The Siemens 6AV7612-0AE30-0CJ0 is a SIMATIC Panel PC 670, an integrated human-machine interface (HMI) designed for industrial control and visualization tasks. This unit is equipped with a 12-inch TFT touch display, a 300 MHz Celeron CPU, 256 MB of RAM, and a 40 GB hard drive. It operates on a 115-230V AC power supply and comes pre-installed with the Windows NT 4.0 English operating system. This model is part of the established SIMATIC HMI family, providing a robust platform for machine-level applications.
Features
- Integrated 12-inch TFT color display with touch functionality
- Powered by a Celeron 300 MHz processor
- Includes 256 MB of system RAM
- Features a 40 GB internal hard drive for data and application storage
- Pre-loaded with Microsoft Windows NT 4.0 (English version)
- Wide input voltage range of 115-230V AC
- Supplied with a European mains power cable
Applications
- Machine-level operator control and monitoring
- Process visualization and data acquisition
- Factory automation control panels
- Industrial data logging and recipe management
- Legacy system integration requiring Windows NT
Technical Specifications
| Specification |
Value |
| Product Type |
Panel PC |
| Display |
12-inch TFT Touch Display |
| Processor (CPU) |
Celeron 300 MHz |
| Memory (RAM) |
256 MB |
| Storage |
40 GB Hard Drive (HD) |
| Operating System |
Windows NT 4.0 (English) |
| Input Power |
115-230 V AC (Supplied with European mains cable) |
| Product Lifecycle Status |
Obsolete |
| Shipping Weight |
4.00 kg |
| Commodity Code |
85371091 |
| Export Control (ECCN) |
N |
| Manufacturer |
Siemens |
| Country of Origin |
Germany (Estimate) |
| Package Dimensions (Calculated) |
40 x 30 x 15 cm |
Installation Guidelines
CRITICAL WARNING: Disconnect all power sources and follow Lockout/Tagout (LOTO) procedures before installation or servicing. Failure to de-energize the system can result in severe electrical shock, equipment damage, or personal injury.
-
1
Panel Cutout & Mounting: Prepare the control cabinet panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid. Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified ingress protection rating.
-
2
Power Connection: Connect the supplied mains cable to the unit's power input terminal. Route the power cable away from high-noise sources and data lines. Ensure the source voltage (115-230V AC) matches the panel's rating before energizing.
-
3
Protective Earth (PE) Grounding: Connect the designated protective earth terminal on the Panel PC chassis to the main control cabinet ground bus using a low-impedance conductor. A reliable ground connection is critical for operator safety and electromagnetic compatibility (EMC).
-
4
Interface Cabling: Connect all required communication and I/O cables (e.g., Ethernet, serial, USB). Use shielded cables where specified and ensure shields are properly terminated at one end, typically the cabinet ground, to prevent ground loops.
-
5
System Power-Up: After verifying all connections, remove LOTO devices and apply power to the cabinet. The Panel PC should boot into its pre-installed operating system. Proceed with application-specific software configuration.