Mitsubishi Electric

Mitsubishi Electric MR-JE-200A MR-JE Series Servo Amplifier

SKU MR-JE-200A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: MR-JE-200A

  • Country of origin:United States

  • Product Type: Servo Amplifiers

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Designed for high-precision motion control, the Mitsubishi Electric MR-JE-200A regulates motor velocity and torque within demanding industrial automation architectures. This MR-JE Series servo amplifier delivers reliable dynamic response and features a robust power stage capable of driving compatible rotary servo motors.

Key Features

  • Sine-wave PWM control with advanced current control loop.
  • Integrated dynamic brake for rapid deceleration and safety shutdown.
  • Forced cooling design to maintain optimal thermal performance.
  • IP20 open-type protective structure.

Applications

  • Packaging machinery and continuous material handling.
  • Multi-axis positioning tables and pick-and-place systems.
  • Textile manufacturing and processing equipment.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model MR-JE-200A
Series MR-JE-_A
Output Rated Current 11.0 A
Power Supply Input Voltage 3-phase or 1-phase 170 V AC to 264 V AC
Control Method Sine-wave PWM control, current control method
Dynamic Brake Built-in
Cooling Method Force cooling
IP Rating IP20 (Open)
Net Weight 2.1 kg
Shipping Weight 4.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The MR-JE-200A is designed for compatibility with specific HF-KN and HF-JN series servo motors. Ensure firmware compatibility when replacing older MR-JE units, as parameter structures may vary.

Application Pitfalls & Engineering Notes

When operating on a single-phase supply, derating may apply. Ensure adequate clearance around the force-cooling fan intake and exhaust paths to prevent thermal tripping under high-duty cycle operations.

Commissioning & Wiring Tips

Use twisted-shielded pair cables for control signals to minimize electromagnetic interference. Ensure the built-in dynamic brake parameters are correctly configured in the setup software to match the load inertia.

Installation Guidelines

CRITICAL WARNING Ensure all input power sources (both main circuit and control circuit) are completely de-energized and locked out before attempting installation or wiring. Wait at least 15 minutes after power-off for the charge lamp to turn off and residual bus voltage to discharge to safe levels.
1
Mount the amplifier vertically on a flat, conductive metal plate to ensure proper grounding and heat dissipation.
2
Connect the main power supply lines to the L1, L2, and L3 terminals (or L1 and L2 for single-phase operation) using specified wire gauges.
3
Wire the servo motor power outputs (U, V, W) and connect the encoder feedback cable to the CN2 connector.
4
Establish ground connections securely to the protective earth (PE) terminal.

FAQ

Can the MR-JE-200A be operated on a single-phase power supply?

Yes, it supports both 3-phase and 1-phase input voltages from 170 V AC to 264 V AC, though single-phase operation may require derating depending on the load.

What cooling method does this servo amplifier utilize?

It uses an integrated force-cooling fan system to manage thermal dissipation during high-duty cycles.

Does this model include an integrated dynamic brake?

Yes, the unit features a built-in dynamic brake for rapid deceleration and emergency stopping.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.