of HIMA Planar System F-type modules
  • Power distribution and monitoring in industrial safety instrumentation installations

Ordering Information

Component Description Part / Module Designation
Central Rack 19-inch rack, 5 units high, with integrated cable tray 1 x K 1408
Rear Module Decoupling and fusing to feed power supply modules 3 x Z 6011
Rear Module Fan with fan run monitoring and fuse monitoring 1 x Z 6012
Rear Module Decoupling and fusing of supply voltage for Z 6012 2 x Z 6013
Included Module Power supply module 24 V / 5 V, 10 A (PS1) 1 x F 7126
Included Module Power supply monitoring module 1 x F 7131
Included Connectors Socket connectors for standard (F type) modules of HIMA Planar System 14 x Socket connectors
Optional Module Power supply module 24 V / 5 V (PS2, PS3) 2 x F 7126 (Separate order)
Optional Modules Standard (F type) modules of the HIMA Planar System 1...14 x F type modules (Separate order)

Technical Specifications

Parameter Specification
Manufacturer HIMA
Model B 9361
System Compatibility HIMA H51q Systems, HIMA Planar System
Rack Dimensions / Form Factor K 1408 central rack, 19 inches, 5 units high (5U)
Additional 5 V Capacity Loadable up to 18 A
Base Power Supply Module 1 x F 7126 (24 V / 5 V DC, 10 A)
Power Supply Redundancy 2 of 3 F 7126 modules guarantee 5 V supply
Internal Fuse Z 6011 4 A slow blow (5 x 20 mm, HIMA part no. 57 0174409)
Internal Fuse Z 6013 1.6 A slow blow (5 x 20 mm, HIMA part no. 57 0174169)

Connections/Interfaces

Connection Point Wire and Connection Details Fusing Function / Use
XG.21/22/23:2 (L+) RD 2.5 mm2, Faston 6.3 x 0.8 max. 16 A gL 24 VDC Supply for PS1...PS3
XG.21/22/23:1 (L-) BK 2.5 mm2, Faston 6.3 x 0.8 - Reference pole for 24 VDC Supply
XG.2: +5 V YE 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances > 2 m) - Output +5 VDC (Supply I/O subrack B 9302)
XG.3: GND GN 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances > 2 m) - Output GND (Supply I/O subrack B 9302, to be connected with GND of central rack)
XG.24:2 (L+) RD 1.5 mm2, Faston 6.3 x 0.8 - Output 24 VDC (Supply fuse monitoring and IO-CON in I/O subrack)
XG.25:2 (L+) RD 1.5 mm2, Faston 6.3 x 0.8 - Output 24 VDC (Supply fuse monitoring and IO-CON in I/O subrack for 2nd I/O bus B 5222-2, B 5223-2, B 5232-2, and B 5233-2 only)
XG.26:4/5/6 GY 0.5 mm2, Faston 2.8 x 0.8 max. 4 A slow blow Floating NO/NC contact for signalling (fuse and fan monitoring)
XG .4 - - Wiring ex works: Feeding L+ (24 V) for power supply module F 7126
XG .5 - - Wiring ex works: Feeding L- (24 V) for power supply module F 7126
XG .26: 2, 3 - - Wiring ex works: Power supply for fans
XG .26: 1 - - Wiring ex works: Wire for fuse monitoring
XG .1:9-11 - - Wiring by customer: Connections for monitoring of power supplies by F 7131
XG .21, XG .22, XG .23 - - Wiring by customer: Connections for Z 6011 (decoupling and fusing to feed power supply modules)
XG .24, XG .25 - - Wiring by customer: Connections for Z 6013 (decoupling and fusing of supply voltage for Z 6012 and feeding of coupling module F 7553 in I/O subrack)

Installation Guidelines

  • Earthing: Installation of the assembly kit requires a conductive connection to the frame or a separate earth connection installed according to EMC requirements. Connection PE earth uses Faston 6.3 x 0.8 mm. Pay strict attention to manufacturer recommendations when detaching and replugging Faston connectors.
  • 5 V Circuit Connection: The 5 V circuits of power supply modules in the central rack and in the additional power supply should not be switched in parallel; however, the GND of both power supplies must be connected together.
  • 5 V Output Wiring: For distances greater than 2 m between the 5 VDC output (XG.2 / XG.3) and the I/O subrack (B 9302), use a wire cross section of 6 mm2 instead of 2.5 mm2.

