Description

The Omron E5CN-HQ2M-500-AC100-240 is a high-performance, high-resolution temperature controller designed for precision industrial process monitoring. Utilizing the advanced architecture of the E5CN-H series, this 1/16 DIN device delivers exceptionally fast processing and high input accuracy. It features universal inputs that allow seamless connection to various sensor types, including thermocouples, platinum resistance thermometers, and analog current/voltage transmitters, minimizing spare parts inventory. With integrated logic operations and predictive maintenance counters, this unit optimizes system reliability and control loop performance in demanding thermal applications.

Features

  • High-Speed Sampling: Incorporates a fast 60 ms control sampling cycle for rapid response to dynamic process variations.
  • Universal Inputs: Multi-input capability supports thermocouples, Pt100/JPt100 sensors, and analog voltage/current inputs on a single hardware platform.
  • High-Resolution Display: Features a high-visibility, 5-digit screen capable of showing temperatures down to 0.01 degC.
  • Status Indicator: Advanced PV/SV status display alternates between PV/SV status and operational flags such as RUN/STOP, auto/manual, and alarms.
  • Logic Operations: Supports custom logic (AND, OR, and delay configurations) using the CX-Thermo software (Version 4.0 or higher).
  • Preventive Maintenance: Equipped with an integrated ON/OFF counter for control outputs to monitor relay wear and schedule upkeep before failures occur.

Applications

  • Plastic extrusion and injection molding machinery.
  • Packaging equipment and heat-sealing systems.
  • Food and beverage thermal processing lines.
  • Semiconductor manufacturing and environmental test chambers.
  • Industrial ovens, furnaces, and ceramic kilns.

Technical Specifications

  • Weight
  • Manufacturer Omron
    Model / Part Number E5CN-HQ2M-500-AC100-240
    Series E5CN-H
    Form Factor 1/16 DIN (48 x 48 mm)
    Power Supply Voltage 100 to 240 VAC, 50/60 Hz
    Input Types Universal (Thermocouple, Platinum Resistance Thermometer, Analog Current/Voltage)
    Sampling Period 60 ms
    Indication Accuracy Thermocouple/Pt: +/-0.1% of PV; Analog Input: +/-0.1% FS
    Display Resolution 5 digits (up to 0.01 degC)
    Panel Depth 78 mm
    Approximately 1.0 kg (including packaging)
    Operating Temperature -10 degC to +55 degC (with no icing or condensation)
    Ambient Operating Humidity 25% to 85% RH

    Installation Guidelines

    To ensure optimal heat dissipation and electrical noise immunity, mount the controller securely into a standard 1/16 DIN panel cutout (45 x 45 mm). Keep the ventilation openings on the top and bottom of the housing clear of obstructions. When wiring the signal inputs, use shielded twisted-pair cables to protect against electromagnetic interference (EMI). Route power cables separately from low-voltage sensor input wiring to prevent noise injection. Ensure the ambient operating temperature remains within the specified -10 degC to +55 degC range.

    FAQ

    What sensor types are supported by the Omron E5CN-HQ2M-500-AC100-240?

    It features a universal input that supports thermocouple, platinum resistance thermometer (Pt100/JPt100), and analog voltage or current inputs.

    What is the sampling rate of the E5CN-HQ2M-500-AC100-240?

    This model has a high-speed sampling cycle of 60 milliseconds.

    What software is used to configure logic operations for this temperature controller?

    Flexible contact outputs and logic operations (AND, OR, and delays) are configured using Omron's CX-Thermo Version 4.0 software or higher.

    Does the unit include preventive maintenance features?

    Yes, it contains a Control Output ON/OFF Counter to monitor relay degradation and alert operators for scheduled preventive maintenance.

    View all FAQs →

    Quantity
    Shipping & Returns

    Global Express Shipping

    • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
    • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
    • Worldwide Coverage: Serving over 150 countries.

    Returns & Warranty

    • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
    • 12-Month Warranty: Every industrial component is backed by our technical warranty.
    Reviews
    1 of 1
    Only 3 item(s) left in stock
    Quantity
    View full details

    Global Express Shipping

    • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
    • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
    • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

    Returns & Warranty

    • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
    • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

    Orders are processed and delivered Monday-Friday (excluding public holidays).


    For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

    TECHNICAL SPECIFICATIONS

    Country of origin
    Japan

    Technical knowledge

    Designing Power and Communication Redundancy

    Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.

    Troubleshooting Industrial Control Cabinets Systematically

    A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.

    Measuring Voltage in Industrial Control Circuits

    A practical voltage-testing guide for industrial control panels, covering reference points, meter selection, live-dead-live checks, voltage drop, ghost voltage, stored energy and intermittent faults.

    Building a Verifiable Lockout Tagout Procedure

    A practical lockout tagout guide covering hazardous-energy identification, isolation, stored-energy control, verification, group work, temporary testing, restoration, inspections and audits.

    Designing Compressed-Air Preparation at the Machine

    A field guide to point-of-use compressed-air preparation covering filters, regulators, drains, dryers, lubrication, pressure loss, isolation, monitoring, commissioning and leak testing.

    Selecting Pneumatic Valve Actuation and Safe States

    A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.