Description

The Siemens 6ES7313-6CE00-0AB0 is a compact CPU module for the SIMATIC S7-300 PLC system, designed for small to medium-scale automation tasks in legacy installations. This module integrates a comprehensive set of I/O and communication features, including 16 digital inputs, 16 digital outputs, and three high-speed counters rated for 30 kHz. It operates on a 24V DC power supply and utilizes a 32 KB working memory, which requires a separate Micro Memory Card (MMC) for operation. Communication is facilitated through an integrated PROFIBUS DP interface and an MPI port, enabling connectivity within industrial networks.

Features

  • ■Integrated 16 Digital Inputs (DI)
  • ■Integrated 16 Digital Outputs (DO)
  • ■Three integrated high-speed counters (30 kHz)
  • ■32 KB working memory for user program and data
  • ■Requires Siemens Micro Memory Card (MMC) for operation
  • ■Onboard PROFIBUS DP and MPI communication interfaces
  • ■Compact design for space-constrained control cabinets

Applications

  • ■Maintenance and support for existing SIMATIC S7-300 systems
  • ■Small-scale machine control
  • ■Process control and monitoring in legacy manufacturing lines
  • ■Distributed I/O control via PROFIBUS DP

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6ES7313-6CE00-0AB0
Product Series SIMATIC S7-300
Module Type Compact CPU Module
Power Supply 24V DC
Working Memory 32 KB
Memory Card Requirement Micro Memory Card (MMC)
Integrated Digital Inputs 16
Integrated Digital Outputs 16
High-Speed Counters 3 (up to 30 kHz)
Communication Interfaces PROFIBUS DP, MPI
Production Status Legacy / Discontinued
Shipping Weight 0.05 kg
Package Dimensions (Calculated) 1.5 cm x 5.5 cm x 8.3 cm
Country of Origin Germany
HS Code 8537101190

Installation Guidelines

CRITICAL WARNING: Hazardous voltages may be present. All installation and maintenance procedures must be performed by qualified personnel only. Failure to de-energize the system and follow proper Lockout/Tagout (LOTO) procedures before servicing can result in severe injury or death.
  1. 1
    De-energize Equipment: Before installation, completely disconnect and lock out all power sources to the control cabinet and associated machinery according to established LOTO safety protocols.
  2. 2
    Mount Module: Securely mount the module onto a standard 35mm DIN rail inside the control panel. Ensure there is adequate clearance for ventilation and cable routing. The module should click firmly into place.
  3. 3
    Connect Grounding: Connect the chassis ground terminal to the main panel protective earth (PE) busbar using a low-impedance conductor. A reliable ground connection is essential for noise immunity and safety.
  4. 4
    Wire Power and I/O: Connect the 24V DC power supply, communication cables (PROFIBUS/MPI), and field I/O wiring to the appropriate terminals. Use shielded cables for communication and analog signals, and ensure shields are properly terminated at one end.
  5. 5
    Insert Memory Card: With the power off, insert the required Micro Memory Card (MMC) into the designated slot on the CPU. The CPU will not operate without a valid MMC.
  6. 6
    Verify and Energize: Double-check all connections for correctness and security. Remove LOTO devices and re-apply power to the system. Verify module status indicators for correct operation before commissioning.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.