Siemens

Siemens 6ES7134-6HD00-0BA1 SIMATIC ET 200SP Analog Input Module

SKU 6ES7134-6HD00-0BA1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7134-6HD00-0BA1

  • Country of origin:Germany

  • Product Type: PLC Analog Input Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 950g

  • Dimensions: 2.5 x 5.1 x 83.8 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6ES7134-6HD00-0BA1 analog input module for the SIMATIC ET 200SP distributed I/O system. It is engineered to process signals from field instrumentation through its four isolated input channels, providing precise data acquisition for industrial control applications. The module integrates comprehensive diagnostic functions to ensure high operational reliability and immediate fault detection, making it suitable for systems where uptime and signal integrity are critical. Its capabilities include monitoring for field-side power supply failures, sensor wire breaks, and short-circuits, delivering detailed status information to the control system for proactive maintenance and rapid troubleshooting.

Features

  • ■Engineered for the SIMATIC ET 200SP I/O system.
  • ■Provides four channels for analog signal input.
  • ■Integrated diagnostics for supply voltage (L+) failure.
  • ■Detects wire breaks and short-circuits to ground on input channels.
  • ■Monitors for signal overflow and underflow conditions.
  • ■Supports accessories such as labeling strips and shield connectors for system integration.

Applications

  • ■Process control systems requiring precise analog value acquisition.
  • ■Factory automation for monitoring sensors and transducers.
  • ■Machine control where high availability and fault diagnostics are necessary.
  • ■Distributed I/O architectures in manufacturing and infrastructure.

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6ES7134-6HD00-0BA1
Product Type Analog Input Module
Product Family SIMATIC ET 200SP
Number of Channels 4
Condition Brand New
Lifecycle Status Active
Shipping Weight 0.95 kg
Package Dimensions (Calculated) 2.5 cm x 5.1 cm x 83.8 cm
Country of Origin Germany
HS Code 8537101190

Installation Guidelines

CRITICAL WARNING: Electrical hazard. Installation, modification, or removal of this module must be performed only by qualified personnel. Failure to de-energize the system and follow Lockout/Tagout (LOTO) procedures before servicing can result in severe injury or death.
  1. 1 Verify that the part number 6ES7134-6HD00-0BA1 matches the system design requirements before unsealing the anti-static packaging.
  2. 2 Ensure the backplane bus and power supply are completely de-energized and locked out. Confirm zero-energy state with a calibrated multimeter.
  3. 3 Mount the module onto the corresponding ET 200SP BaseUnit on the DIN rail, ensuring it is securely seated and the locking mechanism engages correctly.
  4. 4 Connect pre-stripped field wiring to the terminals on the BaseUnit. Use shielded, twisted-pair cabling for analog signals to minimize electromagnetic interference.
  5. 5 Terminate the cable shield to a designated functional earth (FE) or protective earth (PE) terminal at the cabinet ground bar to ensure proper signal integrity.
  6. 6 After all connections are verified, remove LOTO devices and re-energize the system. Proceed with software configuration and commissioning of the analog input channels.

FAQ

What control system is the 6ES7134-6HD00-0BA1 module designed for?

This module is designed for use within the Siemens SIMATIC ET 200SP distributed I/O system.

How many input channels does this module have?

The 6ES7134-6HD00-0BA1 features four analog input channels for connecting field sensors and transmitters.

What are the key diagnostic functions of this analog input module?

It provides comprehensive diagnostics for supply voltage failure, short-circuits to ground, sensor wire breaks, and signal overflow or underflow conditions to ensure high system availability.

Is this an active and current Siemens product?

Yes, according to the source information, this module is an active product and is not discontinued.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.