Description

The Siemens 6AV7820-0AA10-1AC0 is a panel-mounted human-machine interface (HMI) from the SIMATIC Panel PC 577 series. This unit integrates a 12-inch touch display with an industrial computer powered by a Celeron 2.0 GHz processor and 512 MB of DDR400 SDRAM. It is equipped with an integrated DVD-ROM drive and comes pre-installed with the Windows XP SP1 Professional Multi-Language User Interface (MUI) operating system, providing a ready-to-deploy platform for machine control and process visualization tasks.

Features

  • ■12-inch color touch display for operator interaction.
  • ■Celeron processor operating at 2.0 GHz.
  • ■512 MB DDR400 SDRAM for application support.
  • ■Integrated DVD-ROM optical drive.
  • ■Pre-loaded with Windows XP SP1 Professional (MUI).

Applications

  • ■Machine-level operator control and monitoring.
  • ■Process visualization and data acquisition (SCADA).
  • ■Factory automation and production line management.
  • ■Data logging and recipe management systems.

Technical Specifications

Specification Value
General
Brand Siemens
Part Number 6AV7820-0AA10-1AC0
Series SIMATIC Panel PC 577
Product Type Panel PC
Product Lifecycle Status Obsolete
Performance
Processor Celeron 2.0 GHz
Memory 512 MB DDR400 SDRAM
Display
Size 12 inch
Type Touch Display
Storage
Optical Drive DVD-ROM
Software
Operating System Windows XP SP1 Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)
Logistics and Compliance
Shipping Dimensions 64.0 x 64.0 x 42.0 cm
Shipping Weight 15.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Manufacturer Siemens
Package Dimensions (Calculated) 64.0 x 64.0 x 42.0 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages may be present. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out (LOTO) before commencing any installation or maintenance activities. Failure to comply can result in severe injury or death.
  1. 1 Prepare the panel cutout according to the device's mechanical drawings, ensuring sufficient clearance for ventilation and cable routing. Deburr all sharp edges.
  2. 2 Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the specified torque to ensure a proper seal.
  3. 3 Connect a low-impedance protective earth (PE) ground wire to the designated grounding terminal on the Panel PC chassis. This is critical for both safety and noise immunity.
  4. 4 Connect the main power supply to the unit, verifying the source voltage matches the rating on the device label. Ensure power cabling is segregated from high-noise signal or power lines.
  5. 5 Connect all required communication and I/O cables (e.g., Ethernet, USB, serial). Use shielded cables where specified and ensure shields are properly terminated to ground.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.