Light-On and Dark-On Photoelectric Sensor Logic
Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.
Manufacturer: Lenze
Product No.: E84AVSCE7514SX0
Country of origin:Germany
Product Type: Variable Frequency Drives
Barcode: 85044095
Payment: T/T, Western Union
Weight: 1200g
Dimensions: 180 x 140 x 80 mm
Shipping port: Xiamen
Warranty: 12 months
Providing precise speed and torque control for three-phase asynchronous motors, the Lenze E84AVSCE7514SX0 is an industrial frequency inverter designed for space-saving control cabinet installation. Operating on a 3-phase 400/500 V AC mains supply, this 0.75 kW (1.0 HP) rated unit belongs to the highly reliable 8400 StateLine series. It features integrated interference suppression measures to ensure electromagnetic compatibility (EMC) in demanding industrial environments, minimizing electrical noise without requiring external filter modules in standard configurations.
| Parameter | Value |
|---|---|
| Manufacturer | Lenze |
| Model Code | E84AVSCE7514SX0 |
| Series | 8400 StateLine |
| Mains Voltage | 3 AC 400 V / 500 V (50/60 Hz) |
| Rated Power | 0.75 kW (1.0 HP) |
| Enclosure Rating | IP20 |
| Communication Interface | CANopen (onboard) |
| Country of Origin | Germany |
| Product Weight | 1.20 kg |
| Dimensions (H x W x D) | 180 x 140 x 80 mm |
| Commodity Code | 85044095 |
The E84AVSCE7514SX0 belongs to the 8400 StateLine family. It can directly replace older 8200 vector series drives of equivalent power ratings, though physical mounting footprints and control terminal layouts differ. Ensure that any existing CANopen configuration files (.EDS) are updated in your PLC master (such as a Siemens S7 or Lenze Controller) to reflect the 8400 StateLine profile.
When operating at the upper limit of 500 V AC, thermal dissipation increases slightly. Maintain a minimum clearance of 100 mm above and below the unit inside the enclosure to prevent localized overheating. Avoid running the drive continuously below 10 Hz without an external forced-cooling fan on the motor, as standard self-ventilated motors will overheat at low speeds under constant torque loads.
Use shielded motor cables with a low-impedance 360-degree shield connection at both the drive's PE bracket and the motor terminal box. Commissioning is best performed using the Lenze L-force Engineer software via an optional USB diagnostic adapter (E84DGCDXM). Ensure the termination resistor (120 Ohm) is switched on at the physical ends of the CANopen network segment.
Global Express Shipping
Returns & Warranty

Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Germany
|