Honeywell

Honeywell FC-SAI-1620M Safe High-Density Analog Input Module

SKU FC-SAI-1620

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: FC-SAI-1620
  • Origin United States
  • Product Type: Analog input module
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.35 kg
  • Dimensions: 20 x 130 x 190 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FC-SAI-1620M Safe High-Density Analog Input Module

Quantity

Product Description

Description

The Honeywell FC-SAI-1620M is a conformal-coated, safe high-density analog input module engineered for high-integrity process safeguarding and critical automation applications within the Honeywell Safety Manager system platform. Operating on a 24 Vdc power supply, this module provides 16 dedicated analog input channels designed to interface with 0(4)–20 mA field transmitters and process instrumentation. It plays a key role in acquiring analog process variables and routing signal data over the internal Safety Manager IO Bus directly to the Quad Processor Pack (QPP) for high-integrity safety logic processing.

Designed to meet stringent functional safety standards up to SIL3 per IEC 61508, the FC-SAI-1620M executes continuous internal diagnostic self-tests within a defined Diagnostic Test Interval (DTI). Its conformal coating protects the internal Eurocard circuit board against harsh industrial environments, ensuring reliable long-term performance in Emergency Shutdown (ESD), Fire and Gas (F&G) detection, and Burner Management Systems (BMS).

Features

  • Conformal Coating: Formulated with protective coating (FC prefix) to resist environmental contaminants, moisture, and corrosive airborne elements in harsh plant environments.
  • High-Density Channel Layout: Features 16 safe analog input channels within a compact 3U / 4HP Eurocard form factor to maximize cabinet rack space.
  • SIL3 Functional Integrity: Fully certified for use in safety instrumented functions up to Safety Integrity Level 3 in both single and Quadruple Modular Redundant (QMR) architectures.
  • Comprehensive Self-Diagnostics: Conducts automatic, background diagnostic testing of internal circuitry and signal paths within the Diagnostic Test Interval (DTI) to detect and isolate hardware anomalies safely.
  • Field Termination Assembly Integration: Connects seamlessly to external Field Termination Assemblies (such as TSAI-1620m or TSHART-1620m) using standard System Interconnection Cables (FS-SIC-0001).
  • Hot-Swappable Subsystem Architecture: Integrates into the Safety Manager IO chassis backplane via standard 32-pin DIN 41612F connectors with key coding to prevent improper module insertion.

Applications

  • Process Safeguarding & ESD: Monitors critical process instrumentation (pressure, temperature, flow, level) for Emergency Shutdown loops.
  • Fire & Gas (F&G) Monitoring: Interfaces with analog gas and flame detectors in hydrocarbon processing and off-shore facilities.
  • Burner Management Systems (BMS): Safe tracking of fuel pressures, airflow, and flame intensity signals in boiler and furnace control applications.
  • Turbine & Compressor Protection: Continuous monitoring of operating variables to prevent surge, overpressure, or mechanical overspeed conditions.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model FC-SAI-1620M
Part Number Prefix FC (Conformal Coated)
System Platform Safety Manager
Module Type Safe High-Density Analog Input Module
Number of Channels 16 channels
Nominal Voltage 24 Vdc
Signal Range 0–20 mA / 4–20 mA
Safe Failure Fraction (SFF) ≥ 99%
Safety Integrity Level Up to SIL3 (IEC 61508 / ISA S84.01)
Module Form Factor Eurocard (100 x 160 mm / 3.94 x 6.30 in)
Panel Dimensions Height: 3U (3 HE), Width: 4HP (4 TE)
Connector Type 32-pin DIN 41612F connector
Operating Temperature -5 degC to 70 degC (14 degF to 158 degF) ambient
Storage Temperature -25 degC to 80 degC (-13 degF to 176 degF)
Relative Humidity 5% to 95%, non-condensing
Vibration Tolerance IEC 60068-2-6; 1 G at 57 Hz to 150 Hz; 0.075 mm from 10 Hz to 57 Hz
Shock Resistance IEC 60068-2-27; 15 G for 11 ms, 3 axes

