Siemens

Siemens 6ES7134-4GB10-0AB0 SIMATIC ET 200S Analog Input Module

SKU 6ES7134-4GB10-0AB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7134-4GB10-0AB0

  • Country of origin:Germany

  • Product Type: Analog Input Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 10.5 x 12.5 x 4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7134-4GB10-0AB0 is a high-precision, two-channel analog input module designed for the SIMATIC ET 200S distributed I/O system. This module provides accurate process variable measurement from field instruments in a compact 15mm width housing. It features two isolated channels and supports dual input ranges, including ±20mA current with a resolution of 13-bits plus sign, and 4-20mA signals at 12-bit resolution for 4-wire transducers. With a fast cycle time of 65ms per channel, it is suitable for applications requiring responsive process monitoring and control.

Features

  • Two electrically isolated analog input channels
  • Dual-range capability: ±20mA and 4-20mA
  • High-resolution A/D conversion (up to 13-bit + sign)
  • Space-saving 15mm module width for high-density I/O
  • Integrated SF (Group Fault) LED for immediate diagnostics
  • Seamless integration into PROFIBUS networks via the ET 200S system

Applications

  • Process control systems in water treatment and chemical processing
  • Energy management and monitoring systems
  • Interfacing with pressure transmitters, flow meters, and other 4-20mA field devices
  • High-density analog signal acquisition in space-constrained control cabinets

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6ES7134-4GB10-0AB0
Product Family SIMATIC ET 200S
Module Type Analog Input Electronics Module
Number of Inputs 2, Isolated
Input Range 1 ±20mA
Resolution (Range 1) 13 bits + sign
Input Range 2 4-20mA (for 4-wire transducers)
Resolution (Range 2) 12 bits
Cycle Time per Channel 65 ms
Module Width 15 mm
Diagnostics SF (Group Fault) LED
Shipping Weight 0.24 kg
Package Dimensions 10.5 x 12.5 x 4 cm
Country of Origin Germany
HS Code 8537101190

Installation Guidelines

CRITICAL WARNING: Hazardous voltages may be present. Installation must be performed by qualified personnel only. Ensure all power sources to the ET 200S station and related equipment are de-energized and locked out (LOTO) before proceeding.
  1. 1 Verify that the module part number 6ES7134-4GB10-0AB0 matches the project requirements and that the module is free from any visible shipping damage.
  2. 2 Align the electronics module with the corresponding ET 200S terminal module (e.g., TM-E15... or TM-P15...) and press firmly until it clicks securely into place on the backplane bus.
  3. 3 Terminate the analog input signal wires at the correct terminals on the terminal module. Use shielded, twisted-pair instrumentation cable for all analog signals to minimize electrical noise interference.
  4. 4 Connect the cable shields to a dedicated, low-impedance ground point at the cabinet end only to prevent ground loops. Ensure proper grounding of the DIN rail and control panel.
  5. 5 After all modules are installed and wired, remove the lockout/tagout devices and re-apply power to the system. Verify that the module's diagnostic LEDs indicate normal operation.

FAQ

What I/O system is this module designed for?

The 6ES7134-4GB10-0AB0 is specifically designed for the Siemens SIMATIC ET 200S distributed I/O system.

What are the supported analog current input ranges?

This module supports two distinct current input ranges: ±20mA and 4-20mA, making it compatible with a wide variety of 4-wire field transducers.

How many input channels does this module have?

It features two electrically isolated analog input channels, allowing for the measurement of two independent process variables.

What is the physical width of the module?

This is a compact module with a width of just 15mm, which helps to save valuable space in high-density control cabinets.

Does this module provide any diagnostic feedback?

Yes, it includes an integrated SF (Group Fault) LED that provides an immediate visual indication of a module or channel fault for efficient troubleshooting.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...