Description

The Honeywell TK-IOLI01 (Part Number: 51403427-275) is a conformal-coated, double-wide I/O Link Module (IOLIM) designed for the Experion system architecture. It serves as a specialized communications interface gateway enabling C200E/C200 control processors to integrate seamlessly with Process Manager I/O (PMIO) structures. Occupying two slots in a Chassis Input/Output Module Series A (CIOM-A) chassis, the module translates data and communication protocols between the Series A backplane and downstream PMIO subsystems.

As part of the Experion Series A platform, the TK-IOLI01 features OEM conformal coating, providing enhanced protection against corrosive industrial environments classified as Moderate (G2) or Harsh (G3) per ANSI/ISA-S71.04-1985 standards. It allows process plants to modernize their control network using C200E processors while retaining existing PMIO hardware investments.

Features

  • PMIO Integration Interface: Acts as a direct gateway bridging Experion Series A chassis-based controllers to legacy Process Manager I/O networks.
  • Conformal Coating Protection: Factory-applied conformal coating (TK series) guards internal electronics against atmospheric contaminants and airborne corrosion.
  • Double-Wide Form Factor: Utilizes two physical slot positions in any standard 4, 7, 10, 13, or 17-slot Series A chassis.
  • Chassis Backplane Powered: Draws operating DC power directly from the Series A backplane power supply system.
  • Process Network Compatibility: Connects directly into Experion control architectures alongside C200E controllers and optional ControlNet interfaces.

Applications

  • PMIO Migration Projects: Interfacing C200E control processors with legacy PMIO hardware during DCS upgrades.
  • Hybrid DCS System Architectures: Bridging chassis-based Series A I/O sub-networks with field-proven PMIO installations.
  • Harsh Industrial Environments: Deployment in corrosive process plant environments requiring ANSI/ISA-S71.04-1985 G2/G3 class protection.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model TK-IOLI01
Part Number 51403427-275
Product Type I/O Link Module (IOLIM)
System Platform Experion Series A / CIOM-A
Supported Control Processor C200 / C200E Control Processor
Target Interface PMIO (Process Manager I/O)
Chassis Slot Requirement 2 Slots (Double-wide form factor)
Conformal Coating Yes (TK Series - G2/G3 Airborne Contaminants Rating)
Operating Temperature 0 to 60 degC (32 to 140 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5 to 95% noncondensing (derated to 55% above 40 degC)
Vibration (Operating) 10 to 60 Hz, 0.5 g max acceleration, 0.1 inches displacement
Mechanical Shock (Operating) 5 g max acceleration, 30 ms max duration
Altitude -300 to +3000 m

Installation Guidelines

  1. Pre-Installation Inspection: Verify the physical condition of the module, module slot keys, and backplane connectors. Confirm the part number matches 51403427-275.
  2. Power Off Procedure: Ensure chassis power is switched off before inserting or removing the double-wide module in hazardous or Class I, Div 2 locations.
  3. Slot Allocation: Select two adjacent free slots in the Series A chassis (e.g., 4, 7, 10, 13, or 17-slot chassis).
  4. Mounting: Align the card guides of the double-wide module with the chassis slots and press firmly until the module is fully seated in the backplane. Secure any top/bottom retaining latches.
  5. Interface Cable Connection: Connect the designated PMIO I/O Link communication cable to the front interface connector.
  6. System Power-Up: Apply backplane power and verify diagnostic LEDs to confirm proper boot sequence and bus communication status.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell TK-IOLI01 module?
The Honeywell TK-IOLI01 is an I/O Link Module (IOLIM) that acts as an interface gateway, enabling Experion C200 or C200E control processors to communicate directly with Process Manager I/O (PMIO) hardware structures.
How many chassis slots does the Honeywell TK-IOLI01 require?
The Honeywell TK-IOLI01 features a double-wide form factor and occupies two physical slot positions when installed in an Experion Series A chassis.
What is the difference between Honeywell TK and TC model prefixes?
Honeywell modules beginning with the TK prefix, such as the TK-IOLI01, include factory-applied conformal coating for corrosion protection in harsh environments. Modules with the TC prefix are uncoated.
Is the Honeywell TK-IOLI01 hot-swappable in hazardous locations?
Removal and insertion under power (RIUP) of the Honeywell TK-IOLI01 is permitted in ordinary, non-hazardous locations. However, RIUP is strictly prohibited when installed in Class I, Division 2 hazardous locations.
Reviews

TK-IOLI01 51403427-275

Stock & lead time on request

Call
1 of 3

Honeywell TK-IOLI01 51403427-275 Series A I/O Link Module

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TK-IOLI01 51403427-275

  • Country of origin:United States

  • Product Type: I/O Link Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 850g

  • Dimensions: 145 x 169 x 70 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell TK-IOLI01 (Part Number: 51403427-275) is a conformal-coated, double-wide I/O Link Module (IOLIM) designed for the Experion system architecture. It serves as a specialized communications interface gateway enabling C200E/C200 control processors to integrate seamlessly with Process Manager I/O (PMIO) structures. Occupying two slots in a Chassis Input/Output Module Series A (CIOM-A) chassis, the module translates data and communication protocols between the Series A backplane and downstream PMIO subsystems.