Connections / Interfaces

Connection Point Description
Backplane Connector Standard 32-pin DIN 41612F Eurocard interface with mechanical keying
System Cable Interface Connects to Field Termination Assembly (TSAI-1620m / TSHART-1620m) via FS-SIC-0001 System Interconnection Cable
Primary Bus Link Communicates with the Control Processor via the Safety Manager horizontal and vertical IO Bus

Installation Guidelines

  1. Pre-Installation Inspection: Verify that the module model code (FC-SAI-1620M) matches project drawings and check the conformal coating for any physical damage prior to installation.
  2. Power Off Rack Section: Ensure supply power to the target slot or chassis segment is turned off or isolated according to plant safety procedures before inserting non-redundant hardware.
  3. Align and Seat Module: Carefully align the Eurocard edges with the card guides in the 3U slot of the IOCHAS chassis. Push firmly until the 32-pin DIN 41612F connector seats completely into the backplane.
  4. Secure Fasteners: Tighten top and bottom retaining screws on the front panel to guarantee proper grounding and mechanical stability under vibration.
  5. Cabling to FTA: Connect the System Interconnection Cable (FS-SIC-0001) from the rear backplane port to the corresponding Field Termination Assembly (TSAI-1620m or TSHART-1620m).

Configuration / Commissioning / Replacement

Configuration Guidelines

  • Define channel parameters and signal ranges (0–20 mA or 4–20 mA) in the Safety Builder software environment using Point Configurator.
  • Configure channel-specific fault reaction states (e.g., Top Scale, Bottom Scale, Scan, or Hold) according to loop safety requirements.

Commissioning Recommendations

  • Perform field signal loop checks from the transmitter through the FTA to the Safety Builder station to verify live reading accuracy.
  • Validate diagnostic trip thresholds and verify that input discrepancies trigger appropriate alarms on the station HMI without tripping operational process loops prematurely.

Replacement Recommendations

  • Parameter Backup: Confirm the project logic and I/O map database are fully backed up in Safety Builder prior to replacing an existing module.
  • Hardware Matching: Ensure the replacement module carries the conformal-coated FC-SAI-1620M designation to maintain environmental resistance ratings in critical areas.

Compliance and Certifications

  • Functional Safety: Certified by TÜV to IEC 61508 Parts 1–7 (SIL3 capable) and ANSI/ISA S84.01.
  • Standard ESD/ESD: Compliant with DIN V VDE 19250, DIN V VDE 0801, and UL 1998 / UL 508.
  • Hazardous Locations: CSA certified (C22.2 No. 142-M1987) and FM 3611 Class I, Division 2 compliant.
  • CE Compliance: Conforms to European Directives 89/336/EEC (EMC) and 73/23/EEC (Low Voltage Directive).
  • EMC Immunity: Tested to IEC 61000-4-2 (ESD Level 4), IEC 61000-4-3 (Radiated), IEC 61000-4-4 (Burst Level 3), and IEC 61000-4-5 (Surge Level 3).
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell FC-SAI-1620M analog input module?
The Honeywell FC-SAI-1620M is a high-density, 16-channel safe analog input module designed to interface 0(4)–20 mA field signals with the Honeywell Safety Manager system for SIL3 safety-critical control and process safeguarding applications.
What does the 'FC' prefix indicate in the Honeywell FC-SAI-1620M model number?
The 'FC' prefix designates that the Honeywell FC-SAI-1620M module features conformal coating on its electronic assemblies, providing enhanced resistance against humidity, moisture, and corrosive atmospheric contaminants compared to non-coated 'FS' models.
Which Field Termination Assemblies (FTAs) are compatible with the Honeywell FC-SAI-1620M?
The Honeywell FC-SAI-1620M connects to field wiring via dedicated Field Termination Assemblies, such as the TSAI-1620m for standard 0(4)–20 mA signals or the TSHART-1620m for HART-pass-through applications, using system interconnection cables.
What happens if a channel fault is detected on the Honeywell FC-SAI-1620M?
When an internal or signal path fault is detected during continuous self-testing, the Honeywell FC-SAI-1620M isolates the affected signal and sets the channel to its user-configured fault reaction state, such as Top Scale, Bottom Scale, Scan, or Hold.
Reviews

