Honeywell

Honeywell CC-PDIL01 51405040-176 Experion PKS Series C Digital Input Module

SKU CC-PDIL01 51405040-176

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: CC-PDIL01 51405040-176

  • Country of origin:United States

  • Product Type: Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 360g

  • Dimensions: 14.5 x 5.5 x 16.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell CC-PDIL01 (Model 51405040-176) is a high-density Digital Input Module designed for the Experion Process Knowledge System (PKS) platform. Operating as an integral component of the Series C distributed control architecture, this module interfaces industrial discrete sensor signals—such as proximity switches, pushbuttons, and auxiliary contacts—with the C300 controller or remote node architecture.

Engineered for continuous process control environments, the CC-PDIL01 executes high-integrity signal acquisition while providing channel-level galvanic isolation. Its modular design allows direct mounting onto Series C I/O carriers, supporting redundant node configurations and online module replacement (IOMR) to maintain continuous process operation during maintenance procedures.

Features

  • Channel Capacity: 32 discrete digital input channels per module.
  • Input Voltage Rating: 24 VDC sink/source compatible.
  • Fault Diagnostics: Individual channel status LEDs and loop-powered field device monitoring.
  • Isolation: Optical channel-to-bus and channel-to-channel isolation.
  • Hot-Swappable: Supports insertion and removal under power (RIUP) on Series C I/O carriers.

Applications

  • Emergency shutdown (ESD) system status monitoring
  • Discrete valve position and limit switch feedback acquisition
  • Motor run/stop status and auxiliary contact tracking
  • Process interlock and safety trip monitoring within Experion PKS architectures

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Product Family Experion PKS Series C
Catalog Number / Model CC-PDIL01 (51405040-176)
Module Type Digital Input Module
Number of Channels 32 channels
Input Voltage Range 19.2 to 30 VDC
Current Drain (5 VDC) 150 mA typical
Current Drain (24 VDC Bus) 100 mA typical (excluding field loop power)
Mounting Type Series C I/O Terminal Block and Carrier
Operating Temperature 0 to 60 Celsius
Storage Temperature -40 to 85 Celsius
Relative Humidity 10% to 90% non-condensing
Country of Origin United States

Connections / Interfaces

The CC-PDIL01 interfaces with field wiring via the Series C I/O Terminal Block (TB), which mounts directly onto the I/O module. System communication and power distribution are routed through the backplane of the Series C I/O carrier, connecting the module to the I/O Processor (IOP) and redundant Control Firewall network.

Compliance and Certifications

    CE compliant for EMC directive and low voltage directive

    CSA hazardous locations certification (Class I, Division 2, Groups A, B, C, D)

    ATEX zone 2 rating when installed in accordance with system installation instructions

FAQ

What control system platform is the Honeywell CC-PDIL01 designed for?

The CC-PDIL01 is designed specifically for the Honeywell Experion PKS system, utilizing the Series C I/O architecture.

How many channels does the CC-PDIL01 module support?

The module provides 32 discrete digital input channels operating at 24 VDC.

Does the CC-PDIL01 support hot-swapping?

Yes, the module supports Removal and Insertion Under Power (RIUP) when mounted on a standard Series C I/O carrier.

What is the catalog ordering number for this module?

The primary model number is CC-PDIL01, corresponding to manufacturing part number 51405040-176.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...