Mitsubishi Electric

Mitsubishi Electric FX3GE-40MR/ES FX3GE Series Programmable Controller

SKU FX3GE-40MR/ES

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX3GE-40MR/ES

  • Country of origin:United States

  • Product Type: Programmable Logic Controllers

  • Payment: T/T, Western Union

  • Weight: 800g

  • Dimensions: 175 mm x 90 mm x 86 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed to meet the demands of compact yet comprehensive industrial automation systems, the FX3GE-40MR/ES main unit integrates advanced control capabilities with built-in network connectivity and analog processing. This programmable logic controller (PLC) from the Mitsubishi Electric MELSEC FX family offers 40 local I/O points in a single, space-saving chassis.

The unit features a robust relay output structure alongside 24 discrete digital inputs, operating on a standard wide-range AC power supply. Engineered for standalone machinery and distributed control systems, the FX3GE-40MR/ES includes a built-in Ethernet port and integrated analog functional channels. This eliminates the need for external analog or network adapters in standard applications, optimizing both cabinet footprint and system integration costs.

Features

  • High-density local configuration with 24 integrated digital inputs and 16 electromagnetic relay outputs.
  • Built-in Ethernet port for seamless network integration, programming, data monitoring, and SCADA connectivity.
  • Integrated analog capability featuring 2 analog inputs and 1 analog output channel natively on the CPU board.
  • Wide-range power supply compatibility, operating efficiently on standard 100-240 VAC networks.
  • High-speed program execution processing to handle demanding sequence control and timing tasks.
  • Expandable hardware platform supporting additional MELSEC FX series expansion boards and special function blocks.

Applications

  • Packaging, labeling, and wrapping machinery.
  • Water and wastewater treatment pumping systems.
  • HVAC, environmental, and climate control automation.
  • Material handling systems, conveyors, and sorting lines.
  • Food and beverage manufacturing and process control.

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number / Model FX3GE-40MR/ES
Series MELSEC FX3GE Series
Controller Type Programmable Logic Controller (PLC) Main Unit
Power Supply Rating 100 to 240 VAC (+10% / -15%), 50/60 Hz
Total Integrated I/O Points 40
Digital Inputs 24 points (Sink/Source 24 VDC)
Digital Outputs 16 points (Relay type)
Built-in Analog Inputs 2 channels (0 to 10 VDC or 4 to 20 mA)
Built-in Analog Outputs 1 channel (0 to 10 VDC or 4 to 20 mA)
Communication Ports 1x RJ45 (Ethernet), 1x Mini-USB, 1x RS-422
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 75 degC
Dimensions (W x H x D) 175 mm x 90 mm x 86 mm
Weight 0.8 kg

Installation Guidelines

  • Mount the unit on standard 35 mm DIN rail or directly to a backpanel using the integrated mounting screw holes.
  • Provide a minimum clearance of 50 mm above and below the PLC to maintain proper natural convection cooling.
  • Ensure class-D grounding (grounding resistance of 100 ohms or less) using a dedicated grounding wire with a minimum cross-section of 2 mm squared.
  • Route low-voltage signal lines (Ethernet, analog, and digital I/O) separately from high-voltage AC power wiring to prevent electromagnetic noise coupling.

Compliance and Certifications

  • CE Mark
  • UL Listed
  • cUL Listed
  • KC (Korean Certification)

FAQ

What communication interfaces are built into the FX3GE-40MR/ES?

The FX3GE-40MR/ES features an integrated Ethernet (RJ45) port, a USB mini-B programming port, and a standard RS-422 port for versatile connectivity options.

What are the technical specifications of the integrated analog channels?

The unit features 2 analog input channels and 1 analog output channel. These channels can be configured to operate with either 0 to 10 VDC voltage signals or 4 to 20 mA current signals.

Does this model support both sink and source input wiring?

Yes, the 24 digital inputs on the FX3GE-40MR/ES support both sink and source wiring configurations depending on how the common terminal is connected.

Can the physical I/O on the FX3GE-40MR/ES be expanded?

Yes, the FX3GE series allows expansion through MELSEC FX series extension blocks, adapter boards, and special function blocks to increase system capacity.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.