FC-SAI-1620

Stock & lead time on request

Call
1 of 3

Honeywell FC-SAI-1620M Safe High-Density Analog Input Module

Only 3 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FC-SAI-1620

  • Country of origin:United States

  • Product Type: Analog input module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 20 x 130 x 190 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell FC-SAI-1620M is a conformal-coated, safe high-density analog input module engineered for high-integrity process safeguarding and critical automation applications within the Honeywell Safety Manager system platform. Operating on a 24 Vdc power supply, this module provides 16 dedicated analog input channels designed to interface with 0(4)–20 mA field transmitters and process instrumentation. It plays a key role in acquiring analog process variables and routing signal data over the internal Safety Manager IO Bus directly to the Quad Processor Pack (QPP) for high-integrity safety logic processing.

Designed to meet stringent functional safety standards up to SIL3 per IEC 61508, the FC-SAI-1620M executes continuous internal diagnostic self-tests within a defined Diagnostic Test Interval (DTI). Its conformal coating protects the internal Eurocard circuit board against harsh industrial environments, ensuring reliable long-term performance in Emergency Shutdown (ESD), Fire and Gas (F&G) detection, and Burner Management Systems (BMS).

Features

  • Conformal Coating: Formulated with protective coating (FC prefix) to resist environmental contaminants, moisture, and corrosive airborne elements in harsh plant environments.
  • High-Density Channel Layout: Features 16 safe analog input channels within a compact 3U / 4HP Eurocard form factor to maximize cabinet rack space.
  • SIL3 Functional Integrity: Fully certified for use in safety instrumented functions up to Safety Integrity Level 3 in both single and Quadruple Modular Redundant (QMR) architectures.
  • Comprehensive Self-Diagnostics: Conducts automatic, background diagnostic testing of internal circuitry and signal paths within the Diagnostic Test Interval (DTI) to detect and isolate hardware anomalies safely.
  • Field Termination Assembly Integration: Connects seamlessly to external Field Termination Assemblies (such as TSAI-1620m or TSHART-1620m) using standard System Interconnection Cables (FS-SIC-0001).
  • Hot-Swappable Subsystem Architecture: Integrates into the Safety Manager IO chassis backplane via standard 32-pin DIN 41612F connectors with key coding to prevent improper module insertion.

Applications

  • Process Safeguarding & ESD: Monitors critical process instrumentation (pressure, temperature, flow, level) for Emergency Shutdown loops.
  • Fire & Gas (F&G) Monitoring: Interfaces with analog gas and flame detectors in hydrocarbon processing and off-shore facilities.
  • Burner Management Systems (BMS): Safe tracking of fuel pressures, airflow, and flame intensity signals in boiler and furnace control applications.
  • Turbine & Compressor Protection: Continuous monitoring of operating variables to prevent surge, overpressure, or mechanical overspeed conditions.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model FC-SAI-1620M
Part Number Prefix FC (Conformal Coated)
System Platform Safety Manager
Module Type Safe High-Density Analog Input Module
Number of Channels 16 channels
Nominal Voltage 24 Vdc
Signal Range 0–20 mA / 4–20 mA
Safe Failure Fraction (SFF) ≥ 99%
Safety Integrity Level Up to SIL3 (IEC 61508 / ISA S84.01)
Module Form Factor Eurocard (100 x 160 mm / 3.94 x 6.30 in)
Panel Dimensions Height: 3U (3 HE), Width: 4HP (4 TE)
Connector Type 32-pin DIN 41612F connector
Operating Temperature -5 degC to 70 degC (14 degF to 158 degF) ambient
Storage Temperature -25 degC to 80 degC (-13 degF to 176 degF)
Relative Humidity 5% to 95%, non-condensing
Vibration Tolerance IEC 60068-2-6; 1 G at 57 Hz to 150 Hz; 0.075 mm from 10 Hz to 57 Hz
Shock Resistance IEC 60068-2-27; 15 G for 11 ms, 3 axes

