Honeywell

Honeywell 51452822-502 Power/Output Printed Wiring Assembly

SKU 51452822-502

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 51452822-502

  • Country of origin:United States

  • Product Type: Power Output Modules

  • Payment: T/T, Western Union

  • Weight: 900g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for integration into compatible industrial process controllers, the Honeywell 51452822-502 serves as a robust Power/Output Printed Wiring Assembly (PWA). This hardware component incorporates power regulation circuitry alongside two electromechanical (E-M) relays, enabling reliable load switching and power management within demanding process control environments.

Operating over a wide input voltage range of 90 to 264 Vac, this assembly ensures consistent power distribution and discrete output control. The onboard electromechanical relays allow for a direct interface with external process equipment, indicating lamps, alarms, or low-power actuators without requiring external isolation barriers in standard configurations.

Features

  • Dual integrated electromechanical relay outputs for reliable physical switching operations.
  • Wide universal AC input voltage range supporting global utility standards (90 to 264 Vac).
  • Robust Printed Wiring Assembly (PWA) design engineered for long-term industrial duty cycles.
  • Direct replacement board architecture for compatible Honeywell industrial instrumentation.

Applications

  • Industrial process control systems and loop controllers.
  • Direct control of low-power solenoids, contactors, and actuators.
  • Alarm and status indication systems in control panels.
  • Power distribution and interface management inside instrumentation enclosures.

Technical Specifications

Manufacturer Honeywell
Part Number/Model 51452822-502
Product Type Power/Output Printed Wiring Assembly (PWA)
Relay Outputs 2 Electromechanical (E-M) Relays
Operating Voltage 90 to 264 Vac
Weight 0.9 kg

Installation Guidelines

To ensure safe and reliable operation of the Honeywell 51452822-502, observe the following engineering instructions:

  • Electrostatic Discharge (ESD) Protection: This module contains sensitive electronic components. Always wear an approved ESD wrist strap grounded to the chassis when handling or installing the card.
  • Power Isolation: Ensure all incoming AC power lines (90-264 Vac) are completely de-energized and locked out before attempting to install or remove the assembly.
  • Mounting: Secure the printed wiring assembly firmly into its designated slots within the controller housing to maintain proper mechanical alignment and electrical contact.
  • Conductor Routing: Route high-voltage AC input lines and relay load wiring away from low-voltage signal lines to minimize electromagnetic interference.

FAQ

What is the primary function of the Honeywell 51452822-502?

The Honeywell 51452822-502 is a Power/Output Printed Wiring Assembly (PWA) that provides regulated system power and features two onboard electromechanical relays for discrete device control.

What voltage range does this board support?

This module operates over a wide universal AC input voltage range of 90 to 264 Vac.

How many relays are included on the 51452822-502?

The board features 2 electromechanical (E-M) relays designed for process switching applications.

What precautions should be taken during installation?

Always turn off and lock out the AC power line before handling, and use proper ESD protection (such as a grounded wrist strap) to avoid damaging the components.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.