Description
Designed for seamless integration into high-reliability safety networks, the Omron NXSL3300 safety CPU module delivers robust, decentralized safety control functionality within the Sysmac automation platform. Operating on the high-speed NX I/O bus system, this safety controller executes safety programs independently from standard machine automation controllers, ensuring non-interrupted protection and high-speed safety loop execution.
The NXSL3300 is engineered to meet stringent global safety standards, enabling system designers to build safety control circuits that satisfy SIL 3 and PL e requirements. By combining this module with NX-series safety I/O units and an EtherCAT coupler, engineers can construct a modular, scalable, and highly flexible safety network topology using the Safety over EtherCAT (FSoE) protocol.
Features
- Achieves Safety Integrity Level 3 (SIL 3) according to IEC 61508 and Category 4, PL e according to ISO 13849-1.
- Supports up to 512 kByte of dedicated safety program memory for complex safety logic implementation.
- Integrates natively with the Omron Sysmac Studio software environment, allowing unified programming of safety, logic, and motion.
- Facilitates modular safety system expansion via the high-speed NX I/O bus interface.
- Ultra-compact 30 mm width reduces required cabinet panel space.
Applications
- Automotive assembly lines and robotic workcells requiring high-integrity safety interlocking.
- Packaging machinery and material handling systems requiring safe speed monitoring and emergency stop integration.
- Process control systems needing independent, safety-rated shutdown systems.
- Complex machinery requiring distributed safety networks over EtherCAT (FSoE).
Technical Specifications
Manufacturer
| Omron |
Part Number / Model
| NXSL3300 |
Series
| NX Series (Sysmac Platform) |
Module Type
| Safety CPU Unit |
I/O System Connection
| NX I/O Bus |
Safety Integrity Level
| SIL 3 (IEC 61508) |
Performance Level
| PL e (ISO 13849-1) |
Program Memory Capacity
| 512 kByte |
Onboard Communication Ports
| None (communicates via host NX bus coupler) |
Width
| 30 mm |
Height
| 100 mm |
Depth
| 71 mm |
Weight
| 0.075 kg |
Installation Guidelines
- Mount the unit on standard 35 mm DIN rail (IEC 60715) within an IP54 or higher industrial enclosure.
- Ensure the system power supply is completely switched off before mounting or removing the module to prevent electrical damage to the NX bus connections.
- Maintain clear ventilation channels above and below the module assembly in accordance with standard cabinet layouts.
- Use functional grounding integrated into the DIN rail track to ensure stable performance and noise immunity.
Compliance and Certifications
- CE Mark
- cULus Listed
- KC Registration
- TUV Rheinland Certified for IEC 61508 SIL 3 and ISO 13849-1 PL e