First TwinCAT PLC Project on a Beckhoff IPC
Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.
Manufacturer: Honeywell
Product No.: 50124386-001
Country of origin:United States
Product Type: Actuator Mounting Brackets
Payment: T/T, Western Union
Weight: 3000g
Dimensions: 170 mm x 138 mm x 138 mm
Shipping port: Xiamen
Warranty: 12 months
Engineered for heavy-duty industrial valve and damper positioning systems, the Honeywell 50124386-001 serves as a robust mounting bracket solution designed specifically for the LTA, V51, and 5197 series actuator assemblies. This industrial-grade mechanical hardware ensures precise physical alignment, minimizing shaft runout and mechanical wear under high-torque operations.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Honeywell |
| Part Number / SKU | 50124386-001 |
| Compatible Actuators | Honeywell LTA, V51, and 5197 Series |
| Material | Heavy-gauge structural steel alloy |
| Maximum Torque Rating | Supports up to 150 in-lb operating loads |
| Operating Temperature Limits | -40 to +70 degC (-40 to +158 degF) |
| Storage Temperature Limits | -40 to +80 degC (-40 to +176 degF) |
| Approximate Physical Dimensions | 170 mm x 138 mm x 138 mm (6-11/16 x 5-29/64 x 5-29/64 inches) |
| Net Weight | 1.4 kg (3.0 lbs) |
| Shipping Weight (Calculated) | 3.0 kg |
This mounting hardware kit is engineered to drop directly into standard industrial footings for the V51 and 5197 Honeywell motorized actuators. It serves as a direct upgrade to legacy structural brackets that lack the structural reinforcement profiles required for high-duty-cycle modulating dampers.
Ensure that mounting surfaces are completely flat prior to bolting down the bracket. Any deflection or twist introduced into the bracket base during installation will misalign the linkage or actuator output shaft, leading to premature bearing failure in the drive assembly. If deployed in applications exceeding 150 in-lb peak dynamic load, additional external structural supports are required.
Verify shaft concentricity using a dial indicator during initial setup. Radial runout must not exceed tolerances specified in the actuator manual. Tighten all assembly fasteners in an alternating pattern to distribute torque evenly and prevent structural binding.
Align the mounting bracket base holes with the actuator installation plate on the process valve or damper frame.
Secure the bracket using high-tensile mounting bolts (Grade 5 or higher recommended) and apply a medium-strength thread-locking compound.
Mount the Honeywell actuator to the bracket top face, ensuring complete alignment of keyways and connecting shafts before final torque is applied.
Global Express Shipping
Returns & Warranty

Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|