The Honeywell FC-SCNT02 is a controller module engineered for the Safety Manager SC system. It serves as a functional replacement for the FC-SCNT01 module within safety system architectures and can be swapped online without interrupting process operations. In redundant Safety Manager SC (SMSC) controller configurations, the module functions side-by-side with an existing FC-SCNT01 module.
The module supports DNP3 protocol outstation functionality starting with Safety Manager SC release R212, allowing the Safety Manager SC to operate as a DNP3 Outstation while communicating with a DNP3 Master such as an Experion Server or ControlEdge RTU. It also functions as a direct spare part for the FC-SCNT01 module, maintaining full operational feature parity with the legacy module.
Features
Direct functional replacement and spare part for the FC-SCNT01 controller module
Online replacement capability without disrupting running operations
Redundant operations support, functioning alongside an FC-SCNT01 module in SMSC controllers
Integrated DNP3 protocol outstation support (requires release R212)
Compatible with Safety Manager SC software release R200.2 and higher
Applications
Safety Instrumented Systems (SIS) and Emergency Shutdown (ESD) applications
Industrial SCADA telecontrol communication networks utilizing DNP3 protocol outstation integration
Technical Specifications
Parameter
Specification
Manufacturer
Honeywell
Model
FC-SCNT02
Part Mumber
51460114-17
System Compatibility
Safety Manager SC
Supported Software Release
Safety Manager SC R200.2 and higher
DNP3 Protocol Support Release
Safety Manager SC R212 and higher
Module Replacement Mode
Online replacement / Hot Swap capable
Redundancy Support
Dual redundant controller configuration with FC-SCNT01
Installation Guidelines
Online Replacement: The module can be installed or replaced online in a running Safety Manager SC system without requiring a shutdown.
Redundant Pair Coexistence: In redundant controller setups, an FC-SCNT02 module can be installed alongside an existing FC-SCNT01 module.
Software Prerequisites: Verify that the Safety Manager SC system software is at release R200.2 or higher before module installation, and release R212 or higher if utilizing DNP3 outstation features.
FAQ
Can this controller module replace an older FC-SCNT01 module?
Yes, the module is a direct functional replacement and spare part for the FC-SCNT01 module and can operate online within the system.
Can the module operate alongside an existing FC-SCNT01 in a redundant system?
Yes, it can function with another FC-SCNT01 module in a redundant Safety Manager SC controller configuration.
Which software release is required to support this controller module?
The module is supported on Safety Manager SC release R200.2 and higher.
Which software release is required for DNP3 protocol outstation support?
DNP3 protocol outstation functionality is supported starting with Safety Manager SC release R212.
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.