Omron

NX-AD2603 | Omron | Analog Input Unit

SKU NX-AD2603

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: NX-AD2603

  • Country of origin:Japan

  • Product Type: Analog Input Unit

  • Payment: T/T, Western Union

  • Weight: 70g

  • Shipping port: Xiamen

  • Warranty: 12 months

The NX-AD2603 is a high-precision Analog Input Unit from Omron’s NX-series, designed for high-speed, reliable data acquisition in industrial control systems. This module features 2 input points utilizing single-ended input technology, capable of processing voltage signals within the -10 to +10 V range. With a resolution of 1/8000 and a conversion range extending from -5% to 105% of the full scale, it provides accurate signal monitoring for a wide variety of industrial transducers and sensors. The module utilizes Free-Run refreshing to ensure consistent data updates, making it an ideal choice for stable process control and monitoring applications within the modular Omron NX-series I/O ecosystem.

Features

  • 2 analog input points with single-ended configuration
  • High-resolution signal processing (1/8000)
  • Voltage input range: -10 to +10 V
  • Extended conversion range (-5 to 105% of full scale)
  • Free-Run refreshing method for continuous data acquisition
  • Lightweight, compact design (0.070 kg) for space-efficient cabinet integration
  • Robust absolute maximum rating of ±15 V

Applications

  • Analog sensor signal monitoring (pressure, flow, temperature)
  • Process control loop integration
  • High-speed data logging in automated machinery
  • Modular I/O expansion for NX-series PLC systems

Technical Specifications

Feature Specification
Manufacturer Omron
Part Number NX-AD2603
Product Type Analog Input Unit
Number of Points 2
I/O Refreshing Free-Run refreshing
Input Method Single-ended input
Input Range -10 to +10 V
Input Conversion Range -5 to 105% (full scale)
Absolute Maximum Rating ±15 V
Resolution 1/8000
Weight 0.070 kg
Shipping Weight 1 kg

Installation Guidelines

  • Mounting: Snap the NX-AD2603 onto the NX-series I/O bus coupler or adjacent I/O units on a 35 mm DIN rail. Ensure the side connector is fully engaged to establish the internal bus communication.
  • Wiring: Connect your analog sensors to the terminal block. Given the single-ended input method, ensure that the signal and the reference ground are properly connected to prevent ground loop noise.
  • Input Protection: Although the module is rated for an absolute maximum of ±15 V, always use signal conditioners or surge protection if the field environment is subject to high-voltage spikes.
  • Configuration: Use the Omron Sysmac Studio software to configure the scaling and filtering parameters of the input points to match your specific field sensor requirements.

FAQ

What does 'Free-Run refreshing' mean for this unit?

Free-Run refreshing allows the analog input unit to process and update data points independently of the PLC's task execution cycle, providing continuous and consistent signal monitoring.

What is the resolution of the NX-AD2603?

The module offers a resolution of 1/8000 of the full-scale input range, ensuring high precision for analog signal conversion.

What is the input method for this module?

The unit uses a single-ended input method, where each signal is measured relative to a common reference ground.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Japan

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.