Description

Honeywell SC-UCMX02 51307195-276 is a modular, scalable process controller designed for remote automation and control applications. Powered by a dual-core ARM Cortex-A9 32-bit CPU running at 667 MHz, it provides integrated processing and direct field connections with 28 mixed onboard I/O channels. The SC-UCMX02 non-redundant controller includes 256 MB DRAM, 256 MB Flash memory, and 4 Mbits of battery-free nonvolatile memory. Built-in serial and Ethernet communication ports support standard industrial protocols including Modbus, DNP3, HART-IP, IEC 60870-5-104, and MQTT/Sparkplug. Designed for harsh remote operational environments, the unit operates in extended temperatures from -40 degC to 75 degC with conformal-coated assemblies and transient voltage suppression on all I/O channels and serial/Ethernet communication ports.

Features

  • Processor & Memory: Dual Core ARM Cortex-A9 (32-bit) 667 MHz processor with 256 MB DRAM, 256 MB Flash, and 4 Mbits nonvolatile memory requiring no battery backup.
  • Onboard Mixed I/O: 28 integrated I/O channels including 8 Analog Inputs (HART), 2 Analog Outputs (HART), 10 Digital Inputs, 6 Digital Outputs, and 2 Pulse/Digital Inputs.
  • Ethernet Communications: 2 ANSI/IEEE 802.3 10/100BaseTx RJ45 ports with 1500 V RMS isolation and transient voltage suppression.
  • Serial Interfaces: 2 RS232 ports (RJ45, full-duplex, up to 15m) and 2 RS485 ports (screw terminals, 2-wire half-duplex, up to 1200m).
  • Protocol Support: Supports Modbus RTU/ASCII/TCP, Enron Modbus, DNP3 TCP (Level 3+ Outstation/Master), IEC60870-5-104, MQTT (Sparkplug B), and HART-IP.
  • Expandability: Supports up to 30 expansion I/O modules across up to 5 expansion rows.
  • Datalogging: Event logs stored on internal Flash memory (up to 200,000 events) or an optional SD card (up to 500,000 events, up to 32GB Class 6/10).
  • Ruggedized Construction: Operates across -40 degC to 75 degC, compliant with ANSI/ISA S71.04 Class G3 conformal coating and IEC 60068-2-6 vibration resistance.

Applications

  • Remote Terminal Unit (RTU) process control
  • Oil and gas custody transfer and Electronic Flow Metering (EFM)
  • Wellhead control and artificial lift systems (Plunger Lift)
  • Pipeline monitoring and remote infrastructure automation
  • Remote asset monitoring via HART-IP and field device integration

Ordering Information

Model Number Description
SC-UCMX02 Non-redundant Controller with 28 mixed onboard I/O with 256MB DRAM

Technical Specifications

Category Parameter Specification
System Processor Dual Core ARM Cortex-A9 Core (32 bit) 667 MHz
  Dynamic Memory (RAM) 256 MB
  Program Memory (Flash) 256 MB
  Nonvolatile Memory 4 Mbits (20+ years data life, no battery required)
  Real-Time Clock Resolution 1 ms
  Execution Cycle Time >= 20 ms
Power Requirements Input Voltage 18 to 30 VDC (Rated 24 VDC +/- 25%)
  Maximum Input Current 1.20 A at 30 VDC (controller plus 9 IOMs)
  Maximum Ripple Voltage 120 mVpp
  Power Consumption Min 1.7 W (no expansion IOMs) / Max 3.4 W (with expansion IOMs)
Onboard I/O - Analog Input Channels 8 (Single ended, 4-20mA or 1-5VDC configurable, HART enabled)
  Resolution / Accuracy 16-bit / +/-0.1% at 25 degC (+/-0.2% -40 degC to 75 degC)
Onboard I/O - Analog Output Channels 2 (Source, 4-20mA, HART enabled)
  Resolution / Accuracy 12-bit / +/-0.2% at 25 degC (+/-0.3% -40 degC to 75 degC)
Onboard I/O - Digital Input Channels 10 (Sink / dry contact, 24VDC +/-10% external supply)
  Thresholds Guaranteed ON >= 12 VDC, Guaranteed OFF <= 4 VDC
Onboard I/O - Digital Output Channels 6 (Sink / voltage free, 24VDC, max 80 mA load per channel)
  On-State Voltage Max 1 VDC at 80 mA max load current
Onboard I/O - Pulse Input Channels 2 (Sink, 0 to 10 kHz, 5 to 10 V peak to peak input)
Communication - Ethernet Ports / Speed 2 x RJ45 ports / 10/100BaseTx auto-detecting
  Isolation 1500 V RMS for 1 minute, 60 Hz
Communication - Serial RS232 Ports 2 x RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR/RI, GND), full duplex
  RS485 Ports 2 x Screw terminals (GND, 485+, 485-, termination, chassis), 2-wire half-duplex
  Baud Rates 300 to 115200 bps
Mechanical & Environmental Mounting DIN rail (TH35-7.5)
  Operating Temperature -40 degC to 75 degC
  Storage Temperature -40 degC to 85 degC
  Operating Humidity 5% to 95% RH (non-condensing)
  Dimensions (L x W x H) 190 mm x 99 mm x 141 mm
  Weight 700 g

