The Honeywell TC-PCIC02 (part number 93404872) is a dedicated ControlNet Interface Module engineered for integration within Honeywell Experion control architectures. This hardware component serves as a primary communication bridge, connecting system controllers and nodes to the high-speed ControlNet deterministic network. It is utilized in distributed control system (DCS) environments to manage real-time I/O data exchanges, peer-to-peer messaging, and controller scheduling.

The module facilitates deterministic network communications required for time-critical industrial automation tasks. By offloading network traffic management from the main processing unit, the TC-PCIC02 helps maintain low latency and predictable data updates across the control network infrastructure. It is designed for standard industrial chassis mounting within compatible Honeywell controller racks.

Features

  • Provides deterministic ControlNet communication for Honeywell Experion systems
  • Supports scheduled and unscheduled data transfer over coaxial or fiber media
  • Enables peer-to-peer controller communication and supervisory data access
  • Designed for direct insertion into standard Honeywell Series C or Experion chassis slots
  • Integrated diagnostic indicators for network status and module health monitoring

Applications

  • Continuous process control in chemical and petrochemical plants
  • Power generation and distribution monitoring systems
  • Oil and gas upstream and downstream automation
  • Discrete manufacturing lines requiring deterministic fieldbus integration

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Exact Model TC-PCIC02
Catalog / Part Number 93404872
Product Type ControlNet Interface Module
System Family Experion LS / Experion PKS
Communication Protocol ControlNet (Coaxial BNC interface)
Mounting Type Chassis slide-in module
Country of Origin United States
Dimensions 2.1 cm x 18.3 cm x 12.5 cm
Net Weight 0.12 kg

Connections / Interfaces

Interface Function
ControlNet Port (BNC) Connection to the dual-redundant or single ControlNet coaxial cable network
Backplane Connector Power distribution and internal communication with the controller and chassis

Installation Guidelines

  1. Verify that the part number on the module matches your system engineering documentation.
  2. Ensure system power is de-energized before inserting or removing any module from the chassis.
  3. Inspect the backplane pins and module connector for any debris or physical damage.
  4. Slide the TC-PCIC02 module smoothly into the designated chassis slot until fully seated.
  5. Secure any retention screws or latching mechanisms.
  6. Connect the ControlNet coaxial cable securely to the BNC port.
  7. Restore power and verify module status LEDs indicate normal operation and network communication.

FAQ

What is the Honeywell TC-PCIC02 93404872 and what is its primary function?

The Honeywell TC-PCIC02 93404872 is a dedicated ControlNet Interface Module engineered for integration within Honeywell Experion control architectures. This hardware component serves as a primary communication bridge, connecting system controllers and nodes to the high-speed ControlNet deterministic network. It is utilized in distributed control system (DCS) environments to manage real-time I/O data exchanges, peer-to-peer messaging, and controller scheduling.

Which system families and architectures are compatible with this interface module?

The Honeywell TC-PCIC02 93404872 is specifically designed for the Honeywell Experion LS and Experion PKS system families. It allows for direct insertion into standard Honeywell Series C or Experion chassis slots. This ensures seamless integration and high-speed communication within existing industrial automation infrastructures.

How does the Honeywell TC-PCIC02 handle network traffic and communications?

The Honeywell TC-PCIC02 93404872 facilitates deterministic network communications required for time-critical industrial automation tasks. By offloading network traffic management from the main processing unit, the module helps maintain low latency and predictable data updates across the control network. Additionally, it supports both scheduled and unscheduled data transfer over coaxial or fiber media.

What are the physical dimensions and weight of this control hardware?

The Honeywell TC-PCIC02 93404872 features compact dimensions measuring 2.1 cm x 18.3 cm x 12.5 cm for efficient rack utilization. It is a lightweight unit with a net weight of approximately 0.12 kg. These physical characteristics make it ideal for standard industrial chassis slide-in mounting within compatible controller racks.

What connection interfaces are available on the Honeywell TC-PCIC02?

The Honeywell TC-PCIC02 93404872 includes a ControlNet BNC port for connecting to dual-redundant or single ControlNet coaxial cable networks. It also features a robust backplane connector that handles power distribution and internal communication with the controller and chassis. Furthermore, integrated diagnostic indicators are built into the module for real-time network status and health monitoring.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 2
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.