Compliance and Certifications

  • CE
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the HIMA B 9361 used for?
The HIMA B 9361 is an assembly kit used to provide an additional 5 V DC power supply loadable up to 18 A for HIMA H51q safety systems when central rack power is insufficient.
Which system does the module belong to?
The assembly kit belongs to HIMA H51q safety systems and accommodates standard F-type modules of the HIMA Planar System.
What modules are included in the standard B 9361 kit?
The kit includes a K 1408 central rack (5U, 19-inch), 1 x F 7126 power supply module (24 V / 5 V, 10 A), 1 x F 7131 power supply monitoring module, 14 slot connectors for F-type modules, and rear-mounted Z 6011, Z 6012, and Z 6013 modules.
How is power redundancy maintained in the B 9361?
Power availability is maintained because 2 out of 3 F 7126 power supply modules are capable of guaranteeing the 5 V supply.
How should the 5 V circuits be grounded and wired?
The 5 V circuits of the central rack and additional power supply must not be switched in parallel, but the GND of both power supplies must be connected together.
Reviews

B9361

Stock & lead time on request

Call
1 of 1

HIMA H41q/H51q B9361 / B 9361 Assembly Kit

Only 5 item(s) left in stock
  • Manufacturer: HIMA

  • Product No.: B9361

  • Country of origin:Germany

  • Product Type: Assembly Kit

  • Payment: T/T, Western Union

  • Weight: 8500g

  • Dimensions: 222 mm x 248 mm x 483 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The HIMA B 9361 is an assembly kit providing an additional 5 V power supply (loadable up to 18 A) for HIMA H51q safety systems. The B 9361 is utilized when the built-in power supply modules within the central rack are insufficient to supply the 5 V circuits (for example, when current requirement I > 18 A for three power supply modules F 7126 in a redundant control setup). Built around a 19-inch K 1408 central rack (5 units high) with an integrated cable tray, the B 9361 includes an F 7126 power supply module (24 V / 5 V, 10 A), an F 7131 power supply monitoring module, and rear-mounted decoupling, fusing, and fan monitoring units (Z 6011, Z 6012, and Z 6013). High availability is ensured as two out of three power supply modules can maintain the 5 V supply.

Features

  • Built around a 19-inch K 1408 central rack (5 units high, 5U) with integrated cable tray
  • Provides an additional 5 V power supply loadable up to 18 A for H51q systems
  • Equipped with 1 x F 7126 power supply module (24 V / 5 V DC, 10 A) in base kit
  • Option to expand with up to 2 x additional F 7126 power supply modules (PS2, PS3) operating with 5 V outputs in parallel
  • Equipped with 1 x F 7131 power supply monitoring module
  • Includes 14 socket connectors for installing standard F-type modules of the HIMA Planar System
  • Rear-mounted Z 6011 modules for decoupling and fusing to feed power supply modules
  • Rear-mounted Z 6012 fan module featuring fan run monitoring and fuse monitoring
  • Rear-mounted Z 6013 modules for decoupling and fusing of supply voltage for Z 6012
  • Redundant supply availability where 2 out of 3 power supply modules guarantee the 5 V supply

Applications

  • Additional 5 V DC power expansion for HIMA H51q safety control systems
  • Integration and housing of HIMA Planar System F-type modules
  • Power distribution and monitoring in industrial safety instrumentation installations

Ordering Information

Component Description Part / Module Designation
Central Rack 19-inch rack, 5 units high, with integrated cable tray 1 x K 1408
Rear Module Decoupling and fusing to feed power supply modules 3 x Z 6011
Rear Module Fan with fan run monitoring and fuse monitoring 1 x Z 6012
Rear Module Decoupling and fusing of supply voltage for Z 6012 2 x Z 6013
Included Module Power supply module 24 V / 5 V, 10 A (PS1) 1 x F 7126
Included Module Power supply monitoring module 1 x F 7131
Included Connectors Socket connectors for standard (F type) modules of HIMA Planar System 14 x Socket connectors
Optional Module Power supply module 24 V / 5 V (PS2, PS3) 2 x F 7126 (Separate order)
Optional Modules Standard (F type) modules of the HIMA Planar System 1...14 x F type modules (Separate order)

