Siemens

Siemens 6GK5905-0PA00 | Siemens | SCALANCE KEY-PLUG XR-500 Layer 3

SKU 6GK5905-0PA00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6GK5905-0PA00

  • Country of origin:Germany

  • Product Type: CoMMunication Modules

  • Barcode: 85235190

  • Payment: T/T, Western Union

  • Weight: 30g

  • Dimensions: 12.00cm x 9.00cm x 1.00cm

  • Shipping port: Xiamen

  • Warranty: 12 months

The 6GK5905-0PA00 is a KEY-PLUG XR-500 Layer 3 removable data storage medium specifically designed for the Siemens SCALANCE XR-500 series of industrial switches. This module serves as a hardware key to enable advanced Layer 3 routing functionality on compatible devices while providing essential maintenance capabilities. It integrates the full range of C-plug functions, ensuring that device configuration and project data are securely stored for rapid recovery and simplified device replacement in the event of a system fault.

Features

  • Layer 3 Activation: Specifically designed to unlock Layer 3 routing features on SCALANCE XR-500 switches.
  • Simplified Maintenance: Integrates all standard C-plug functionality for plug-and-play device replacement.
  • Data Storage: Robust storage medium for retaining device configurations, ensuring seamless operational continuity.
  • Operational Efficiency: Minimizes downtime during hardware failure by allowing configuration data to be transferred instantly to a replacement unit.

Applications

  • Industrial network infrastructure requiring high-performance Layer 3 routing.
  • Infrastructure projects utilizing Siemens SCALANCE XR-500 modular switches.
  • Applications requiring strict configuration management and rapid disaster recovery protocols.
  • Industrial environments where minimizing Mean Time to Repair (MTTR) is critical.

Technical Specifications

Parameter Specification
Manufacturer Siemens
Model 6GK5905-0PA00
Product Type KEY-PLUG XR-500 Layer 3
Range SCALANCE
Product Phase Active
Dimensions 12.00 cm x 9.00 cm x 1.00 cm
Weight 0.03 kg
Commodity Code 85235190
Export Control (ECCN) 5A002

Installation Guidelines

  • Insertion: The KEY-PLUG should be inserted into the designated slot on the SCALANCE XR-500 switch. Ensure the device is powered down if required by the specific hardware manual before installation.
  • Configuration: Upon insertion, the switch will detect the plug. Ensure the firmware version of the switch is compatible with the Layer 3 features enabled by the key.
  • Data Backups: Regularly verify that the configuration stored on the plug is current to ensure that, in the event of a switch failure, the replacement unit is fully synchronized with the network requirements.
  • Handling: As a storage medium, handle the plug with care. Avoid exposing the contacts to static electricity, moisture, or extreme temperature fluctuations.

FAQ

What is the primary function of the 6GK5905-0PA00?

It is a removable storage medium used to enable Layer 3 routing features on the SCALANCE XR-500 series and to store configuration data for easy device replacement.

Does this module include C-plug functionality?

Yes, it contains all standard C-plug functions for configuration storage and simple device replacement in case of a fault.

What specific hardware range is this KEY-PLUG compatible with?

This module is designed specifically for the Siemens SCALANCE XR-500 product range.

How does the KEY-PLUG improve system availability?

By storing the device configuration, it allows an operator to move the plug to a replacement switch, enabling the new hardware to automatically adopt the previous unit's configuration.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...