Honeywell

Honeywell TC-IDJ161 16-Point 24VDC Isolated Discrete Input Module

SKU TC-IDJ161

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: TC-IDJ161

  • Country of origin:United States

  • Product Type: Discrete Input Modules

  • Payment: T/T, Western Union

  • Weight: 250g

  • Dimensions: 145 mm x 38 mm x 137 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell TC-IDJ161 (TK-IDJ161) is a 16-point isolated discrete input module engineered for industrial control systems. It provides reliable digital signal acquisition for PLCs and process automation platforms operating at a nominal voltage of 24 VDC. Each input channel is individually isolated, delivering channel-to-channel and user-to-system electrical isolation to protect automation infrastructure from ground loops, voltage transients, and field interference.

Features

  • 16 Individually Isolated Channels: Complete channel-to-channel and user-to-system isolation for enhanced transient protection and noise immunity.
  • Wide On-State Operating Range: Accepts field input signals ranging from 10 VDC to 30 VDC.
  • Programmable Filter Delays: Features selectable Off-to-On (1 ms, 2 ms) and On-to-Off (1, 2, 9, 18 ms) digital delay settings to suppress field contact bounce.
  • IEC Type 1+ Input Compatibility: Designed to interface seamlessly with standard industrial discrete sensing devices and switches.
  • Robust Transient Handling: Designed with 250 mA peak inrush current capacity (decaying to <37% within 22 ms without activating input state).

Applications

  • Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC)
  • Industrial discrete field signal monitoring and event logging
  • High-noise environments requiring individual channel galvanic isolation
  • Sensing systems utilizing proximity switches, pushbuttons, and auxiliary contacts

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model TC-IDJ161 (TK-IDJ161)
Number of Points 16 (individually isolated)
Nominal Input Voltage 24 VDC
On-State Voltage Range 10–30 VDC
Off-State Voltage (Maximum) 5 VDC
On-State Current (Minimum) 2.0 mA @ 10 VDC
Off-State Current (Maximum) 1.5 mA
Short/Inrush Current 250 mA peak (decaying to <37% in 22 ms, without activation)
Input Impedance (Maximum) 31 KΩ @ 60 Hz
Input Delay Time (Off to On) Programmable: 1 ms & 2 ms; Hardware delay: 1 ms max plus filter time
Input Delay Time (On to Off) Programmable: 1, 2, 9, 18 ms; Hardware delay: 4 ms max plus filter time
Power Dissipation 5.0 W max
Input Compatibility IEC Type 1+
Isolation Voltage (Channel to Channel) 100% tested at 2546 VDC for 1s
Isolation Voltage (User to System) 100% tested at 2546 VDC for 1s
Connection TC-TBCH, 36-position terminal block

Installation Guidelines

  • Terminal Block Assembly: Connect field wiring to the compatible TC-TBCH 36-position terminal block prior to seating onto the module frame.
  • Wiring & Noise Mitigation: Route low-voltage 24 VDC input signal cables separately from high-voltage AC lines and high-current power cables to minimize electromagnetic interference.
  • System Grounding: Ensure proper cabinet and chassis grounding to maintain high isolation integrity and protection against system-level electrostatic discharge.
  • Heat Dissipation: Ensure adequate enclosure ventilation to maintain optimal operational temperatures under maximum power dissipation conditions (5.0 W max).

FAQ

How many input points are provided on the module?

The module features 16 individually isolated discrete input points.

What is the allowable operating voltage range for an On-State signal?

The On-State input voltage range is 10 VDC to 30 VDC, with a nominal rating of 24 VDC.

What isolation voltage ratings does the device support?

Both channel-to-channel and user-to-system isolation are 100% tested at 2546 VDC for 1 second.

Which terminal block is used for field wiring connections?

Field wiring connects to the device using a TC-TBCH 36-position terminal block.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.