Designing Power and Communication Redundancy
Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.
Manufacturer: Omron
Product No.: E5AN-HTAA2HBM-500 AC100-240
Country of origin:Japan
Product Type: Temperature Controllers
Payment: T/T, Western Union
Weight: 310g
Shipping port: Xiamen
Warranty: 12 months
Engineered for high-precision thermal profiling in complex processes, the Omron E5AN-HTAA2HBM-500 AC100-240 provides advanced ramp/soak program control and comprehensive system diagnostics. This 1/4 DIN panel-mount controller features a high-speed sampling rate of 60 milliseconds and universal sensor inputs, enabling highly responsive and accurate control loop performance. Outfitted with advanced event inputs and heater burnout detection, this unit ensures rapid fault isolation in automated industrial heating systems.
| Manufacturer | Omron |
| Model Code | E5AN-HTAA2HBM-500 AC100-240 |
| Control Type | Program Type (Ramp/Soak) / Single Setpoint (Selectable) |
| Supply Voltage | 100 to 240 VAC, 50/60 Hz |
| Power Consumption | 10 VA maximum |
| Bezel Dimensions | 96 x 96 mm (1/4 DIN) |
| Panel Depth | 78 mm |
| Control Output | Relay (SPST-NO, 250 VAC, 3 A resistive load) |
| Heater Burnout Entrances | 2 channels (supports E54-CT1 and E54-CT3 sensors) |
| Auxiliary Outputs | 3 auxiliary relay outputs |
| Event Inputs | Yes (M-type expansion card functionality included) |
| Operating Temperature | -10 to +55 degC (no icing or condensation) |
| Net Weight | 0.31 kg |
| Shipping Weight (Calculated) | 1.5 kg (with standard structural protective packaging) |
| Terminal Number | Signal / Function Assignment |
|---|---|
| 1 & 2 | Power Supply Inputs (100 to 240 VAC, neutral/line) |
| 11 & 12 | Control Output 1 (Relay output, normally open) |
| 25 & 26 | Heater Burnout / CT1 & CT2 Sensor Inputs |
| 31, 32, 33 | Universal Temperature Sensor Inputs (Thermocouple / RTD / Analog Input) |
Alternative Models & Compatibility: The "HT" designation denotes a program-capable controller. When swapping with standard "H" models (such as E5AN-HAA2HBM), verify that program ramp/soak profiles are deactivated or convert them back to a static setpoint. Ensure the auxiliary output assignments match exactly, as the E5AN-H series features dedicated mapping configurations.
Application Pitfalls & Engineering Notes: When utilising the Heater Burnout (HB) detection function, set the control output cycle time to at least 1 second when using a solid-state relay. Rapid switching below 1 second can result in false heater burnout alarms because the controller's internal CT measurement routine requires a minimum duration of current flow to evaluate the load current.
Commissioning & Wiring Tips: In high-noise electrical panels containing high-power AC drives, run the temperature sensor input lines using twisted-shielded pair cables. Earth the shield at the control panel chassis ground plate only. For long RTD sensor lines, configure the input filter time constant parameter (INF) to minimize process variable fluctuations.
Global Express Shipping
Returns & Warranty

Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Japan
|