Description

Designed for power quality optimization in industrial drive systems, the Lenze ELN3-0120H017 three-phase mains choke reduces mains harmonics and limits commutation spikes. This line reactor acts as an inductive impedance in the mains supply line, protecting upstream frequency inverters and sensitive electronic components from transient overvoltages and grid disturbances. By smoothing the current waveform, the ELN3-0120H017 significantly reduces the RMS value of the mains current, lowering thermal load on cables and distribution equipment while improving the overall power factor of the system.

Features

  • Reduces harmonic distortion (THDi) in compliance with international power quality standards.
  • Limits mains current peaks and voltage spikes to protect inverter input rectifiers.
  • Optimized for integration with Lenze frequency inverters and drive controllers.
  • Three-phase design engineered for continuous industrial operation.
  • Compact footprint allows for space-saving mounting inside control cabinets.

Applications

  • Frequency inverter mains buffering in automated production lines.
  • Industrial motor control centers and machine tool manufacturing.
  • Pumping, ventilation, and air conditioning (HVAC) systems.
  • Power quality improvement in weak or unstable electrical grids.

Technical Specifications

Manufacturer Lenze
Part Number/Model ELN3-0120H017
Series ELN3
Product Type Mains Choke / Line Reactor
Number of Phases 3-phase
Rated Current 17 A
Nominal Inductance 1.2 mH
Nominal Voltage Range Up to 480 V AC
Mains Frequency 50 / 60 Hz
Country of Origin Germany

Connections and Interfaces

Terminal Designation Function
1U1 / 1V1 / 1W1 Mains Input Connection (L1, L2, L3)
1U2 / 1V2 / 1W2 Load Output Connection to Inverter (U, V, W)
PE Protective Earth Connection

Installation Guidelines

  • Mounting Position: Mount vertically on a flat, thermally conductive surface to ensure optimal natural convection and heat dissipation.
  • Clearance: Maintain a minimum clearance of 50 mm above and below the unit to prevent thermal blockages.
  • Grounding: Ensure a low-impedance PE connection directly to the control cabinet mounting plate.
  • Cable Routing: Route input mains cables and output cables to the inverter separately to minimize electromagnetic interference (EMI).

Compliance and Certifications

  • CE
  • RoHS Compliant

FAQ

What is the primary function of the Lenze ELN3-0120H017?

The Lenze ELN3-0120H017 is a three-phase mains choke designed to reduce harmonic distortion, limit mains current peaks, and protect frequency inverters from voltage transients.

What are the electrical ratings for this line reactor?

It is rated for a nominal current of 17 A and has a nominal inductance of 1.2 mH for three-phase AC networks up to 480 V.

How should the ELN3-0120H017 be mounted?

It should be mounted vertically on a flat surface inside a control cabinet, leaving at least 50 mm of clearance above and below for proper heat dissipation.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.