The Siemens 6GK5613-0BA00-2AA3 SCALANCE S613 is an industrial communication module designed for the robust protection of devices and networks within automation technology environments. This module integrates advanced firewall and VPN functionalities to secure industrial communication, supporting up to 64 devices for comprehensive network protection. The SCALANCE S 613 is engineered for continuous operation in demanding production settings where reliable cybersecurity is essential for operational integrity.

Features

  • Integrated firewall functionality for network protection
  • VPN support for secure industrial communication
  • Protects up to 64 devices via VPN
  • Designed for industrial automation environments
  • Robust construction for continuous operation

Applications

The Siemens 6GK5613-0BA00-2AA3 SCALANCE S613 module is suitable for deployment in various industrial automation scenarios requiring enhanced network security. Typical applications include:

  • Securing control systems and PLCs from unauthorized access
  • Protecting sensitive data transmission in industrial networks
  • Establishing secure remote access to automation devices via VPN
  • Implementing network segmentation with firewall rules
  • Safeguarding critical infrastructure in production facilities

Technical Specifications

Manufacturer Siemens
Brand Siemens
Range SCALANCE
Product Type Communication Module
PLM Product Phase Phase-Out
Package Dimensions (Calculated) 15.10 x 16.90 x 12.60 cm
Shipping Weight 0.92 kg
Commodity Code 85176200
Export Control Regulations (ECCN) N

Installation Guidelines

Proper installation and configuration are critical for the effective operation and security of the SCALANCE S613 module. Adhere to the following general guidelines:

  1. De-energize System: Before beginning any installation work, ensure that the power supply to the network components and the module's intended mounting location is completely de-energized and secured against accidental re-energization.
  2. Mounting: Mount the module securely in a suitable industrial enclosure or rack, typically on a DIN rail, ensuring adequate ventilation and clearance for cable routing.
  3. Power Connection: Connect the module to a stable and appropriate power supply according to the specified voltage range. Verify correct polarity before applying power.
  4. Network Connections: Connect industrial Ethernet cables to the module's network interfaces. Ensure proper cable routing to avoid interference and physical damage. Use shielded cables where appropriate to maintain signal integrity in noisy industrial environments.
  5. Grounding: Establish a reliable protective earth (PE) connection for the module and its associated equipment to minimize electromagnetic interference and ensure safety.
  6. Configuration: After physical installation, configure the firewall rules and VPN settings according to the network security policy. This typically involves using Siemens engineering software.
  7. Testing: Thoroughly test all communication paths and security functionalities (firewall, VPN) to confirm correct operation and adherence to security requirements before commissioning the system.

FAQ

What is the primary function of the Siemens 6GK5613-0BA00-2AA3 module?

The module's primary function is to provide robust security for industrial automation networks and devices through integrated firewall and VPN functionalities.

How many devices can the VPN feature support?

The VPN functionality of the SCALANCE S613 module supports the protection of up to 64 devices.

What is the product lifecycle status of this module?

The Siemens 6GK5613-0BA00-2AA3 SCALANCE S613 module is currently in the Phase-Out stage of its product lifecycle.

What are the physical dimensions of the module?

The package dimensions for the module are 15.10 x 16.90 x 12.60 cm.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...