Managing precise thermal profiles in demanding processing environments is the primary function of the Omron E5CC-RX0ASM-000 digital temperature controller. Operating with an ultra-fast 50 ms input sampling period, this instrument executes real-time control loop adjustments to stabilize dynamic systems. It features a high-contrast dual display for clear visibility of Process Value (PV) and Set Value (SV) parameters, making it an essential component for critical industrial machinery. Designed with a shallow housing depth to minimize panel space requirements, this unit handles universal thermal inputs with high accuracy, ensuring reliable operational repeatability.

Key Features

  • High-Speed Sampling: Rapid 50 ms sampling cycle captures micro-thermal deviations instantly.
  • Universal Input Compatibility: Direct integration with thermocouples, platinum resistance thermometers, and standard analog linear signals.
  • Compact Housing Profile: Panel-mount configuration requires minimal enclosure depth, maximizing internal wiring space.
  • Multi-Status Display: Clear digital readouts provide real-time diagnostic and process feedback directly on the front interface.

Applications

  • Packaging machinery sealing-jaw thermal regulation.
  • Plastics extrusion and injection molding barrel zone controls.
  • Industrial heat-treatment chambers and laboratory ovens.
  • Food pasteurization and high-accuracy liquid processing operations.

Technical Specifications

Manufacturer Omron
Model / SKU E5CC-RX0ASM-000
Product Series E5CC Series
Product Type Digital Temperature Controller
Input Sampling Period 50 ms
Thermocouple Accuracy (plus/minus 0.3% of PV or plus/minus 1 degC, whichever is greater) plus/minus 1 digit max.
RTD Input Accuracy (plus/minus 0.2% of PV or plus/minus 0.8 degC, whichever is greater) plus/minus 1 digit
Analog Input Accuracy plus/minus 0.2% FS plus/minus 1 digit max.
Current Transformer (CT) Input Accuracy plus/minus 5% FS plus/minus 1 digit max.
Transfer Output Accuracy plus/minus 0.3% FS max
Remote SP Input Accuracy plus/minus 0.2% FS plus/minus 1 digit max
Net Weight 0.13 kg
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

When replacing older legacy controllers such as the Omron E5CN series, verify depth clearances. The E5CC series features a shallow 60 mm body behind the panel, which is significantly smaller than previous configurations. Program parameters can be migrated seamlessly via CX-Thermo software, eliminating the need for manual code translation.

Application Pitfalls & Engineering Notes

Because of the rapid 50 ms sampling rate, high-gain PID configurations may exhibit oscillations if there is physical thermal lag between the heating element and the sensor probe. Running the auto-tuning sequence at normal system operating temperatures rather than cold-starting the process minimizes integral windup risk.

Commissioning & Wiring Tips

Thermocouple extension wires must be routed completely isolated from high-voltage AC lines to avoid electromagnetic interference. Ensure that rear terminal connection screws are torqued exactly to manufacturer specifications to maintain solid contact points, as loose connections will induce cold-junction compensation measurement errors.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate and lock out all electrical power sources supplying the control cabinet prior to beginning hardware installation. Ensure the system has fully discharged any capacitive voltage to prevent electrical shock. Verify physical layout dimensions and panel cutouts prior to securing the controller brackets.

1
Insert the controller housing through the standard DIN panel cutout from the front face.
2
Slide the mounting fixture along the housing body from the rear of the panel until it locks tightly against the panel inner wall.
3
Terminate field power and sensor wiring to the rear terminals using insulated crimp terminals, ensuring clean wire separation.

FAQ

What is the sampling rate of the E5CC-RX0ASM-000?

The unit features a high-speed input sampling period of 50 ms, enabling rapid feedback loops and stable process temperature regulation.

What sensor inputs does this Omron temperature controller accept?

This controller supports universal inputs including standard thermocouples, platinum resistance thermometers (RTDs), and analog linear signals.

How can I avoid cold-junction measurement errors during installation?

Keep all thermocouple sensor wiring physically separated from high-current power cables, and torque the terminal screws precisely to prevent thermal drift.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.