Omron NX-OD2258 | Omron | NX-series Digital Transistor Output Unit
SKU NX-OD2258
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
Omron
Product No.:
NX-OD2258
Country of origin:Japan
Product Type:
Transistor Output Unit
Payment:
T/T, Western Union
Weight:
1000g
Shipping port:
Xiamen
Warranty:
12 months
Description
The NX-OD2258 is a high-speed digital transistor output unit within the NX-series I/O system, designed for precision control applications requiring exact signal timing. This module features 2 digital outputs with PNP transistor configuration, capable of switching up to 0.5 A per point at a voltage range of 15.0 to 28.8 VDC. Engineered for high-speed performance, the NX-OD2258 supports Timestamp signal processing, allowing for precise output triggering synchronized with the EtherCAT network cycle. The unit utilizes a screwless push-in connector for efficient wiring and is housed in a slim 12 mm wide enclosure, making it ideal for compact, high-density I/O configurations.
Features
Output Configuration: 2 digital outputs, PNP type
Precision Control: High-speed response with Timestamp capability for synchronized operation
Electrical Ratings: 0.5 A per point, 1 A total per NX unit
Protection: Integrated short-circuit protection for outputs
Design: Compact 12 mm wide module for optimized panel space
Applications
High-speed motion control and sequencing
Precision timing and event triggering in automated production lines
Synchronized actuators and solenoid control
Time-critical data logging and output operations
Technical Specifications
Parameter
Specification
Manufacturer
Omron
Model
NX-OD2258
I/O Type
Digital Transistor Output
Number of Outputs
2
Output Type
PNP
Load Current
0.5 A per point (1 A max per unit)
Permitted Voltage
15.0 to 28.8 VDC
OFF/ON Delay
0 to 0.3 ms
Protection
Short-circuit protected
Connection
Screwless push-in
Degree of Protection
IP20
Dimensions
104.5 mm x 12 mm x 80.1 mm
Weight
65 g
Installation Guidelines
Mounting: Ensure the module is properly clicked into the NX-series I/O bus connector on the DIN rail. Confirm the release lever is fully engaged.
Wiring: Utilize the screwless push-in connection system. Strip wires to the recommended length (typically 8–10 mm) and insert directly. Use a flat-blade screwdriver to release wires when necessary.
Grounding: Maintain the integrity of the functional ground connected to the NX-series system to ensure optimal noise immunity.
Synchronization: When using the Timestamp feature, ensure the controller/master is correctly configured for distributed clock (DC) synchronization to realize the benefits of high-speed timing.
FAQ
What is the benefit of the Timestamp function in the NX-OD2258?
The Timestamp function allows for high-precision output switching synchronized with the system's distributed clock, enabling much more accurate event timing than standard asynchronous I/O.
What is the maximum current capacity for this module?
The module is rated for 0.5 A per output point, with a maximum total load of 1 A per NX unit.
How do you connect wires to the NX-OD2258?
This unit uses a screwless push-in terminal connection, which allows for direct insertion of solid wires or ferrules, and uses a spring-clamp mechanism to secure the wire without screws.
Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.
A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...
A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...
Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...
Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...
Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.