Allen-Bradley

Allen-Bradley 1756-ENET ControlLogix Ethernet Communication Module

SKU 1756-ENET

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-ENET

  • Country of origin:United States

  • Product Type: Communication Module

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Overview

The Allen-Bradley 1756-ENET is a 10 Mbps Ethernet communication module for the 1756 ControlLogix chassis.

The recorded configuration includes RJ45 and AUI ports, scanner and adapter modes, explicit messaging, implicit messaging, and direct or rack-optimized connections.

Features

  • Dual physical ports including one RJ45 Ethernet port and one AUI (Attachment Unit Interface) port
  • Supports both scanner and adapter operational modes for flexible network architectures
  • Handles explicit messaging for configuration and programming alongside implicit messaging for real-time I/O data
  • Supports rack-optimized and direct connection methods to optimize controller backplane resource utilization
  • Occupies a single standard slot width in any 1756 ControlLogix chassis
  • Standard open-style industrial enclosure rating

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Exact Model 1756-ENET
Product Type ControlLogix Ethernet Communication Module
Supported Platform ControlLogix (1756)
Communication Rate 10 Mbps
Communication Ports 1 x Ethernet (RJ45), 1 x AUI
Backplane Current Draw 900 mA at 5.1V DC; 350 mA at 24V DC
Power Dissipation 13.3 W max.
Slot Width 1 Single Slot
Operating Temperature 0 to 60 degC (32 to 140 degF)
Enclosure Type Open
Country of Origin United States

Connections / Interfaces

The 1756-ENET module features two distinct physical connection options on the front faceplate to interface with network infrastructure:

  • Ethernet Port: Standard RJ45 connection used for connecting to 10 Mbps Ethernet local area networks.
  • AUI Port: Attachment Unit Interface port allowing connection via transceiver cables to older network media such as coaxial thicknet or thinnet infrastructures.

FAQ

What platform is the Allen-Bradley 1756-ENET designed to operate within?

The Allen-Bradley 1756-ENET is a legacy communication module specifically designed to operate within the 1756 ControlLogix automation platform. It occupies a single standard slot width in any ControlLogix chassis and draws backplane power efficiently. This module integrates seamlessly to provide reliable industrial networking capabilities.

What network communication speeds and physical ports does the Allen-Bradley 1756-ENET support?

The Allen-Bradley 1756-ENET supports standard 10 Mbps communication speeds over legacy Ethernet infrastructures. It features dual physical ports on the front faceplate, consisting of one standard RJ45 Ethernet port and one Attachment Unit Interface (AUI) port. These physical interfaces allow connectivity to both standard local area networks and older transceiver-based media.

How does the Allen-Bradley 1756-ENET handle data transfer and messaging?

The Allen-Bradley 1756-ENET handles both implicit messaging for real-time I/O control and explicit messaging for configuration, programming, and data transfer. It functions flexibly as either a scanner or an adapter on the network architecture. Additionally, it supports rack-optimized and direct connection methods to optimize controller backplane resource utilization.

What software is required to configure the Allen-Bradley 1756-ENET?

The Allen-Bradley 1756-ENET requires RSLinx and RSLogix 5000 software to properly configure its IP address and network parameters prior to runtime operation. System integrators must ensure power is removed from the ControlLogix chassis before performing physical installation or removal. Following proper configuration procedures ensures reliable controller-to-controller messaging and SCADA integration.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 16 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.