Honeywell

Honeywell 51195096-200 Input/Output Module

SKU 51195096-200

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 51195096-200
  • Origin United States
  • Product Type: Input/Output Boards
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.2 kg
  • Dimensions: 2cm x 13.7cm x 13.7cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The Honeywell 51195096-200 is a specialized industrial input/output board designed for deployment within established control architectures, including legacy TDC 3000 and Experion PKS automation environments. This hardware module functions as a critical interface layer for signal processing and communication routing within industrial process control systems, bridging field-level signals with core processing nodes.

Engineered for high-reliability industrial operations, the module ensures deterministic data exchange and robust signal conditioning. It integrates seamlessly into standard system cabinets, supporting continuous plant operations and high-availability process control strategies across continuous manufacturing and heavy industrial sectors.

Features

  • Engineered specifically for Honeywell TDC 3000 and Experion PKS system architectures
  • Supports reliable signal processing and input/output routing
  • Designed for standard industrial rack mounting within system enclosures
  • Built to meet stringent industrial environmental operating standards

Applications

  • Distributed Control Systems (DCS)
  • Continuous process manufacturing
  • Oil and gas production facilities
  • Chemical processing plants
  • Power generation and distribution

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model / Part Number 51195096-200
Product Type Input/Output Board
System Compatibility TDC 3000, Experion PKS
Mounting Type Rack Mount / System Chassis
Country of Origin United States

Installation Guidelines

  1. Verify the part number and ensure the module matches the required system slot specification.
  2. De-energize the target chassis or cabinet before performing any hardware installation.
  3. Inspect the module and edge connectors for any transit damage or contamination.
  4. Carefully align the board with the designated backplane slot and insert evenly until fully seated.
  5. Secure any retention fasteners to maintain mechanical stability and proper grounding.
  6. Restore system power and verify module status via the control system engineering station.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What systems are compatible with the Honeywell 51195096-200?
The Honeywell 51195096-200 is designed for integration within Honeywell TDC 3000 and Experion PKS distributed control system architectures.
What is the primary function of the Honeywell 51195096-200?
The Honeywell 51195096-200 functions as an industrial input/output board that manages signal processing and communication routing between field devices and the core control system.
How should the Honeywell 51195096-200 be installed?
The Honeywell 51195096-200 must be installed in a de-energized system chassis, carefully aligned with the designated backplane slot, securely seated, and verified through the engineering station after power restoration.
Reviews

51195096-200

Stock & lead time on request

Call
1 of 3

Honeywell 51195096-200 Input/Output Module

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51195096-200

  • Country of origin:United States

  • Product Type: Input/Output Boards

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 2cm x 13.7cm x 13.7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Honeywell 51195096-200 is a specialized industrial input/output board designed for deployment within established control architectures, including legacy TDC 3000 and Experion PKS automation environments. This hardware module functions as a critical interface layer for signal processing and communication routing within industrial process control systems, bridging field-level signals with core processing nodes.

Engineered for high-reliability industrial operations, the module ensures deterministic data exchange and robust signal conditioning. It integrates seamlessly into standard system cabinets, supporting continuous plant operations and high-availability process control strategies across continuous manufacturing and heavy industrial sectors.

Features

  • Engineered specifically for Honeywell TDC 3000 and Experion PKS system architectures
  • Supports reliable signal processing and input/output routing
  • Designed for standard industrial rack mounting within system enclosures
  • Built to meet stringent industrial environmental operating standards

Applications

  • Distributed Control Systems (DCS)
  • Continuous process manufacturing
  • Oil and gas production facilities
  • Chemical processing plants
  • Power generation and distribution

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model / Part Number 51195096-200
Product Type Input/Output Board
System Compatibility TDC 3000, Experion PKS
Mounting Type Rack Mount / System Chassis
Country of Origin United States

Installation Guidelines

  1. Verify the part number and ensure the module matches the required system slot specification.
  2. De-energize the target chassis or cabinet before performing any hardware installation.
  3. Inspect the module and edge connectors for any transit damage or contamination.
  4. Carefully align the board with the designated backplane slot and insert evenly until fully seated.
  5. Secure any retention fasteners to maintain mechanical stability and proper grounding.
  6. Restore system power and verify module status via the control system engineering station.
Loading product navigation…

What systems are compatible with the Honeywell 51195096-200?

The Honeywell 51195096-200 is designed for integration within Honeywell TDC 3000 and Experion PKS distributed control system architectures.

What is the primary function of the Honeywell 51195096-200?

The Honeywell 51195096-200 functions as an industrial input/output board that manages signal processing and communication routing between field devices and the core control system.

How should the Honeywell 51195096-200 be installed?

The Honeywell 51195096-200 must be installed in a de-energized system chassis, carefully aligned with the designated backplane slot, securely seated, and verified through the engineering station after power restoration.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.