HIMA

HIMA H41q/H51q B9361 / B 9361 Assembly Kit

SKU B9361

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: HIMA

  • Product No.: B9361

  • Country of origin:Germany

  • Product Type: Assembly Kit

  • Payment: T/T, Western Union

  • Weight: 8500g

  • Dimensions: 222 mm x 248 mm x 483 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

The HIMA B 9361 is an assembly kit providing an additional 5 V power supply (loadable up to 18 A) for HIMA H51q safety systems. The B 9361 is utilized when the built-in power supply modules within the central rack are insufficient to supply the 5 V circuits (for example, when current requirement I > 18 A for three power supply modules F 7126 in a redundant control setup). Built around a 19-inch K 1408 central rack (5 units high) with an integrated cable tray, the B 9361 includes an F 7126 power supply module (24 V / 5 V, 10 A), an F 7131 power supply monitoring module, and rear-mounted decoupling, fusing, and fan monitoring units (Z 6011, Z 6012, and Z 6013). High availability is ensured as two out of three power supply modules can maintain the 5 V supply.

Features

  • Built around a 19-inch K 1408 central rack (5 units high, 5U) with integrated cable tray
  • Provides an additional 5 V power supply loadable up to 18 A for H51q systems
  • Equipped with 1 x F 7126 power supply module (24 V / 5 V DC, 10 A) in base kit
  • Option to expand with up to 2 x additional F 7126 power supply modules (PS2, PS3) operating with 5 V outputs in parallel
  • Equipped with 1 x F 7131 power supply monitoring module
  • Includes 14 socket connectors for installing standard F-type modules of the HIMA Planar System
  • Rear-mounted Z 6011 modules for decoupling and fusing to feed power supply modules
  • Rear-mounted Z 6012 fan module featuring fan run monitoring and fuse monitoring
  • Rear-mounted Z 6013 modules for decoupling and fusing of supply voltage for Z 6012
  • Redundant supply availability where 2 out of 3 power supply modules guarantee the 5 V supply

Applications

  • Additional 5 V DC power expansion for HIMA H51q safety control systems
  • Integration and housing of HIMA Planar System F-type modules
  • Power distribution and monitoring in industrial safety instrumentation installations

Ordering Information

Component Description Part / Module Designation
Central Rack 19-inch rack, 5 units high, with integrated cable tray 1 x K 1408
Rear Module Decoupling and fusing to feed power supply modules 3 x Z 6011
Rear Module Fan with fan run monitoring and fuse monitoring 1 x Z 6012
Rear Module Decoupling and fusing of supply voltage for Z 6012 2 x Z 6013
Included Module Power supply module 24 V / 5 V, 10 A (PS1) 1 x F 7126
Included Module Power supply monitoring module 1 x F 7131
Included Connectors Socket connectors for standard (F type) modules of HIMA Planar System 14 x Socket connectors
Optional Module Power supply module 24 V / 5 V (PS2, PS3) 2 x F 7126 (Separate order)
Optional Modules Standard (F type) modules of the HIMA Planar System 1...14 x F type modules (Separate order)

Technical Specifications

Parameter Specification
Manufacturer HIMA
Model B 9361
System Compatibility HIMA H51q Systems, HIMA Planar System
Rack Dimensions / Form Factor K 1408 central rack, 19 inches, 5 units high (5U)
Additional 5 V Capacity Loadable up to 18 A
Base Power Supply Module 1 x F 7126 (24 V / 5 V DC, 10 A)
Power Supply Redundancy 2 of 3 F 7126 modules guarantee 5 V supply
Internal Fuse Z 6011 4 A slow blow (5 x 20 mm, HIMA part no. 57 0174409)
Internal Fuse Z 6013 1.6 A slow blow (5 x 20 mm, HIMA part no. 57 0174169)

Connections/Interfaces

Connection Point Wire and Connection Details Fusing Function / Use
XG.21/22/23:2 (L+) RD 2.5 mm2, Faston 6.3 x 0.8 max. 16 A gL 24 VDC Supply for PS1...PS3
XG.21/22/23:1 (L-) BK 2.5 mm2, Faston 6.3 x 0.8 - Reference pole for 24 VDC Supply
XG.2: +5 V YE 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances > 2 m) - Output +5 VDC (Supply I/O subrack B 9302)
XG.3: GND GN 2 x 2.5 mm2, Faston 6.3 x 0.8 (cross section 6 mm2 for distances > 2 m) - Output GND (Supply I/O subrack B 9302, to be connected with GND of central rack)
XG.24:2 (L+) RD 1.5 mm2, Faston 6.3 x 0.8 - Output 24 VDC (Supply fuse monitoring and IO-CON in I/O subrack)
XG.25:2 (L+) RD 1.5 mm2, Faston 6.3 x 0.8 - Output 24 VDC (Supply fuse monitoring and IO-CON in I/O subrack for 2nd I/O bus B 5222-2, B 5223-2, B 5232-2, and B 5233-2 only)
XG.26:4/5/6 GY 0.5 mm2, Faston 2.8 x 0.8 max. 4 A slow blow Floating NO/NC contact for signalling (fuse and fan monitoring)
XG .4 - - Wiring ex works: Feeding L+ (24 V) for power supply module F 7126
XG .5 - - Wiring ex works: Feeding L- (24 V) for power supply module F 7126
XG .26: 2, 3 - - Wiring ex works: Power supply for fans
XG .26: 1 - - Wiring ex works: Wire for fuse monitoring
XG .1:9-11 - - Wiring by customer: Connections for monitoring of power supplies by F 7131
XG .21, XG .22, XG .23 - - Wiring by customer: Connections for Z 6011 (decoupling and fusing to feed power supply modules)
XG .24, XG .25 - - Wiring by customer: Connections for Z 6013 (decoupling and fusing of supply voltage for Z 6012 and feeding of coupling module F 7553 in I/O subrack)

Installation Guidelines

  • Earthing: Installation of the assembly kit requires a conductive connection to the frame or a separate earth connection installed according to EMC requirements. Connection PE earth uses Faston 6.3 x 0.8 mm. Pay strict attention to manufacturer recommendations when detaching and replugging Faston connectors.
  • 5 V Circuit Connection: The 5 V circuits of power supply modules in the central rack and in the additional power supply should not be switched in parallel; however, the GND of both power supplies must be connected together.
  • 5 V Output Wiring: For distances greater than 2 m between the 5 VDC output (XG.2 / XG.3) and the I/O subrack (B 9302), use a wire cross section of 6 mm2 instead of 2.5 mm2.

Compliance and Certifications

  • CE

FAQ

What is the HIMA B 9361 used for?

The HIMA B 9361 is an assembly kit used to provide an additional 5 V DC power supply loadable up to 18 A for HIMA H51q safety systems when central rack power is insufficient.

Which system does the module belong to?

The assembly kit belongs to HIMA H51q safety systems and accommodates standard F-type modules of the HIMA Planar System.

What modules are included in the standard B 9361 kit?

The kit includes a K 1408 central rack (5U, 19-inch), 1 x F 7126 power supply module (24 V / 5 V, 10 A), 1 x F 7131 power supply monitoring module, 14 slot connectors for F-type modules, and rear-mounted Z 6011, Z 6012, and Z 6013 modules.

How is power redundancy maintained in the B 9361?

Power availability is maintained because 2 out of 3 F 7126 power supply modules are capable of guaranteeing the 5 V supply.

How should the 5 V circuits be grounded and wired?

The 5 V circuits of the central rack and additional power supply must not be switched in parallel, but the GND of both power supplies must be connected together.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.