Honeywell

Honeywell 50124386-001 LTA V51/5197 Actuator Mounting Bracket

SKU 50124386-001

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 50124386-001

  • Country of origin:United States

  • Product Type: Actuator Mounting Brackets

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Dimensions: 170 mm x 138 mm x 138 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for heavy-duty industrial valve and damper positioning systems, the Honeywell 50124386-001 serves as a robust mounting bracket solution designed specifically for the LTA, V51, and 5197 series actuator assemblies. This industrial-grade mechanical hardware ensures precise physical alignment, minimizing shaft runout and mechanical wear under high-torque operations.

Features

  • Precision-machined steel alloy construction for high torsional rigidity.
  • Corrosion-resistant surface finish optimized for harsh process environments.
  • Pre-drilled mounting patterns ensuring exact alignment with V51 and LTA actuator footprints.
  • Heavy-gauge structural design rated to withstand peak mechanical torque applications.

Applications

  • Industrial combustion air damper control linkages.
  • Heavy HVAC damper actuator positioning.
  • Process control valve bracket replacements.
  • High-vibration fan and ventilation plant installations.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Part Number / SKU 50124386-001
Compatible Actuators Honeywell LTA, V51, and 5197 Series
Material Heavy-gauge structural steel alloy
Maximum Torque Rating Supports up to 150 in-lb operating loads
Operating Temperature Limits -40 to +70 degC (-40 to +158 degF)
Storage Temperature Limits -40 to +80 degC (-40 to +176 degF)
Approximate Physical Dimensions 170 mm x 138 mm x 138 mm (6-11/16 x 5-29/64 x 5-29/64 inches)
Net Weight 1.4 kg (3.0 lbs)
Shipping Weight (Calculated) 3.0 kg

Alternative Models & Compatibility

This mounting hardware kit is engineered to drop directly into standard industrial footings for the V51 and 5197 Honeywell motorized actuators. It serves as a direct upgrade to legacy structural brackets that lack the structural reinforcement profiles required for high-duty-cycle modulating dampers.

Application Pitfalls & Engineering Notes

Ensure that mounting surfaces are completely flat prior to bolting down the bracket. Any deflection or twist introduced into the bracket base during installation will misalign the linkage or actuator output shaft, leading to premature bearing failure in the drive assembly. If deployed in applications exceeding 150 in-lb peak dynamic load, additional external structural supports are required.

Commissioning & Alignment Tips

Verify shaft concentricity using a dial indicator during initial setup. Radial runout must not exceed tolerances specified in the actuator manual. Tighten all assembly fasteners in an alternating pattern to distribute torque evenly and prevent structural binding.

Installation Guidelines

CRITICAL WARNING: Prior to mounting or performing maintenance on the actuator assembly, disconnect all electrical power sources and isolate any coupled process control equipment. Failure to de-energize mechanical drives can result in unexpected actuator cycle triggers and severe physical injury.
1

Align the mounting bracket base holes with the actuator installation plate on the process valve or damper frame.

2

Secure the bracket using high-tensile mounting bolts (Grade 5 or higher recommended) and apply a medium-strength thread-locking compound.

3

Mount the Honeywell actuator to the bracket top face, ensuring complete alignment of keyways and connecting shafts before final torque is applied.

FAQ

Which Honeywell actuator lines are compatible with this mounting bracket assembly?

This bracket is designed specifically for Honeywell LTA, V51, and 5197 series industrial valve and damper actuators.

What is the maximum torque capacity supported by this mechanical mounting bracket?

It is structurally optimized for heavy industrial operations, handling peak actuator output loads of up to 150 in-lb safely.

Does this mounting bracket require specific environmental considerations?

No. The rugged steel alloy construction and specialized coating allow it to operate reliably in harsh ambient environments ranging from -40 to +70 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...