Siemens 6AV7612-0AA13-0CH0 SIMATIC Panel PC 670

SKU 6AV7612-0AA13-0CH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA13-0CH0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 55.0 x 45.0 x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AA13-0CH0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a 12-inch TFT touch display, providing a clear and interactive operator interface. It is configured with a Celeron 500 MHz CPU, 64 MB of RAM, and a 20 GB hard drive. The system comes pre-installed with the Windows NT 4.0 operating system in German and includes a European mains cable for power connection.

Features

  • 12-inch TFT color display with touch functionality
  • Integrated Celeron processor operating at 500 MHz
  • Equipped with 64 MB of system RAM
  • Includes a 20 GB internal hard drive for storage
  • Pre-loaded with Windows NT 4.0 (German language)
  • Designed for 115-230V AC power input

Applications

  • Machine-level operator control and monitoring
  • Process visualization and data acquisition
  • Industrial control cabinet and panel mounting
  • Legacy system integration and replacement

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6AV7612-0AA13-0CH0
Product Series SIMATIC Panel PC 670
Display 12-inch TFT Touch Display
Processor (CPU) Celeron 500 MHz
Memory (RAM) 64 MB
Storage 20 GB Hard Drive (HD)
Operating System Windows NT 4.0 (German)
Input Voltage 115-230 V AC
Included Accessories European Mains Cable
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 55.0 x 45.0 x 25.0 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment and follow Lockout/Tagout (LOTO) procedures before installation can result in severe injury or death.
  1. 1 Prepare the Enclosure: Ensure the mounting panel is clean, flat, and correctly sized for the PC's cutout dimensions. Verify adequate clearance for ventilation and cable routing behind the unit.
  2. 2 Mount the Unit: Insert the Panel PC into the prepared cutout from the front of the panel. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure a proper seal.
  3. 3 Establish Ground Connection: Connect the chassis ground terminal on the Panel PC to the enclosure's main protective earth (PE) busbar using a low-impedance conductor. This is critical for safety and noise immunity.
  4. 4 Connect Power and Peripherals: With the main power still locked out, connect the 115-230V AC mains supply using the provided cable. Connect all required communication, USB, and other I/O cables, ensuring proper strain relief.
  5. 5 Final Checks and Power-Up: Verify all connections are secure and correctly terminated. Remove all tools from the enclosure. After completing all safety checks and removing the LOTO device, apply power to the unit and verify correct boot-up and operation.

FAQ

What operating system is installed on the 6AV7612-0AA13-0CH0?

This Panel PC comes pre-installed with Windows NT 4.0 in the German language version.

What are the core hardware specifications of this unit?

It is equipped with a Celeron 500 MHz processor, 64 MB of RAM, and a 20 GB hard drive for storage.

What is the display size and type?

The unit features a 12-inch TFT display with integrated touch screen functionality for operator interaction.

What is the required input voltage for this Panel PC?

The device is designed for a mains power supply of 115-230V AC. A European mains cable is included with the unit.

Is this a current product from Siemens?

No, the 6AV7612-0AA13-0CH0 is listed with a product lifecycle status of 'Obsolete'. It is suitable for spares or maintaining existing legacy systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.