Description
Designed to safeguard critical control configurations and real-time database integrity, the Honeywell CC-SCMB03 serves as the dedicated C300 Memory Backup Assembly within the Experion Process Knowledge System (PKS). This hardware component provides localized energy storage to maintain volatile RAM states during unexpected primary power disruptions, preventing unexpected cold starts and associated process delays.
The CC-SCMB03 mounts directly to the designated termination structures of the Experion C300 controller system. By securing internal controller database states, this assembly ensures that setpoints, PID loops, and control strategies are rapidly recovered once main power is restored. Engineered for heavy industrial deployments, it integrates seamlessly with standard Honeywell I/O systems to maintain reliable plant uptime.
Features
- Ensures non-volatile retention of controller configuration data and runtime parameters.
- Minimizes downtime by eliminating manual database reload processes after power failures.
- Designed for direct integration with Experion C300 Input Output Termination Assemblies (IOTA).
- Continuous self-diagnostics report backup status and battery health metrics directly to the control network.
- Industrial-grade hardware engineered to withstand typical control room temperature and humidity fluctuations.
Applications
- Oil and gas refining and petrochemical processing control.
- Continuous process automation in chemical and pharmaceutical plants.
- Power generation and distribution monitoring.
- Water and wastewater management infrastructure.
Technical Specifications
Category
Specification
| Manufacturer |
Honeywell |
| Part Number/Model |
CC-SCMB03 |
| Series |
Experion PKS / C300 Series |
| Module Type |
C300 Memory Backup Assembly |
| Shipping Weight |
2.0 kg |
| Operating Temperature Range |
0 to 60 degC |
| Storage Temperature Range |
-40 to 85 degC |
| Relative Humidity |
5% to 95% non-condensing |
Installation Guidelines
-
ESD Precautions: Wear an approved electrostatic discharge (ESD) wrist strap connected to a reliable ground point before handling or installing the module.
-
Mounting: Ensure the alignment pins on the assembly match the guide slots of the controller platform. Tighten all securing screws uniformly to guarantee proper physical and electrical contact.
-
Diagnostic Monitoring: Upon installation, verify that the Experion PKS system console recognizes the new backup assembly and that no hardware faults or low charge levels are reported.