Schneider Electric

Schneider Electric TM3AI8 Modicon TM3 Analog Input Module

SKU TM3AI8

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Schneider Electric

  • Product No.: TM3AI8

  • Country of origin:France

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 220g

  • Dimensions: 12,6cm x 10,51cm x 7,37cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for seamless integration with Modicon M221, M241, and M251 logic controllers, the TM3AI8 expansion module expands system capabilities by providing high-density analog data acquisition. This analog input module features eight high-resolution input channels, enabling precise monitoring of industrial variables such as temperature, pressure, and flow. By facilitating reliable signal conversion and real-time data transmission to the host PLC, it ensures optimal process control across diverse automation architectures.

The compact design of the Modicon TM3 system allows for efficient use of cabinet space. It mounts directly onto a standard DIN rail and connects to adjacent modules via an integrated bus expansion connector, minimizing wiring complexity and installation time.

Features

  • Eight high-density analog input channels supporting multiple signal ranges.
  • Compatible with Modicon M221, M241, and M251 controller ranges.
  • High-resolution analog-to-digital conversion for precise process measurement.
  • Compact form factor designed to optimize control cabinet space.
  • Simple interlocking assembly with integrated bus connector for rapid system expansion.

Applications

  • Water and wastewater treatment facilities.
  • Packaging, material handling, and assembly machinery.
  • HVAC and environmental control systems.
  • Food and beverage processing lines.
  • General factory automation and machine control.

Technical Specifications

Manufacturer Schneider Electric
Part Number/Model TM3AI8
Series Modicon TM3
Module Type Analog Input Module
Number of Inputs 8
Input Types 0...10 V, -10...10 V, 0...20 mA, 4...20 mA
Analogue-to-Digital Conversion 11 bits + sign or 12 bits
LSB Value 2.44 mV (0...10 V), 4.88 mV (-10...10 V), 4.88 microA (0...20 mA), 3.91 microA (4...20 mA)
Permissible Continuous Overload 13 V (voltage), 40 mA (current)
Input Impedance >= 1 MOhm (voltage), <= 250 Ohm (current)
Isolation Between input and internal logic: 1500 V AC
Between inputs: Non-isolated
Current Consumption 30 mA at 5 V DC (via bus)
40 mA at 24 V DC (via bus)

Connections and Interfaces

Terminal Connection Function
I0+ to I7+ Positive analog input channels 0 to 7
I0- to I7- Negative analog input channels 0 to 7
Shield / Functional Ground Shield connection point for signal noise reduction

Installation Guidelines

  • Mounting: Mount the module horizontally or vertically on a 35 mm DIN rail (AM1 DE200 or equivalent).
  • Shielding: Use shielded twisted-pair cables for all analog input connections to minimize electromagnetic interference. Ground the shield at a single point, preferably on the controller side.
  • Wiring: Keep analog signal wiring physically separated from high-voltage power lines and motor drive cables.
  • Thermal Management: Ensure adequate ventilation clearance around the module as specified in the Modicon TM3 hardware guide, maintaining operating temperatures within rated limits.

Compliance and Certifications

  • CE
  • cULus Listed
  • UKCA
  • RCM

FAQ

Which PLCs are compatible with the TM3AI8 analog module?

The TM3AI8 is designed for use with Schneider Electric Modicon M221, M241, and M251 logic controllers.

What analog input signal types does the TM3AI8 support?

The module supports 0 to 10 V, -10 to +10 V, 0 to 20 mA, and 4 to 20 mA input signals.

Are the input channels on the TM3AI8 isolated from each other?

No, the input channels are non-isolated from each other, but they feature 1500 V AC isolation between the inputs and the internal logic circuitry.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
France

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.