Description

Designed for high-speed, high-precision machine control, the NX701-1600 centralizes motion, logic, and industrial communication within a single, unified execution engine. This Sysmac NX7 series controller coordinates complex multi-axis motion sequences while handling demanding database transactions and network communication tasks. By combining sequence control, motion control, and open communication standards like OPC-UA, this unit serves as a robust processing core for large-scale industrial automation architectures.

The unit connects directly to the high-speed NX I/O bus system, ensuring rapid data exchange with local I/O modules. Equipped with built-in dual-network interfaces, it facilitates seamless horizontal integration across the factory floor and vertical integration into enterprise IT systems without requiring additional communication hardware.

Features

  • Supports coordination of up to 128 synchronized motion axes, including virtual axes, for complex multi-axis machinery.
  • Delivers a high-speed primary task cycle time of 0.125 ms to meet the demands of highly dynamic applications.
  • Features integrated communication interfaces including an EtherCAT Master port, EtherNet/IP, and standard Ethernet TCP/IP.
  • Allocates substantial memory resources with 80 MB of program memory and 260 MB of variables memory to handle complex automation scripts.
  • Supports integrated sequence and motion control along with native OPC-UA server functionality.
  • Utilizes the high-bandwidth NX I/O bus system for rapid local module communications.

Applications

  • High-speed packaging and filling machinery
  • Semiconductor manufacturing and assembly systems
  • Multi-axis robotic integration and synchronized kinematics
  • Automated warehousing and material handling sorting lines
  • Continuous web handling and metal forming systems

Technical Specifications

Manufacturer Omron
Part Number/Model NX701-1600
Series Sysmac NX7
Controller Functionality Motion control, Sequence control, OPC-UA
Primary Task Cycle Time 0.125 ms
Program Memory 80 MB
Variables Memory 260 MB
Max. Synchronous Axes 128
Max. Total Axes 128 (including virtual axes)
Communication Ports EtherCAT Master, EtherNet/IP, Ethernet TCP/IP
I/O System Compatibility NX I/O Bus
Weight 0.88 Kg

Installation Guidelines

When installing the controller, mount the unit securely onto a standard 35 mm DIN rail within a clean, dry, and dust-free control cabinet. Ensure adequate ventilation clearance around the module to prevent heat buildup. All high-speed communication cables, especially EtherCAT and EtherNet/IP connections, should use high-quality shielded category 5e (or higher) cabling to minimize electromagnetic interference. Establish a low-impedance functional ground connection directly to the main system ground bar during electrical setup.

FAQ

What is the primary task cycle time of the Omron NX701-1600?

The NX701-1600 achieves a fast primary task cycle time of 0.125 ms, making it highly suitable for high-speed, dynamic synchronization applications.

How many synchronized axes can this controller manage?

The controller can manage up to 128 synchronized axes, which includes both physical and virtual axes.

What integrated communication protocols are supported on-board?

It features built-in ports and support for EtherCAT Master, EtherNet/IP, and standard Ethernet TCP/IP protocols.

What are the memory allocations for programming and variables?

The NX701-1600 is equipped with 80 MB of program memory and 260 MB of variables memory to accommodate complex logic and data manipulation.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.