The Siemens 6AV7872-0HD31-1AC0 is a SIMATIC Panel PC 677B, designed for industrial human-machine interface (HMI) and control applications. This robust Panel PC features a 15-inch touch display with a resolution of 1024 x 768 pixels, providing a clear and interactive operator interface. It is equipped with an Intel Core 2 Duo T5500 processor running at 1.66 GHz, supported by 2 GB of DDR2 RAM and a 250 GB SATA hard disk drive. For data storage and media access, it includes a 3.5-inch DVD+-R+-RW drive.
Connectivity options are comprehensive, including two 10/100/1000 Mbit/s Ethernet ports, four USB V2.0 ports (with a front-side USB interface), and one serial (COM1) port. Industrial communication is further enhanced with an integrated PROFIBUS/MP interface and 2 MB of buffered SRAM. The unit operates on a 110/230 V AC power supply unit with NAMUR support and is supplied with a power supply cable suitable for China. It comes pre-installed with Windows XP Professional MUI, supporting multiple languages (de, en, fr, es, it, ja, zh, ko), making it suitable for diverse global industrial environments.
Features
- Integrated 15-inch touch display with 1024 x 768 resolution.
- Equipped with Intel Core 2 Duo T5500 processor (1.66 GHz) and 2 MB SLC.
- Includes 2 GB DDR2 RAM and a 250 GB SATA HDD (3.5").
- Multiple communication interfaces: 2x 10/100/1000 Mbit/s Ethernet, 4x USB V2.0, 1x serial (COM1), PROFIBUS/MP.
- Features 1x PCIE X4 and 1x PCI expansion slots.
- Integrated DVD+-R+-RW optical drive.
- Pre-installed Windows XP Professional MUI operating system (multi-language).
- Supports 110/230 V AC power supply with NAMUR functionality.
Applications
The Siemens SIMATIC Panel PC 677B is suitable for a wide range of industrial automation applications, including:
- Human-Machine Interface (HMI) for machine operation and control.
- Process visualization and monitoring in manufacturing plants.
- Data acquisition and processing in industrial environments.
- Embedded control systems requiring local processing and display.
- Operator workstations in production lines and control rooms.
Technical Specifications
| Parameter |
Value |
| Brand |
Siemens |
| Manufacturer |
Siemens |
| Product Range |
SIMATIC Panel PC |
| Subrange |
PC677B |
| Product Type |
Panel PC |
| Product Phase |
Obsolete |
| Processor |
Core 2 Duo T5500, 1.66 GHz |
| Cache |
2 MB SLC |
| RAM |
2 GB DDR2 |
| Hard Drive |
250 GB SATA HDD 3.5" |
| Optical Drive |
DVD+-R+-RW |
| Display Size |
15 inches |
| Display Resolution |
1024 x 768 |
| Ethernet Ports |
2x 10/100/1000 Mbit/s |
| USB Ports |
4x USB V2.0 (with front-side USB interface) |
| Serial Ports |
1x (COM1) |
| Expansion Slots |
1x PCIE X4, 1x PCI |
| Fieldbus Interface |
PROFIBUS/MP |
| Buffered SRAM |
2 MB |
| Operating System |
Windows XP Professional MUI (de,en,fr,es,it,ja,zh,ko) |
| Power Supply |
110/230 V AC with NAMUR |
| Power Supply Cable |
China |
| Country of Origin |
Unknown |
| Package Dimensions (Calculated) |
67.00 x 83.00 x 11.50 cm |
| Shipping Weight |
17.00 kg |
| Commodity Code |
85371098 |
| Export Control Regulations (ECCN) |
N |
Connections / Interfaces
| Interface Type |
Quantity / Description |
| Ethernet |
2x 10/100/1000 Mbit/s |
| USB |
4x USB V2.0 (including front-side interface) |
| Serial |
1x (COM1) |
| Fieldbus |
PROFIBUS/MP |
| Expansion Slots |
1x PCIE X4, 1x PCI |
Installation Guidelines
-
Safety First: Ensure all power to the installation area is de-energized and locked out before commencing any work.
-
Mounting: Securely mount the Panel PC in a suitable industrial enclosure or panel cutout, ensuring adequate ventilation for heat dissipation.
-
Power Connection: Connect the 110/230 V AC power supply unit according to local electrical codes and the NAMUR standard, if applicable. Verify correct voltage and polarity.
-
Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
-
Peripheral Connections: Connect Ethernet cables to the 10/100/1000 Mbit/s ports, USB devices to the USB V2.0 ports, and serial devices to the COM1 port as required by the application.
-
PROFIBUS/MP Connection: If utilizing the PROFIBUS/MP interface, ensure correct cabling and termination according to PROFIBUS guidelines.
-
Environmental Considerations: Ensure the operating environment meets the specified temperature, humidity, and vibration ratings for industrial Panel PCs to ensure reliable operation.
-
Initial Power-Up: After all connections are verified, apply power and observe the system startup.