Technical Specifications

Parameter Specification
Manufacturer HIMA
Model B 9361
System Compatibility HIMA H51q Systems, HIMA Planar System
Rack Dimensions / Form Factor K 1408 central rack, 19 inches, 5 units high (5U)
Additional 5 V Capacity Loadable up to 18 A
Base Power Supply Module 1 x F 7126 (24 V / 5 V DC, 10 A)
Power Supply Redundancy 2 of 3 F 7126 modules guarantee 5 V supply
Internal Fuse Z 6011 4 A slow blow (5 x 20 mm, HIMA part no. 57 0174409)
Internal Fuse Z 6013 1.6 A slow blow (5 x 20 mm, HIMA part no. 57 0174169)

Connections/Interfaces

Connection Point Wire and Connection Details Fusing Function / Use
XG.21/22/23:2 (L+) RD 2.5 mm2, Faston 6.3 x 0.8 max. 16 A gL 24 VDC Supply for PS1...PS3
XG.21/22/23:1 (L-) BK 2.5 mm2, Faston 6.3 x 0.8 - Reference pole for 24 VDC Supply
XG.2: +5 V YE 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances > 2 m) - Output +5 VDC (Supply I/O subrack B 9302)
XG.3: GND GN 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances > 2 m) - Output GND (Supply I/O subrack B 9302, to be connected with GND of central rack)
XG.24:2 (L+) RD 1.5 mm2, Faston 6.3 x 0.8 - Output 24 VDC (Supply fuse monitoring and IO-CON in I/O subrack)
XG.25:2 (L+) RD 1.5 mm2, Faston 6.3 x 0.8 - Output 24 VDC (Supply fuse monitoring and IO-CON in I/O subrack for 2nd I/O bus B 5222-2, B 5223-2, B 5232-2, and B 5233-2 only)
XG.26:4/5/6 GY 0.5 mm2, Faston 2.8 x 0.8 max. 4 A slow blow Floating NO/NC contact for signalling (fuse and fan monitoring)
XG .4 - - Wiring ex works: Feeding L+ (24 V) for power supply module F 7126
XG .5 - - Wiring ex works: Feeding L- (24 V) for power supply module F 7126
XG .26: 2, 3 - - Wiring ex works: Power supply for fans
XG .26: 1 - - Wiring ex works: Wire for fuse monitoring
XG .1:9-11 - - Wiring by customer: Connections for monitoring of power supplies by F 7131
XG .21, XG .22, XG .23 - - Wiring by customer: Connections for Z 6011 (decoupling and fusing to feed power supply modules)
XG .24, XG .25 - - Wiring by customer: Connections for Z 6013 (decoupling and fusing of supply voltage for Z 6012 and feeding of coupling module F 7553 in I/O subrack)

Installation Guidelines

  • Earthing: Installation of the assembly kit requires a conductive connection to the frame or a separate earth connection installed according to EMC requirements. Connection PE earth uses Faston 6.3 x 0.8 mm. Pay strict attention to manufacturer recommendations when detaching and replugging Faston connectors.
  • 5 V Circuit Connection: The 5 V circuits of power supply modules in the central rack and in the additional power supply should not be switched in parallel; however, the GND of both power supplies must be connected together.
  • 5 V Output Wiring: For distances greater than 2 m between the 5 VDC output (XG.2 / XG.3) and the I/O subrack (B 9302), use a wire cross section of 6 mm2 instead of 2.5 mm2.

Compliance and Certifications

  • CE

What is the HIMA B 9361 used for?

The HIMA B 9361 is an assembly kit used to provide an additional 5 V DC power supply loadable up to 18 A for HIMA H51q safety systems when central rack power is insufficient.

Which system does the module belong to?

The assembly kit belongs to HIMA H51q safety systems and accommodates standard F-type modules of the HIMA Planar System.

What modules are included in the standard B 9361 kit?

The kit includes a K 1408 central rack (5U, 19-inch), 1 x F 7126 power supply module (24 V / 5 V, 10 A), 1 x F 7131 power supply monitoring module, 14 slot connectors for F-type modules, and rear-mounted Z 6011, Z 6012, and Z 6013 modules.

How is power redundancy maintained in the B 9361?

Power availability is maintained because 2 out of 3 F 7126 power supply modules are capable of guaranteeing the 5 V supply.

How should the 5 V circuits be grounded and wired?

The 5 V circuits of the central rack and additional power supply must not be switched in parallel, but the GND of both power supplies must be connected together.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...