The Honeywell 900G01-0202 is a high-density Digital Input Module designed for precision signal monitoring within industrial control systems. This module features 16 single-ended input channels, providing reliable sensing and interface capability for field devices. It is engineered with integral galvanic isolation to protect the internal controller and backplane circuitry from field-side electrical transients, ensuring robust operation in demanding automation environments.

Features

  • Channel Density: 16 single-ended input channels per module
  • Galvanic Isolation: Enhanced protection between field wiring and internal microcontroller/backplane
  • Fast Response Times: Optimized for rapid signal status changes (4 ms OFF-to-ON, 6 ms ON-to-OFF)
  • Low Power Consumption: Efficient power supply loading on both 5V and 24V rails

Applications

  • Status monitoring of limit switches, pushbuttons, and proximity sensors
  • Discrete signal acquisition in PLC or DCS architectures
  • Safety and process interlock monitoring
  • Industrial machinery control and diagnostic feedback

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 900G01-0202
Product Type Digital Input Module
Inputs per module 16 (single-ended)
Voltage Supplied 15 Vdc nominal
Max. Contact Resistance 1000 ohms
OFF to ON Response 4 ms max
ON to OFF Response 6 ms max
Switching Current 2.6 mA nominal
Power Loading 5V @ 130 mA max; 24V @ 40 mA max
Dimensions 137mm H x 35.6mm W (5.4in H x 1.4in W)
Net Weight 0.354 kg
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Install the module into the designated slot on the system backplane, ensuring proper alignment to prevent pin damage.
  • Grounding: Maintain consistent system-wide grounding to ensure the effectiveness of the galvanic isolation.
  • Wiring: Keep input field wiring away from high-voltage AC lines to prevent crosstalk and noise injection.
  • Polarity: Ensure correct polarity during field device connection, as the module requires a 15 Vdc nominal supply.
  • Environment: Ensure the module operates within the manufacturer-specified thermal range to guarantee the rated response times.

FAQ

What is the channel capacity of the 900G01-0202?

This module features 16 single-ended digital input channels.

What is the purpose of the galvanic isolation in this module?

The galvanic isolation provides a protective barrier between the field wiring and the internal microcontroller or backplane, preventing electrical transients from damaging the system.

What are the response times for this digital input module?

The module has an OFF-to-ON response time of 4 ms maximum and an ON-to-OFF response time of 6 ms maximum.

What power supply loading should be accounted for?

The module requires a maximum of 130 mA at 5V and 40 mA at 24V.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.