Description
The Siemens 6AV7672-2AD00-0AA0 is a SIMATIC Panel PC 577 complete spare front, designed for industrial applications. This unit features a 15-inch TFT display, integrated membrane keys, and a mouse, providing a comprehensive operator interface. It serves as a replacement component within the Simatic Panel PC range, ensuring continued operation and maintainability of existing systems. This particular product phase is noted as obsolete.
Features
- 15-inch TFT Display
- Integrated Membrane Keys
- Integrated Mouse Functionality
- Designed as a Complete Spare Front Unit
- Part of the Siemens SIMATIC Panel PC 577 Series
Applications
This spare front unit is typically deployed in industrial environments requiring human-machine interface (HMI) functionality. Common applications include:
- Replacement in existing SIMATIC Panel PC 577 installations
- Process visualization and control in manufacturing plants
- Machine operation and monitoring in automated systems
- Data entry and system diagnostics in industrial settings
Technical Specifications
| Parameter |
Value |
| Manufacturer |
Siemens |
| Range |
Simatic Panel PC |
| Type of Product |
PC panels |
| Product Phase |
Obsolete |
| Package Dimensions (Calculated) |
51.00 x 66.50 x 21.00 cm |
| Shipping Weight |
4.50 kg |
| Commodity Code |
85366990 |
| Export Control Regulations (ECCN) |
N |
Installation Guidelines
-
Safety First: Ensure the host SIMATIC Panel PC system is completely de-energized and locked out according to local safety procedures before beginning any work.
-
Access Existing Unit: Carefully open the Panel PC enclosure to gain access to the existing front unit. Disconnect any internal cables or connectors attached to the old front.
-
Remove Old Front: Unfasten all mounting screws or clips securing the old front unit to the Panel PC chassis. Gently remove the old unit.
-
Prepare New Front: Inspect the new 6AV7672-2AD00-0AA0 spare front for any shipping damage.
-
Install New Front: Align the new spare front with the Panel PC chassis. Ensure all mounting points are correctly positioned.
-
Secure Unit: Fasten the new front unit using the appropriate mounting screws or clips. Ensure a secure and flush fit to maintain environmental sealing.
-
Reconnect Cables: Carefully reconnect all internal cables and connectors to the new front unit, ensuring correct polarity and seating.
-
Close Enclosure: Close and secure the Panel PC enclosure.
-
Power Up and Test: Re-energize the Panel PC system and perform functional tests of the display, membrane keys, and mouse to confirm proper operation.