Connections/Interfaces

Connector Pin Function
Power Terminals 18-30 VDC Power Input
RS485 Port 1 & 2 Screw terminals: GND, 485+, 485-, Termination, Chassis
RS232 Port 1 & 2 RJ45: TD, RD, CTS, RTS, CD, DTR, DSR/RI, GND
Ethernet Port 1 & 2 RJ45 shielded connectors (auto-crossover)
Onboard IOM 28-channel field terminal connections
SD Card Slot SD Card interface
Expansion Interface Expansion I/O Connector

Installation Guidelines

  • Mounting: Install on standard TH35-7.5 DIN rail in a vertical orientation to maintain natural thermal convection.
  • Power Supply: Connect an external 18 to 30 VDC power supply to the dedicated power terminals on the controller IOTA.
  • Grounding & Shielding: Ensure all RJ45 Ethernet connectors use shielded cabling and connect chassis drain wires on RS485 terminal blocks to mitigate electrical noise.
  • Transient Suppression: Built-in transient voltage suppression is present on all I/O channels and communication interfaces.
  • Expansion Cabling: Connect expansion I/O rows using standard CAT-5 cables routed between left and right end plates up to a maximum distance of 100 meters.

Compliance and Certifications

  • Hazardous Locations: CSA Class I, Division 2, Group A, B, C, D T4; Ex ec IIC T4 Gc; ATEX II 3 G Ex ec IIC T4 Gc; IECEx Ex ec IIC T4 Gc
  • UL Standards: UL121201, UL 60079-0, UL 60079-7, UL Std. No. 61010-1
  • CSA Standards: CAN/CSA-C22.2 No. 213-17, CAN/CSA-C22.2 No. 61010-1-12, CAN/CSA-C22.2 No. 60079-0:15, CAN/CSA-C22.2 No. 60079-7:16, CAN/CSA C22.2 No. 0-10
  • ATEX/UKCA Standards: EN IEC60079-0:2018, EN 60079-7:2015+A1:2018
  • IEC Standards: IEC 60079-0 (2017), IEC 60079-7:2017
  • CE Directives: LVD EN 61010-1 (2010), EMC EN 61326-1 (2013)
  • Marine Certification: Bureau Veritas (BV), DNV GL
  • Security Certification: ISASecure / IEC 62443 Conformance (Security Level 2)
  • Environmental & Environmental Standards: UL 94 V-0 Flammability, ANSI/ISA S71.04 Class G3 Conformal Coating, IEC 60068-2-6 Vibration
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell SC-UCMX02 51307195-276 ControlEdge 2020 Non Redundant Controller

What is the operating temperature range for the controller?

The module operates in temperatures ranging from -40 degC to 75 degC.

How many onboard I/O channels are integrated into this unit?

The device features 28 onboard mixed I/O channels, including 8 AI, 2 AO, 10 DI, 6 DO, and 2 Pulse/DI channels.

What power input voltage is required for operation?

The power supply requirement is 18 to 30 VDC, with a nominal rating of 24 VDC.

Which communication protocols are natively supported on Ethernet and serial ports?

Supported protocols include Modbus TCP/RTU/ASCII, DNP3 TCP, Enron Modbus, HART-IP, IEC 60870-5-104, and MQTT (Sparkplug B).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...