Connections / Interfaces

Connection Point Description
Backplane Connector Standard 32-pin DIN 41612F Eurocard interface with mechanical keying
System Cable Interface Connects to Field Termination Assembly (TSAI-1620m / TSHART-1620m) via FS-SIC-0001 System Interconnection Cable
Primary Bus Link Communicates with the Control Processor via the Safety Manager horizontal and vertical IO Bus

Installation Guidelines

  1. Pre-Installation Inspection: Verify that the module model code (FC-SAI-1620M) matches project drawings and check the conformal coating for any physical damage prior to installation.
  2. Power Off Rack Section: Ensure supply power to the target slot or chassis segment is turned off or isolated according to plant safety procedures before inserting non-redundant hardware.
  3. Align and Seat Module: Carefully align the Eurocard edges with the card guides in the 3U slot of the IOCHAS chassis. Push firmly until the 32-pin DIN 41612F connector seats completely into the backplane.
  4. Secure Fasteners: Tighten top and bottom retaining screws on the front panel to guarantee proper grounding and mechanical stability under vibration.
  5. Cabling to FTA: Connect the System Interconnection Cable (FS-SIC-0001) from the rear backplane port to the corresponding Field Termination Assembly (TSAI-1620m or TSHART-1620m).

Configuration / Commissioning / Replacement

Configuration Guidelines

  • Define channel parameters and signal ranges (0–20 mA or 4–20 mA) in the Safety Builder software environment using Point Configurator.
  • Configure channel-specific fault reaction states (e.g., Top Scale, Bottom Scale, Scan, or Hold) according to loop safety requirements.

Commissioning Recommendations

  • Perform field signal loop checks from the transmitter through the FTA to the Safety Builder station to verify live reading accuracy.
  • Validate diagnostic trip thresholds and verify that input discrepancies trigger appropriate alarms on the station HMI without tripping operational process loops prematurely.

Replacement Recommendations

  • Parameter Backup: Confirm the project logic and I/O map database are fully backed up in Safety Builder prior to replacing an existing module.
  • Hardware Matching: Ensure the replacement module carries the conformal-coated FC-SAI-1620M designation to maintain environmental resistance ratings in critical areas.

Compliance and Certifications

  • Functional Safety: Certified by TÜV to IEC 61508 Parts 1–7 (SIL3 capable) and ANSI/ISA S84.01.
  • Standard ESD/ESD: Compliant with DIN V VDE 19250, DIN V VDE 0801, and UL 1998 / UL 508.
  • Hazardous Locations: CSA certified (C22.2 No. 142-M1987) and FM 3611 Class I, Division 2 compliant.
  • CE Compliance: Conforms to European Directives 89/336/EEC (EMC) and 73/23/EEC (Low Voltage Directive).
  • EMC Immunity: Tested to IEC 61000-4-2 (ESD Level 4), IEC 61000-4-3 (Radiated), IEC 61000-4-4 (Burst Level 3), and IEC 61000-4-5 (Surge Level 3).
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FC-SAI-1620M Safe High-Density Analog Input Module

What is the primary function of the Honeywell FC-SAI-1620M analog input module?

The Honeywell FC-SAI-1620M is a high-density, 16-channel safe analog input module designed to interface 0(4)–20 mA field signals with the Honeywell Safety Manager system for SIL3 safety-critical control and process safeguarding applications.

What does the 'FC' prefix indicate in the Honeywell FC-SAI-1620M model number?

The 'FC' prefix designates that the Honeywell FC-SAI-1620M module features conformal coating on its electronic assemblies, providing enhanced resistance against humidity, moisture, and corrosive atmospheric contaminants compared to non-coated 'FS' models.

Which Field Termination Assemblies (FTAs) are compatible with the Honeywell FC-SAI-1620M?

The Honeywell FC-SAI-1620M connects to field wiring via dedicated Field Termination Assemblies, such as the TSAI-1620m for standard 0(4)–20 mA signals or the TSHART-1620m for HART-pass-through applications, using system interconnection cables.

What happens if a channel fault is detected on the Honeywell FC-SAI-1620M?

When an internal or signal path fault is detected during continuous self-testing, the Honeywell FC-SAI-1620M isolates the affected signal and sets the channel to its user-configured fault reaction state, such as Top Scale, Bottom Scale, Scan, or Hold.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...