As part of the Experion Series A platform, the TK-IOLI01 features OEM conformal coating, providing enhanced protection against corrosive industrial environments classified as Moderate (G2) or Harsh (G3) per ANSI/ISA-S71.04-1985 standards. It allows process plants to modernize their control network using C200E processors while retaining existing PMIO hardware investments.

Features

  • PMIO Integration Interface: Acts as a direct gateway bridging Experion Series A chassis-based controllers to legacy Process Manager I/O networks.
  • Conformal Coating Protection: Factory-applied conformal coating (TK series) guards internal electronics against atmospheric contaminants and airborne corrosion.
  • Double-Wide Form Factor: Utilizes two physical slot positions in any standard 4, 7, 10, 13, or 17-slot Series A chassis.
  • Chassis Backplane Powered: Draws operating DC power directly from the Series A backplane power supply system.
  • Process Network Compatibility: Connects directly into Experion control architectures alongside C200E controllers and optional ControlNet interfaces.

Applications

  • PMIO Migration Projects: Interfacing C200E control processors with legacy PMIO hardware during DCS upgrades.
  • Hybrid DCS System Architectures: Bridging chassis-based Series A I/O sub-networks with field-proven PMIO installations.
  • Harsh Industrial Environments: Deployment in corrosive process plant environments requiring ANSI/ISA-S71.04-1985 G2/G3 class protection.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model TK-IOLI01
Part Number 51403427-275
Product Type I/O Link Module (IOLIM)
System Platform Experion Series A / CIOM-A
Supported Control Processor C200 / C200E Control Processor
Target Interface PMIO (Process Manager I/O)
Chassis Slot Requirement 2 Slots (Double-wide form factor)
Conformal Coating Yes (TK Series - G2/G3 Airborne Contaminants Rating)
Operating Temperature 0 to 60 degC (32 to 140 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5 to 95% noncondensing (derated to 55% above 40 degC)
Vibration (Operating) 10 to 60 Hz, 0.5 g max acceleration, 0.1 inches displacement
Mechanical Shock (Operating) 5 g max acceleration, 30 ms max duration
Altitude -300 to +3000 m

Installation Guidelines

  1. Pre-Installation Inspection: Verify the physical condition of the module, module slot keys, and backplane connectors. Confirm the part number matches 51403427-275.
  2. Power Off Procedure: Ensure chassis power is switched off before inserting or removing the double-wide module in hazardous or Class I, Div 2 locations.
  3. Slot Allocation: Select two adjacent free slots in the Series A chassis (e.g., 4, 7, 10, 13, or 17-slot chassis).
  4. Mounting: Align the card guides of the double-wide module with the chassis slots and press firmly until the module is fully seated in the backplane. Secure any top/bottom retaining latches.
  5. Interface Cable Connection: Connect the designated PMIO I/O Link communication cable to the front interface connector.
  6. System Power-Up: Apply backplane power and verify diagnostic LEDs to confirm proper boot sequence and bus communication status.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell TK-IOLI01 51403427-275 Series A I/O Link Module

What is the primary function of the Honeywell TK-IOLI01 module?

The Honeywell TK-IOLI01 is an I/O Link Module (IOLIM) that acts as an interface gateway, enabling Experion C200 or C200E control processors to communicate directly with Process Manager I/O (PMIO) hardware structures.

How many chassis slots does the Honeywell TK-IOLI01 require?

The Honeywell TK-IOLI01 features a double-wide form factor and occupies two physical slot positions when installed in an Experion Series A chassis.

What is the difference between Honeywell TK and TC model prefixes?

Honeywell modules beginning with the TK prefix, such as the TK-IOLI01, include factory-applied conformal coating for corrosion protection in harsh environments. Modules with the TC prefix are uncoated.

Is the Honeywell TK-IOLI01 hot-swappable in hazardous locations?

Removal and insertion under power (RIUP) of the Honeywell TK-IOLI01 is permitted in ordinary, non-hazardous locations. However, RIUP is strictly prohibited when installed in Class I, Division 2 hazardous locations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...