Honeywell

Honeywell MC-TAOX52 51304335-275 Analog Output FTA

SKU MC-TAOX52 51304335-275

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: MC-TAOX52 51304335-275
  • Origin United States
  • Product Type: Analog Output Modules
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.52 kg
  • Dimensions: 30.6 x 12.0 x 8.0 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The Honeywell MC-TAOX52 (Model 51304335-275) is an 8-channel Analog Output Field Termination Assembly (FTA) designed for use within Honeywell TDC 3000 and related distributed control systems. This hardware interface serves as a reliable termination point for connecting control system output signals directly to final control elements such as actuators, control valves, and positioners in industrial process environments.

Built to interface with standard Honeywell I/O cards, the MC-TAOX52 translates controller commands into precise analog current or voltage signals. The assembly helps streamline field cabling, organize signal distribution, and maintain loop integrity in continuous manufacturing plants, chemical processing facilities, and power generation installations.

Features

  • Provides 8 dedicated analog output channels for process control loops
  • Designed for direct integration with Honeywell TDC 3000 and UCN control architectures
  • Facilitates organized field wiring termination to reduce installation and maintenance time
  • Rugged industrial construction suited for standard control room or rack enclosure mounting
  • Ensures accurate signal transmission between the control system and field actuators

Applications

  • Chemical and petrochemical processing plants
  • Oil and gas upstream and downstream facilities
  • Power generation and utility systems
  • Continuous pulp and paper manufacturing lines
  • Water and wastewater treatment installations

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model MC-TAOX52
Part Number 51304335-275
Product Type Analog Output FTA
Channel Count 8 Channels
System Compatibility Honeywell TDC 3000 / UCN
Country of Origin United States

Installation Guidelines

  1. Verify that the control system power and associated loop power supplies are de-energized before handling the assembly.
  2. Inspect the physical unit for any transit damage or terminal block defects.
  3. Mount the FTA securely onto the designated DIN rail or cabinet mounting plate within the marshalling panel.
  4. Connect field wiring to the appropriate terminal blocks, ensuring correct polarity and shielding per loop diagrams.
  5. Connect the system-side cable from the I/O module to the FTA connector.
  6. Energize the system and verify loop operation and channel accuracy from the engineering station.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What system is the Honeywell MC-TAOX52 51304335-275 designed for?
The Honeywell MC-TAOX52 51304335-275 is designed for integration into Honeywell TDC 3000 and Universal Control Network (UCN) distributed control systems.
How many channels does this analog output FTA support?
The Honeywell MC-TAOX52 provides 8 dedicated analog output channels for terminating control signals to field devices.
What is the primary function of an FTA like the MC-TAOX52?
The Honeywell MC-TAOX52 acts as a field termination assembly that bridges control system I/O electronics with field-side cabling connected to valves, actuators, and other control elements.
Is the Honeywell MC-TAOX52 suitable for new installations?
While the Honeywell MC-TAOX52 is commonly deployed as a replacement or expansion component in legacy TDC 3000 architectures, availability may depend on surplus or refurbished inventory channels.
Reviews

MC-TAOX52 51304335-275

Stock & lead time on request

Call
1 of 3

Honeywell MC-TAOX52 51304335-275 Analog Output FTA

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: MC-TAOX52 51304335-275

  • Country of origin:United States

  • Product Type: Analog Output Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 520g

  • Dimensions: 30.6 x 12.0 x 8.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Honeywell MC-TAOX52 (Model 51304335-275) is an 8-channel Analog Output Field Termination Assembly (FTA) designed for use within Honeywell TDC 3000 and related distributed control systems. This hardware interface serves as a reliable termination point for connecting control system output signals directly to final control elements such as actuators, control valves, and positioners in industrial process environments.

Built to interface with standard Honeywell I/O cards, the MC-TAOX52 translates controller commands into precise analog current or voltage signals. The assembly helps streamline field cabling, organize signal distribution, and maintain loop integrity in continuous manufacturing plants, chemical processing facilities, and power generation installations.

Features

  • Provides 8 dedicated analog output channels for process control loops
  • Designed for direct integration with Honeywell TDC 3000 and UCN control architectures
  • Facilitates organized field wiring termination to reduce installation and maintenance time
  • Rugged industrial construction suited for standard control room or rack enclosure mounting
  • Ensures accurate signal transmission between the control system and field actuators

Applications

  • Chemical and petrochemical processing plants
  • Oil and gas upstream and downstream facilities
  • Power generation and utility systems
  • Continuous pulp and paper manufacturing lines
  • Water and wastewater treatment installations

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model MC-TAOX52
Part Number 51304335-275
Product Type Analog Output FTA
Channel Count 8 Channels
System Compatibility Honeywell TDC 3000 / UCN
Country of Origin United States

Installation Guidelines

  1. Verify that the control system power and associated loop power supplies are de-energized before handling the assembly.
  2. Inspect the physical unit for any transit damage or terminal block defects.
  3. Mount the FTA securely onto the designated DIN rail or cabinet mounting plate within the marshalling panel.
  4. Connect field wiring to the appropriate terminal blocks, ensuring correct polarity and shielding per loop diagrams.
  5. Connect the system-side cable from the I/O module to the FTA connector.
  6. Energize the system and verify loop operation and channel accuracy from the engineering station.
Loading product navigation…

What system is the Honeywell MC-TAOX52 51304335-275 designed for?

The Honeywell MC-TAOX52 51304335-275 is designed for integration into Honeywell TDC 3000 and Universal Control Network (UCN) distributed control systems.

How many channels does this analog output FTA support?

The Honeywell MC-TAOX52 provides 8 dedicated analog output channels for terminating control signals to field devices.

What is the primary function of an FTA like the MC-TAOX52?

The Honeywell MC-TAOX52 acts as a field termination assembly that bridges control system I/O electronics with field-side cabling connected to valves, actuators, and other control elements.

Is the Honeywell MC-TAOX52 suitable for new installations?

While the Honeywell MC-TAOX52 is commonly deployed as a replacement or expansion component in legacy TDC 3000 architectures, availability may depend on surplus or refurbished inventory channels.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit