Description

This is a Siemens 6ES7647-7BK40-4XN0 SIMATIC IPC427C, a compact and robust Microbox PC designed for control cabinet installation. This specific configuration is equipped with an Intel Core2 Solo 1.2 GHz processor with an 800 MHz FSB and 3 MB SLC. It includes 4 GB of DDR3 1066 SODIMM memory and utilizes a replaceable 8 GB CompactFlash card for storage. The unit comes with Windows Embedded Standard 7 pre-installed on the CF card. This model does not feature hardware expansion slots or an additional internal drive.

Features

  • Processor: Intel Core2 Solo at 1.2 GHz
  • Memory: 4 GB DDR3 1066 SODIMM
  • Primary Storage: 8 GB replaceable CompactFlash card
  • Operating System: Windows Embedded Standard 7 pre-installed
  • Compact Microbox form factor for space-constrained applications
  • Designed for industrial environments
  • Product Lifecycle Status: Phase-Out

Applications

  • Human-Machine Interface (HMI) visualization tasks
  • Data logging and acquisition gateways
  • PC-based control and automation systems
  • Communication gateways in factory networks
  • Process monitoring and data concentration

Technical Specifications

Specification Value
Product Type Microbox PC
Series SIMATIC IPC427C
Processor Intel Core2 Solo
CPU Clock Speed 1.2 GHz
Front Side Bus (FSB) 800 MHz
Cache 3 MB SLC
Main Memory 4 GB DDR3 1066, SODIMM
Accessible Drive (Swappable) 8 GB CompactFlash
Internal Drive (Not Accessible) Not included
Hardware Expansion None
Operating System Windows Embedded Standard 7 (Pre-installed)
Product Lifecycle Status Phase-Out
Shipping Weight 3.25 kg
Commodity Code 85371091
ECCN N
Manufacturer Siemens
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 35 x 25 x 15 cm

Installation Guidelines

CRITICAL WARNING: Disconnect all power sources before installation or maintenance. This device contains components sensitive to electrostatic discharge (ESD). Use a grounded wrist strap and an anti-static mat when handling. Failure to follow safety procedures can result in equipment damage or personnel injury.
  1. 1 Ensure the control cabinet is de-energized and locked out. Verify zero voltage with a calibrated multimeter before proceeding.
  2. 2 Mount the IPC427C securely onto a standard DIN rail or a flat panel surface within the enclosure. Maintain specified clearances for ventilation to prevent overheating.
  3. 3 Connect the chassis grounding terminal directly to the main protective earth (PE) busbar using a low-impedance conductor of appropriate gauge.
  4. 4 Connect the 24 VDC power supply to the designated terminals, carefully observing correct polarity (+/-). Use of a stabilized and approved power supply is required.
  5. 5 Connect all required peripheral and network cables (e.g., Ethernet, USB, display). Ensure proper cable strain relief and routing away from high-voltage lines.
  6. 6 After verifying all connections, remove the lockout/tagout and re-energize the control cabinet. Monitor the IPC for a successful boot sequence.

FAQ

What processor is installed in this IPC?

It is equipped with an Intel Core2 Solo processor running at 1.2 GHz with an 800 MHz Front Side Bus and 3 MB SLC.

What is the primary storage medium for this device?

The unit uses an 8 GB replaceable CompactFlash (CF) card as its primary drive for the operating system and applications.

Does this unit come with a pre-installed operating system?

Yes, this model comes with Windows Embedded Standard 7 pre-installed on the replaceable CompactFlash card.

Can this Microbox PC be expanded with additional interface cards?

No, this specific configuration, 6ES7647-7BK40-4XN0, does not include hardware expansion slots for additional cards.

What is the product lifecycle status of the IPC427C?

This model is designated by the manufacturer as a 'Phase-Out' product, indicating it is nearing the end of its production life.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.