Omron

Omron E5CC-RX2ASM-006 Digital Temperature Controller

SKU E5CC-RX2ASM-006

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: E5CC-RX2ASM-006

  • Country of origin:Japan

  • Product Type: Digital Temperature Controllers

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The E5CC-RX2ASM-006 is a versatile digital temperature controller from Omron’s compact E5CC series. Featuring a standard 48 x 48 mm (1/16 DIN) front panel size, it is designed for space-constrained industrial control cabinets. This unit provides high-precision temperature regulation and is highly configurable, making it suitable for a wide range of thermal management applications.

This specific model comes equipped with a relay control output, two auxiliary outputs for alarm or status signaling, and supports universal inputs (thermocouples, RTDs, etc.). The "006" suffix indicates that this model includes advanced features such as two event inputs for external triggering and a transfer output for data monitoring or retransmission. It operates on a universal 100 to 240 VAC power supply and utilizes traditional screw terminals for secure, reliable field wiring.

Features

  • Compact Design: 48 x 48 mm panel size
  • Control Output: Relay output
  • Auxiliary Outputs: 2 integrated auxiliary outputs
  • Input Versatility: Supports universal input types (thermocouple, RTD)
  • Advanced Features: Includes 2 event inputs and a transfer output
  • Voltage Supply: 100 to 240 VAC
  • Terminals: Secure screw terminals

Applications

  • Plastic injection molding machines
  • Industrial ovens and furnaces
  • Food processing equipment (sealing and heating)
  • Packaging machinery
  • Environmental chambers and laboratory heating systems

Technical Specifications

Feature Specification
Manufacturer Omron
Model E5CC-RX2ASM-006
Size 48 x 48 mm
Control Output 1 Relay
Auxiliary Outputs 2
Input Type Universal
Power Supply 100 to 240 VAC
Terminal Type Screw Terminals
Options Event Inputs (2), Transfer Output
Shipping Weight 2.0 kg

Installation Guidelines

  • Mounting: Ensure the controller is mounted in a panel cutout with sufficient clearance for the mounting adapter.
  • Wiring: Verify the input sensor type (e.g., K-type thermocouple) matches the configuration settings in the controller's software menu to prevent measurement errors.
  • Grounding: Keep sensor wiring away from power lines to reduce electrical noise, which can cause erratic temperature readings.
  • Configuration: Use the CX-Thermo support software or the front panel interface to set the PID parameters correctly for the specific thermal mass of your process.

FAQ

What does the 'Universal input' feature allow for?

It allows the controller to accept various sensor types, such as thermocouples or RTDs, without needing specialized hardware for each type.

What is the purpose of the transfer output included in the '006' model?

The transfer output allows you to send the current temperature or setpoint value to another device, such as a PLC or a data recorder, for monitoring or logging purposes.

Does this model support remote triggering?

Yes, it includes 2 event inputs that can be used to trigger specific controller actions from an external source.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Japan

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.